//  Script generated by Search Maker Pro:

sQ1=new Array();sQ1[1]=new Array("http://www.actionair.co.uk/","Actionair - Fire / Smoke Dampers and Fancoils - Part of Ruskin Air Management Limited. Fire Dampers, VCD Dampers, Fan Coils, Fancoils, Dampers and Fancoils","Manufacturing Fire Dampers, Smoke Dampers, Air Control Dampers, Waterside Fan coil units, Airside Fancoil Units. Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control  and waterside control fan coil units through the pursuit of excellence. ","ALLAuthor: Garry Bryant Ruskin Air Management Limited - Website Developer");sQ1[2]=new Array("http://www.actionair.co.uk/mainframe.htm","Actionair - Part of Ruskin Air Management Limited","","");sQ1[3]=new Array("http://www.actionair.co.uk/right.html","Actionair - Dampers and Fancoils","Actionair, a manufacturer of Air Handling Products, including Smoke Dampers, Fire Dampers, Hot Dampers, Air Dampers, Energy Dampers, Trans Dampers, Vent Dampers, Fan coils, Hydropac and ActionPAC Control Systems.","Part of Ruskin Air Management Limited a member of the TOMKINS PLC group of companies. Demonstration: actionair Damper movement demonstration      Information About Us Actionair's exclusive product range includes fire/smoke dampers, air control dampers, control panels and fan coils. Dampers Actionair specialises in the design and manufacture of top quality fire, smoke and air control dampers.  News Portal  Update Click To View Click To View Click To View Case Studies Website last updated Enter Email to join our e-mailing list Click Here for more information  Fan Coils We offer horizontal and vertical mounted fan coil units, suitable for operation against moderate duct resistance. Latest Catalogues To be kept current with the latest product lines from Actionair please view our catalogue listings. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and airside and waterside control fan coil units through the pursuit of excellence. Terms &amp; Conditions of Sale | Terms &amp; Conditions of Purchase | ISO
    9001: 2008 | ISO 14001: 2004 Home | Sitemap | All Sitemaps | Search | Products | Catalogues | Contact Copyright © 2007 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l  ALLKeywords: damper, dampers, smoke damper, fire damper, industrial damper, marine damper, fan coil, coils, actionair, smoke, fire ,waterside fan coil, airside fan coil, Ventilation, hot, energy, access, air, trans, vent, actionpac, hydropac, snaplock, torque, control, system, control system, stainless, steel, aluminium, aerodynamic, blade, blades, galvanised, halogen free, lonmark, electro mechanical, multiplex, horizontal, vetical, square, rectangular, circular, flat, oval, duct, ductwork, high operating temperature, loss prevention council, fire tested, combination thermal activators, velocity systems, series aerofoil, series aeroseal, flanged casing, spigotted casing, airbalance, airstop, airtight, adjustable coated baffles, air conditioning, ventilation systems, ductwork systems, smoke management, low leakage, baffle grease filters, exhaust ventilation hood, access doors, proportional torque .");sQ1[4]=new Array("http://www.actionair.co.uk/sitemap.html","Actionair Site Map","","Actionair Site Map Please click the relevant section Home Page Links About Us Contact Us News Page Ruskin Air Management Limited Homepage Air Diffusion Homepage Naco Homepage Full Product Index Site Search Drawings Prices Recommended Spares Special Applications Fire &amp; Smoke Dampers Fire / Shield Damper Hot / Shield Damper Smoke / Shield PTC Damper Energy Shield Damper Series FB Curtain Fire Damper Trans Shield Damper mode 1 &amp; 2 Trans Shield Damper ACS Air Shield Damper A60 Marine Damper Air Shield Circulair Damper Industrial Tunnel Ventilation Dampers Fancoil Units Hydropac Hydropac EC Systempac Package Control Panels Actionpac EM Actionpac LNS Full Actionair Catalogue Directory (All Catalogues are in PDF Format) Hydropac Waterside Control Fan Coil Units Naco - Storm Louvres Industrial &amp; Tunnel Ventilation Dampers A - 60 Marine Fire Damper Fire / Shield Damper Smoke / Shield PTC Damper Hot / Shield Damper Air Shield Circular Energy / Shield Damper Air Shield Series FB Curtain Fire Dampers Trans / Shield Damper Trans / Shield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper Systempac Fan Coil Unit \\ Acoustic Flex \\ Diffuser System Package Actionpac EM Actionpac LNS Hydropac EC  Sales Regional Sales Managers UK Sales Area Map Charles Sillitoe - National Sales &amp; Marketing Manager Les Atkinson Trevor Bradley Keith Lander Dave Leek John Webber Sales International Sales Agents Index Map Graham Cooper - International Sales Austria Republic Of Slovenia Denmark Norway Netherlands Sweden Portugal Switzerland Belgium Luxenbourg Turkey United Arab Emirates Poland Hong Kong Bahrain Singapore Oman Malaysia South Korea Qatar Cyprus Greece Italy Lebanon Egypt Republic Of Ireland Spain Romania Nigeria Ruskin (United States) Link Partners Tomkins Air System Components Ruskin Hevac &amp; FETA LPCB Loss Prevention Certification Board Ship Technology - Marine Dampers - Ship Industry Airport Technology - Airport Industry LonWorks Control System Building Design Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[5]=new Array("http://www.actionair.co.uk/install.html","Actionair ProductInstallations","","Home Installations Installations Please select your required category: Currently comprising of the 'SmokeShield/HotShield installation guide' (BSEN13662/BSEN13501-3)  Drawings BS 476     Non standard application  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[6]=new Array("http://www.actionair.co.uk/contact.htm","Actionair - Contact Details","","Home Contact us - Dampers &amp; Fancoils Actionair, Joseph Wilson Ind. Estate, South Street, Whitstable, Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Web site: www.actionair.co.uk Location Map (Printable) Please click here Image produced from the Ordnance Survey Get-a-map service. Image reproduced with kind permission of Ordnance Survey and Ordnance Survey of Northern Ireland.  Customer Contact Form If you have any enquiries please feel free to use our contact form and we will respond to you as soon as possible. Many thanks Actionair  Contact Job title Company Address Country Post Code Telephone Fax Email   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Products | Catalogues | Contact Copyright Â© 2004 actionair. All Rights Reserved Minimum system requirements | Lega l");sQ1[7]=new Array("http://www.actionair.co.uk/a60damp.html","Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects","","Home Products Actionair A60 marine fire damper Marine Fire Dampers Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3. Tested and approved for class A-60 divisions (bulkheads and decks) Complies to Marine Equipment Directive 96/98/EC. USCG-EU MRA   Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects Actionair has, for many years, been associated in the design, development and manufacture of life safety equipment, including the supply of fire damper products to the offshore and marine industry. The Actionair A-60 Fire Damper has been specifically engineered to meet stringent legislation. The A-60 Marine Fire Damper compliments the comprehensive range of automatic fire and smoke dampers and associated controls, provides the complete solution for shipboard air conditioning and ventilation systems fire safety engineering strategies. Application The A-60 Marine Fire Damper has been designed for inclusion in air conditioning and ventilation systems and is tested and approved for fitting to class A-60 divisions (bulkheads and decks). The A-60 dampers can be used where the maximum system pressure is up to 1500 Pa and duct velocities to 15m/s. A-60 Marine Fire Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions please refer to Actionair Technical Sales Office.  Electrical Catalogue The A-60 Marine Fire Damper is suitable for both vertical and horizontal applications, with airflow in either direction. The dampers which are A60 fire rated to IMO Fire Test procedures Code, Annex 1 Pt 3, are normally open, and fail-safe to the closed position. Fail-safe is by means of a unique and patented Electrical Thermal Release (ETR) which operates at 72 &deg;C, or if power supply is interrupted. The ETR incorporates a safety feature, including that ensures the fail-safe status of the damper if the ETR is not fitted on to the ductwork. A manual test switch allows periodic operation of the 2 A-60 Marine Fire Dampers. The associated electrical control modes are available in 24 Volt, 120 Volt or 230 Volt versions.  (View Catalogue) All Catalogues  Marine Applications Information Page  A60 FLA hole and DHP.xlt (Microsoft Excel Document. Right click 'Save target as' to download) 769 kb This file is to compliment what's in the A60 catalogue. Because all damper sizes are different, finding the start dim for the flange holes is tricky. Often, customers need this in advance so they can order mating flanges to suit our dampers. Also the position of the actuator shifts up and down the side of the damper dependant upon height. It is not just in the centre! DHP supplies this info. Other info, such as no of blades and free area has been asked for so this has been added. Corrosion tested to BS EN 60068-2-52, Severity 2 conditions. Vibration tested to BS EN 60068-2-6 (5Hz &#8211; 350Hz @ 2g). 40mm flanged style casing in rectangular or circular format. Fire/Shield Fire Damper  Pneumatic  Fail-safe is by means of a Pneumatic Thermal Release (PTR) which operates at 74 &deg;C, or if air supply is interrupted. For more information including dimensional and installation data please view the 12 page A-60 Marine Fire Damper   Specification for A60 MARINE FIRE DAMPERS The Actionair A-60 Marine Fire Damper is constructed from galvanised steel 1.2mm thick, 40mm flanged rectangular or circular casing, (316 stainless steel option available). 75mm interlocking 430 grade stainless steel aerodynamic blades, steel blade end bearings and 300 grade stainless steel peripheral gasketting. (316 grade stainless steel blade and blade end bearing available). The totally enclosed precise movement opposed blade drive is positioned out of the airstream for protection against damage, and is hard wearing and free running. Electrical The Actionair direct-coupled spring return fail-safe electrical control modes are fitted with halogen free low smoke and fume electrical cable. They have a 60 second reset time and a 20 second release time. Each actuator has a 72°C rated electrical thermal release (ETR). The ETR incorporates a safety electrical interlock that only permits actuator operation when correctly fitted. A green ‘Healthy’ indication lamp is built into the ETR housing to give a simple and clear visual check that the actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. A manual test switch allowing periodic operation of the damper for testing purposes simulates actual fail-safe release under smoke/fire conditions. End switches are provided with each mode for reset and release monitoring. Pneumatic The Actionair direct coupled spring return fail-safe pneumatic control mode requires an air pressure of between 5 to 8 bar (72 to116 psi) to operate. They have 3 second reset and release time. Each actuator has a pneumatic thermal release (PTR). The PTR assembly is supplied with 500mm nylon tubing that connects to the quick fit couplings of the PTR and actuator. Incorporated is a failsafe 74°C fusible link. When this operates, air exhausts from the actuator, permitting the spring return actuator to go to the failsafe position, thus closing the damper. Switch box and solenoid accessories are available for monitoring and control. Document downloads and approval list (File format PDF) A-60 Marine  - Catalogue A-60 Marine Fire Damper - Installation, Operating & Maintenance Instructions A-60 Marine Pneumatic Fire Damper - Installation, Operating & Maintenance Instructions Germanischer Lloyds 43 316-02 HH expires March 2011 Type Approval Cert MED 0750118 (Module B) expires 12 June 2012 SAS F070145 Cert of Fire Approval expires 12 June 2012   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2008 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[8]=new Array("http://www.actionair.co.uk/ascdamp.html","Actionair SERIES CIRCULAIR/BALANCE CIRCULAR AIR BALANCING DAMPERS","","Home Products Actionair Circulair - Circular air balancing dampers Circulair Dampers Manual Control   Actionair CIRCULAIR CIRCULAR AIR BALANCING DAMPERS Specification for CIRCULAIR DAMPERS Actionair Circulair Air Balancing Dampers comprise of a single 1.2 mm galvanised steel blade housed within a 0.8 mm galvanised steel casing. Complete with Manual Control. Casing leakage conforms to HVCA ductwork specification DW144 Class C up to 1000 Pa. Damper spigots conform to BSEN1506. Manual control. Extended bracket to suit insulated ducts. Common casing depth of 200mm. Eurovent duct sizes: 100-355mm dia. Stock Item. Please click here to copy the specification to your clipboard ready to paste into your project specification.     Sizes Catalogue SIZES AVAILABLE (DIA): 100mm, 125mm, 150mm, 160mm, 200mm, 250mm, 300mm, 315mm, 350mm, 355mm For more information including dimensional and installation data please view the 2 page Circulair / Balance Damper  (View Catalogue) All Catalogues   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2008 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[9]=new Array("http://www.actionair.co.uk/about.html","About Actionair","","Actionair - Fire / Smoke Dampers and Fancoils Actionair with 30 years of market experience is acknowledged as UK market leader in the manufacture of top quality fire, smoke and air control dampers and waterside control fan coil units, serving buildings in Britain and throughout the world. A continuous programme of research, development and testing is maintained to originate the new products which will join our proven range and maintain our market lead in both Technology and Customer Service. The leading brand divisions of Actionair, Air Diffusion and Naco, form Ruskin Air Management Limited. With our associate company Ruskin (USA), we provide unrivalled design and development expertise in ventilation, air distribution, smoke control and screening systems. Each division offers a high level of customer service, supported by the strength of the Ruskin organisation worldwide.  The Production area at Whitstable is 44,000 sq ft Actionair South Street Whitstable Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[10]=new Array("http://www.actionair.co.uk/hydro.html","Actionair Hydropac Heavy Duty Air Control and Shut-off Dampers PHW230 and PHW170 Series","Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke     control  and waterside control fan coil units through the pursuit of excellence.","Home Products Actionair Hydropac - Waterside control fan coil units Fully insulated with Class &#8216;O&#8217; open cell thermal and acoustic foam. Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic and thermal insulation. Various filter options. Outputs available up to 6.4kW cooling and 6.9kW heating.   Actionair Hydropac Waterside control fan coil units - 170mm &amp; 230mm Deep Actionair Hydropac horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure Temperature control is by means of modulating 4 &#8211; port diverting valves on heating and cooling, operated via stand alone or BMS temperature controller and room or return air sensor. Designated &#8216;PHW&#8217;, the series consists of standard 230mm deep and slimline 170mm deep versions. For more information including dimensional and installation data please view the 12 page Hydropac Catalogue  Construction Hydropac Catalogue Specification for HYDROPAC Chassis Manufactured from 1.2mm galvanised sheet steel with 1.6mm fan decks and back plates. The chassis shall incorporate recessed, slotted mounting points for drop-rods. An integral acoustically lined discharge plenum fitted with spun steel spigots and insulated blanking plates. Access Access to fans shall be via an insulated bottom panel with keyhole slots. Insulation 100Kg/m3 density, class &#8216;O&#8217; CFC and HFC free open cell foam shall be utilised for both thermal acoustic insulation. Fans/Motors Fan/motor shall be permanent split capacitor external rotor ,forward curved centrifugal type, with high efficiency, low noise multiblade galvanised sheet steel impellers. Electrical supply shall be 230V 1ph 50Hz. Speed Control Speed control shall be by means of a multi-tapped transformer giving eleven settings. A panel mounted three speed switch with additional Fine adjustment. On/off control to fans shall be by means of a panel mounted illuminated two position switch. Coils Coil matrix blocks shall be copper with aluminium fins. Fitted with vents and drains as standard Condensate Tray Condensate trays shall be synthetically treated, galvanised sheet steel, foam insulated. A positive fall to drain shall be provided with 3/4&quot; B.S.P. female bottom connection. Filters Filters shall be washable EU3, continuous filament media. Please click here to copy the specification to your clipboard ready to paste into your project specification. Click to see Actionair Fancoil i-drop library and drop drawings into your Autodesk application with &#8220;Download idrop indicator&#8221; To learn more about i-drop technology click here.  (View Catalogue) All Catalogues    Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[11]=new Array("http://www.actionair.co.uk/cpd.html","CPD Seminars","","Home Actionair CPD Seminars Actionair CPD Seminars &quot;An introduction to smoke and fire control in ventilation systems&quot; targeted at Mechanical Engineers, Building Services Engineers and Electrical Engineers that are either recently qualified or new to this area. The main areas covered are: &middot; Use of Fire Dampers and their limitations &middot; Benefits and use of Smoke Dampers &middot; BS476 Part 20 &middot; Building Research Establishment test 2005 &middot; Approved Doc B regulations anticipated for 2007 &middot; BS5588 Part 9 &middot; Control Methods associated with the use of Dampers &middot; Brief animation of typical scenario. Contact Andrew Collard for more information. Telephone: 07884 184061 Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2007 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[12]=new Array("http://www.actionair.co.uk/FishingWriteUp.pdf","Microsoft Word - FiSHING WRITEUP.doc","","Martyn Park Wins the Dave Lowe Memorial Trophy. The Fifteenth Actionair Big Fish Day By John Webber The fifteenth annual big fish day held on the 27 of October was again blessed with good weather and huge fish. This annual event for Actionair, with invited guests of consultants and contractors from within the H,V,A,C industry lived up to its name with a winning fish a rainbow trout of over seventeen pounds, and nine fish over ten pounds. Over thirty guests turned out for this event, some good anglers, some who had never picked up a fly fishing rod before. This year as before the event was held at Narborough Lakes near Kings Lynn in Norfolk, where Ray, Jan, Jay and Chris, who own and run the fishery, made sure the venue and the fish were in top condition. The weather conditions on the day before the event had me a little worried, but anyone reading this, who has attended this event in the past will know that this isn't an uncommon position for me to be in, but as always I needn't have worried, on the morning of the big fish day the sky cleared and we had a dry pleasant winters day. Reg Petch, the fly casting instructor this year took six novices under his wing, and once again had most of them fishing on their own by lunchtime, that takes some doing, and I am sure some of these guys will be back next year ready to try again. The fishing this year was hard because of the bright and still conditions, but it didn't stop Martyn Park hooking a 17lb 4oz rainbow trout, that took a lot of skill and patience to land, in second place with a rainbow of 16lb 12oz was someone who wanted to remain nameless, because as he organises the event, and is often accused by friends and colleagues of having inside information on the whereabouts of the biggest fish, and of course I do. Like the rest of you I am looking forward to next year and I hope to see you all, and some more new faces. th The One That Didn't Get Away");sQ1[13]=new Array("http://www.actionair.co.uk/pdf/Hospitals.pdf","Hospital_Flyer Art.qxd","","When it comes to fire and smoke safety in hospital ventilation systems there is one company which has a proven track record... Actionair Smoke/Fire Dam p ers and Control Systems Actionpac LNS3 Intelligent Damper Control Actionair have been the market leaders in this area of life safety offering a complete solution in their market leading Smoke/Shield dampers combined with the Actionpac intelligent damper control and monitoring system. This combination offers both the Consulting Engineer and the Hospital facility manager alike a comprehensive solution to the complex control requirements of modern fire safety strategies and a user friendly tool for monitoring and regular testing of smoke / fire dampers. It ensures damper reliability and functionality throughout the life span of a Hospital building. The Actionpac damper control and monitoring system incorporates a graphical user interface providing live status of all activities with complete clarity of information. With over 100 projects successfully undertaken, Actionair have built up a wealth of Hospital specific understanding and practical experience which has been incorporated into Actionpac's continuous product development programme insuring Actionpac will continue to meet and anticipate the trends and demands of the future. and Monitoring System then be established/extinguished and only as a last resort building occupants can be moved or sideways evacuated away from the affected areas. This containment strategy enables the remainder of the building to be kept `Operational' and with minimal disturbance to patients, staff and the critical work of a busy Hospital. Actionpac Unlike conventional control systems Actionpac is unique in that it has practically unlimited capacity to accommodate high numbers of dampers and the complexity of `cause and effect' scenarios common to hospital projects. Being PC based it can also easily handle 11th hour changes such as additional damper numbers, zones, inputs /outputs, strategies etc, from the PC on site to additional programming required. Routine testing Intelligent control is also a critical feature during routine testing, which is now becoming an increasingly important issue, with BS5588 and various insurance bodies strongly recommending six-monthly testing of all dampers. As yet, these are only recommendations; however, new EU legislation currently being prepared will demand frequent testing and certification of all `life safety' dampers. Without an intelligent control and monitoring system, this will prove to be an extremely costly, disruptive and laborious ask for building and safety managers. Given the potentially fatal consequences of a damper failing to close in the event of a fire, or indeed open to provide smoke extraction, Actionair has always promoted the concept of regular testing to ensure proper damper functionality and has made provision for scheduled, automatic damper testing and logging on the Actionpac system. Actionair Smoke/Shield PTC Proportional Torque Control Automatic Smoke and Fire Dampers Intelligent Damper Control It is common knowledge that in the event of a fire detection, ventilation shut down and building evacuation is not an option for a hospital, or at least not until all other options have been exhausted. It can be difficult, dangerous and even fatal to attempt to move or evacuate patients and is only considered in extreme cases. It is therefore essential that the intelligent control of dampers to initially contain and control the spread of smoke and fire be used. The source and extent of the fire can Actionair offer the following Damper Interfaces: Damper interface application SFDI Smoke Fire Motorised spring return for smoke containment / extraction Balanced motorised spring return for smoke extraction Motorised on / off for smoke containment / extraction Electrical release or monitoring only for fire containment 300 °C for 1 hour for smoke containment / extraction Examples of Hospital projects and others with Actionpac Systems Darent Valley, Dartford Royal Gwent Hospital, Wales Neptune Building, London 3PDI 3 Position SDI ­ Smoke Neville Hall Hospital, Scotland Chorlton New Mill, Chorley FDI ­ Fire Rutland Gate, London Royal Free Hospital, London HDI ­ Hot Air Traffic Control, Shannon James Street Apartments, Dublin Standards Actionair dampers are fully compliant with the latest Inter national, European and BS standards (ISO10294-1, EN1366-2 and BS ISO 10294-1) and the old BS standard BS476 part 20 and are lPCB approved (Loss Prevention Certification Board) meaning 3rd party regular reassessment / audit testing to ensure quality of product and service are maintained. Actionpac damper control and monitoring system is CE approved and already meets the proposed new draft BS EN 12101-9 standard for smoke and heat control systems. Office of Public Works, Dublin Nine Wells Hospital, Dundee Dublin Airport, Dublin Mary's Abbey, Dublin Regional Hospital, Limerick European Justice Court, Luxembourg British Museum, London 41 Lothbury (Office Block), London John Radcliffe Hospital, UK Finsbury Square (Office Block), London Prince Philip Hospital, Leeds General Hospital, Southampton R.A.F. Mildenhall, Suffolk 140 Aldersgate (Office Block), London no compromise... FOR FURTHER INFORMATION PLEASE CONTACT: Queen Elizabeth Hospital, Gateshead Dexia Bill, Luxumberg UCC Medical Nursing, Cork HSB Bootle, Liverpool Western Hospital, Scotland University Hospital, Southhampton Andrew Collard, Actionpac Product Manager Ruskin Air Management Ltd, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[14]=new Array("http://www.actionair.co.uk/catalogues.htm","Actionair - Online Product Catalogues","","Home Products Actionair Catalogues Catalogues are in PDF format. Adobe Acrobat PDF Reader can be downloaded from the following link at Adobe.com . The catalogues can either be viewed online by clicking the required catalogue or downloaded by clicking the right mouse key on the required catalogue and selecting SAVE TARGET AS! to save to your desktop for offline viewing. If you don't have Acrobat reader you can view the catalogues as a web page by clicking on the WEBPAGE version. New Actionair Catalogues: HT VCD MB120 High Temperature Volume Control Damper Fire / Shield Damper Smoke/Shield PTC Acrobat (PDF) Version PDF Download Size = 200kb Acrobat (PDF) Version PDF Download Size = 176kb Acrobat (PDF) Version PDF Download Size = 303kb    A60 Marine Fire Damper CSS Damper CSS Smoke ES Rated Fire Damper Circulair Damper Acrobat (PDF) Version PDF Download Size = 384kb Acrobat (PDF) Version PDF Download Size = 693kb Acrobat (PDF) Version PDF Download Size = 905kb    Hot/Shield PTC PTC Control Modes and Ancillaries Air/Shield Control &amp; Shut Off Dampers Acrobat (PDF) Version PDF Download Size = 514kb Acrobat (PDF) Version PDF Download Size = 231kb Acrobat (PDF) Version PDF Download Size = 224kb    Hydropac Trans/Shield Modes 1&amp;2 Trans/Shield ACS Acrobat (PDF) Version PDF Download Size = 176kb Acrobat (PDF) Version PDF Download Size = 176kb Acrobat (PDF) Version PDF Download Size = 235kb    New Actionpac LNS * New Actionpac 60 and 120 Cost Competitive Intelligent Damper Control and Monitoring System Actionpac EMS &amp; EMB Acrobat (PDF) Version PDF Download Size = 282kb Acrobat (PDF) Version PDF Download Size = 466kb Acrobat (PDF) Version PDF Download Size = 142kb    Systempac  Energy/Shield ES Air Control and Shut-off Dampers Ruskin Industrial Dampers Acrobat (PDF) Version PDF Download Size = 176kb Acrobat (PDF) Version PDF Download Size = 814kb Acrobat (PDF) Version PDF Download Size = 235kb    New M5-3P-CMS New Hot/Shield Damper Interface Enclosure (HDI) DWFX-F Installation Guide For Existing Dry Stud Partition Walls Acrobat (PDF) Version PDF Download Size = 115kb Acrobat (PDF) Version PDF Download Size = 368kb Acrobat (PDF) Version PDF Download Size = 375kb    Actionair DWFX DRY WALL FIX Installation System Actionair Access/Shield Removable Access Doors Pressure Relief Flaps Models D-PRF and G-PRF Acrobat (PDF) Version PDF Download Size = 148kb Acrobat (PDF) Version PDF Download Size = 117kb Acrobat (PDF) Version PDF Download Size = 365kb     Storm Louvre     Acrobat (PDF) Version PDF Download Size = 305kb    If would like to request any literature then please tick the relevant catalogue and fill in your details. Fire / Shield Systempac Smoke/Shield PTC Fan Coils Hydropac  Hot/Shield PTC A60 Marine Fire Damper Energy / Shield Trans/Shield Modes 1&amp;2 Ruskin Industrial Dampers Trans/Shield ACS Storm Louvre Circulair Damper Actionpac LNS CSS Damper Air/Shield Control &amp; Shut Off Dampers Actionpac EMS &amp; EMB Series FB Curtain Fire Damper Contact Job title Company Address Country Post Code Telephone Fax E-Mail Project Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2007 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[15]=new Array("http://www.actionair.co.uk/maillistinfo.html","Mailing List Information","","Mailing List Information As part of our continuing effort to keep our customers updated subscribers to the Actionair mailing list will receive frequent updates on new catalogues, drawings, technical information and company related news. If you have been subscribed by mistake or wish to unsubscribe then please email Site Administrator to be removed. Our Website Policy: We do not collect personal information without your knowledge and permission, nor do we resell or distribute any site visitor data, including information that may be collected as a natural by-product of your visit. Collection and use of technical information: The Actionair Web site may use cookies in order to provide a better experience, these are temporary &quot;session&quot; cookies which enable a visitor&#8217;s web browser to remember which pages on this website have already been visited. Visitors can use this website with no loss of functionality if cookies are disabled from the web browser. Technical details in connection with visits to this website are logged by our internet service provider (BTOpenWorld, trading as &quot;British Telecommunications PLC&quot;) for our statistical purposes. No information is collected that could be used by us to identify website visitors. The technical details logged are confined to the following items: &middot; The IP address of the visitor&#8217;s web server &middot; The top-level domain name used (for example .ie, .com, .org, .net) &middot; The previous website address from which the visitor reached us, including any search terms used &middot; Clickstream data which shows the traffic of visitors around our websites (for example pages accessed and documents downloaded) &middot; The type of web browser used by the website visitor. Ruskin Air Management Limited will make no attempt to identify individual visitors, or to associate the technical details listed above with any individual. It is the policy of Ruskin Air Management Limited never to disclose such technical information in respect of individual website visitors to any third party (apart from our internet service provider, which records such data on our behalf and which is bound by confidentiality provisions in this regard), unless obliged to disclose such information by a rule of law. The technical information will be used only by Ruskin Air Management Limited, and only for statistical and other administrative purposes. You should note that technical details, which we cannot associate with any identifiable individual, do not constitute &quot;personal data&quot; for the purposes of the Data Protection Act, 1988 If you have any questions about our policy, please contact our Site Administrator. To contact Actionair. Mail: Actionair South Street Whitstable Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Email Site Administrator Our Mission Air Diffusion as part of Ruskin is committed to leading the HVAC industry with innovative air control products and unrivaled quality that exceed customer expectations through the continuous pursuit of excellence. Home | Products | Catalogues | Contact Copyright © 2004 AirDiffusion. All Rights Reserved RAM | Actionair | Naco | Minimum system requirements | Lega l");sQ1[16]=new Array("http://www.actionair.co.uk/search.html","Search this Site","","Search the Actionair site:   The search engine will find pages on this website only. For best results enter just one or two words. Searches on more than one word will be treated &quot;as a phrase&quot;. Use the asterisk (*) character for wildcard searches.  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2005 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Legal");sQ1[17]=new Array("http://www.actionair.co.uk/products.html","Product Listings for Actionair - Dampers and Fancoils - Part of Ruskin Air Management Limited","","Home Products Full Actionair Product List  DAMPERS   &nbsp&nbsp&nbsp FIRE / SHIELD DAMPER Stainless Steel Bladed Curtain Fire Dampers Series &nbsp&nbsp&nbsp HOT / SHIELD DAMPER High operating temperature smoke management and fire dampers &nbsp&nbsp&nbsp SMOKE SHIELD PTC Proportional Torque Control - Automatic Smoke and Fire Dampers &nbsp&nbsp&nbsp CSS SMOKE ES RATED FIRE DAMPER CSS Smoke ES Rated Fire Damper &nbsp&nbsp&nbsp SERIES FB CURTAIN FIRE DAMPER Galvanised steel bladed curtain fire dampers &nbsp&nbsp&nbsp TRANS SHIELD DAMPER Modes 1 &amp; 2 Transfer Stainless Steel Sliding Plate Fire and Smoke Dampers &nbsp&nbsp &nbspTRANS SHIELD DAMPER Modes ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper &nbsp&nbsp&nbsp AIR SHIELD DAMPER Control and Shut Off Dampers &nbsp&nbsp&nbsp ENERGY SHIELD DAMPER Air Control and Shut-off Dampers &nbsp&nbsp&nbsp A60 MARINE DAMPER Marine Fire Dampers &nbsp&nbsp HT VCD MB120 High Temperature Volume Control Damper &nbsp&nbsp&nbsp CIRCULAIR DAMPER Circulair Air Balancing Dampers &nbsp&nbsp&nbsp RUSKIN TUNNEL VENTILATION DAMPERS Heavy Duty Steel and Fibreglass Dampers    FAN COIL UNITS   &nbsp&nbsp&nbsp HYDROPAC Waterside control fan coil units - 170mm &amp; 230mm Deep &nbsp&nbsp&nbsp SYSTEMPAC Fan coil unit / acoustic flex / diffuser system package     CONTROL PANELS  &nbsp&nbsp&nbsp ACTIONPAC EM &amp; EMB Electro &#8211; Mechanical control and monitoring system &nbsp&nbsp&nbsp ACTIONPAC EM Electro &#8211; Mechanical control and monitoring system &nbsp&nbsp&nbsp ACTIONPAC LNS Intelligent smoke and fire damper control systems Recommended Spares Lists All recommended spares documents are available in Microsoft Word format allowing you to add your details. To save the file to your computer, right click on the relevant link and then click 'Save Target As': RECOMMENDED SPARES LETTER AIR SHIELD RECOMMENDED SPARES LIST EMB PANELS RECOMMENDED SPARES LIST EMS PANELS RECOMMENDED SPARES LIST FIRE SHIELD RECOMMENDED SPARES LIST SMOKE SHIELD RECOMMENDED SPARES LIST TRS ACS RECOMMENDED SPARES LIST TRS M1 &amp; 2 RECOMMENDED SPARES LIST   SWIMMING POOL APPLICATIONS Please Note: - Actionair dampers are not suitable for Swimming Pools or associated areas treated with either chlorine or ozone. Dampers will only be supplied upon written instructions and with the knowledge that any guarantee will be invalid. Should Dampers be supplied under these conditions for Swimming Pools or associated areas, a regular maintenance programme should be implemented. This should consist of a visual inspection of damper blades and casings, cleaning and spraying of a light machine oil to the exposed areas that will come into contact with the contaminated air. The above maintenance programme is no guarantee that the damper life expectancy will be extended. Whilst we cannot guarantee the performance of our standard damper manufacture, 316 grade Austenitic stainless steel will provide the highest protection. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[18]=new Array("http://www.actionair.co.uk/copyright.html","Copyright","","Copyright Notice All material on this domain (naco.co.uk) is copyrighted by a Division of Ruskin Management. All rights reserved. The trademarks, logos and service marks (&quot;Marks&quot;) displayed on the Site are the property of Actionair , Air Diffusion, Naco , Ruskin Air Management and other parties. Users are prohibited from using any Marks without the written permission of Actionair or such third party, which may own the Marks. All content on the Site is protected by copyright. Users are prohibited from modifying, copying, distributing, transmitting, displaying, publishing, selling, licensing, creating derivative works or using any content (including images,flash demonstrations, PDF files) on the Site for commercial or public purposes. To contact Actionair. Mail: Actionair South Street Whitstable Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Email Site Administrator Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[19]=new Array("http://www.actionair.co.uk/minsys.html","System Requirements","","We recommend that use either Microsoft Internet Explorer (version 4 or higher) or Netscape Navigator (Version 4 or higher). To view content on our online product catalogue we also recommend that you have JavaScript enabled in your browser and that you use Adobe Acrobat to read PDF files. To view Macromedia Flash Content on the site we recommend downloading the latest Flash player from Macromedia. If you are having any difficulty with any piece of the site then please do not hesitate to contact us for assistance. Thank You, Actionair, Web Site Administrator Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[20]=new Array("http://www.actionair.co.uk/legal.html","Legal Notice from Actionair","","Legal The New symbol alerts people to the fact that their information is being collected, and directs them to sources, which will clearly explain how their information is to be used. Our Website Policy: We do not collect personal information without your knowledge and permission, nor do we resell or distribute any site visitor data, including information that may be collected as a natural by-product of your visit. Collection and use of technical information: The Actionair Web site may use cookies in order to provide a better experience, these are temporary &quot;session&quot; cookies which enable a visitor&#8217;s web browser to remember which pages on this website have already been visited. Visitors can use this website with no loss of functionality if cookies are disabled from the web browser. Technical details in connection with visits to this website are logged by our internet service provider (BTOpenWorld, trading as &quot;British Telecommunications PLC&quot;) for our statistical purposes. No information is collected that could be used by us to identify website visitors. The technical details logged are confined to the following items: &middot; The IP address of the visitor&#8217;s web server &middot; The top-level domain name used (for example .ie, .com, .org, .net) &middot; The previous website address from which the visitor reached us, including any search terms used &middot; Clickstream data which shows the traffic of visitors around our websites (for example pages accessed and documents downloaded) &middot; The type of web browser used by the website visitor. Ruskin Air Management Limited will make no attempt to identify individual visitors, or to associate the technical details listed above with any individual. It is the policy of Ruskin Air Management Limited never to disclose such technical information in respect of individual website visitors to any third party (apart from our internet service provider, which records such data on our behalf and which is bound by confidentiality provisions in this regard), unless obliged to disclose such information by a rule of law. The technical information will be used only by Ruskin Air Management Limited, and only for statistical and other administrative purposes. You should note that technical details, which we cannot associate with any identifiable individual, do not constitute &quot;personal data&quot; for the purposes of the Data Protection Act, 1988 If you have any questions about our policy, please contact our Site Administrator. To contact Actionair. Mail: Actionair, Joseph Wilson Ind. Estate, Whitstable, WV15 5BB Kent, CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Email Site Administrator Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[21]=new Array("http://www.actionair.co.uk/sales.html","Actionair Sales Areas Location Map","","Home Actionair Sales Representation        Actionair Sales Office, Joseph Wilson Ind. Estate, South Street, Whitstable, Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk National Sales &amp; Marketing Manager CHARLES SHILLITOE Mobile : 07710 601520  International Sales GRAHAM COOPER Mobile : 07710 601515     Regional Sales Managers  JOHN WEBBER Mobile : 07710 601526 TERRY SWEET Mobile : 07903 862097 TREVOR BRADLEY Office : 07710 601527 KEITH LANDER Mobile : 07710 601524 LES ATKINSON Mobile: 0771 0601523 DAVE LEEK Mobile : 07710 601530    Fan Coil Product Manager  Control Panel Product Manager  UK Agents  TROY CHAMBERS Mobile: 07710 601519 ANDREW COLLARD Mobile: 07884 184061 MORISON &amp; MILLER SCOTLAND TEL: 0141 6470825 DUCT PRODUCTS NORTHERN IRELAND TEL : 02891 471121  Sales Web Mail ALLAN AGATE EMPHASIS ON GLASS LOUVRES MOBILE : 07970 231644&quot; alt=&quot;Mike Warnock EMPHASIS ON METAL LOUVRES MOBILE : 07970 231650 ALLAN AGATE EMPHASIS ON GLASS LOUVRES MOBILE : 07970 231644&quot; &gt; Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2008 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Legal  ALL");sQ1[22]=new Array("http://www.actionair.co.uk/ror.xml","ROR Sitemap for http://www.actionair.co.uk/","","http://www.actionair.co.uk/ http://www.actionair.co.uk/ sitemap SiteMap http://www.actionair.co.uk/ week 0 sitemap http://www.actionair.co.uk/right.html week 0 sitemap http://www.actionair.co.uk/links.html week 0 sitemap http://www.actionair.co.uk/about.html week 0 sitemap http://www.actionair.co.uk/contact.htm week 0 sitemap http://www.actionair.co.uk/newspage.htm week 0 sitemap http://www.actionair.co.uk/search.html week 0 sitemap http://www.actionair.co.uk/drawing.html week 0 sitemap http://www.actionair.co.uk/prices.html week 0 sitemap http://www.actionair.co.uk/spares.html week 0 sitemap http://www.actionair.co.uk/applications.html week 0 sitemap http://www.actionair.co.uk/fsdamp.html week 0 sitemap http://www.actionair.co.uk/hsdamp.html week 0 sitemap http://www.actionair.co.uk/newredcatalogues/SmokeShield.pdf week 0 sitemap http://www.actionair.co.uk/pdf/energy.pdf week 0 sitemap http://www.actionair.co.uk/pdf/fbseries1.pdf week 0 sitemap http://www.actionair.co.uk/pdf/trans.pdf week 0 sitemap http://www.actionair.co.uk/pdf/transacs.pdf week 0 sitemap http://www.actionair.co.uk/pdf/air.pdf week 0 sitemap http://www.actionair.co.uk/pdf/marine.pdf week 0 sitemap http://www.actionair.co.uk/pdf/AirShieldCircular.pdf week 0 sitemap http://www.actionair.co.uk/pdf/industrial.pdf week 0 sitemap http://www.actionair.co.uk/pdf/hydropac.pdf week 0 sitemap http://www.actionair.co.uk/Hydropac EC.html week 0 sitemap http://www.actionair.co.uk/syspack.html week 0 sitemap http://www.actionair.co.uk/pdf/Actionpacem.pdf week 0 sitemap http://www.actionair.co.uk/pdf/ActionpacLNS.pdf week 0 sitemap http://www.actionair.co.uk/catalogues.htm week 0 sitemap http://www.actionair.co.uk/pdf/storm.PDF week 0 sitemap http://www.actionair.co.uk/pdf/fire.pdf week 0 sitemap http://www.actionair.co.uk/newredcatalogues/HotShield.pdf week 0 sitemap http://www.actionair.co.uk/pdf/fancoils.pdf week 0 sitemap http://www.actionair.co.uk/pdf/systempac.pdf week 0 sitemap http://www.actionair.co.uk/sales.html week 0 sitemap http://www.actionair.co.uk/la.html week 0 sitemap http://www.actionair.co.uk/tb.html week 0 sitemap http://www.actionair.co.uk/kl.html week 0 sitemap http://www.actionair.co.uk/dl.html week 0 sitemap http://www.actionair.co.uk/jw.html week 0 sitemap http://www.actionair.co.uk/ts.html week 0 sitemap http://www.actionair.co.uk/uksales.html week 0 sitemap http://www.actionair.co.uk/intersales.html week 0 sitemap http://www.actionair.co.uk/gc.html week 0 sitemap http://www.actionair.co.uk/int8.htm week 0 sitemap http://www.actionair.co.uk/int3.htm week 0 sitemap http://www.actionair.co.uk/int4.htm week 0 sitemap http://www.actionair.co.uk/int5.htm week 0 sitemap http://www.actionair.co.uk/int6.htm week 0 sitemap http://www.actionair.co.uk/int7.htm week 0 sitemap http://www.actionair.co.uk/int9.htm week 0 sitemap http://www.actionair.co.uk/int10.htm week 0 sitemap http://www.actionair.co.uk/int11.htm week 0 sitemap http://www.actionair.co.uk/int12.htm week 0 sitemap http://www.actionair.co.uk/int13.htm week 0 sitemap http://www.actionair.co.uk/int14.htm week 0 sitemap http://www.actionair.co.uk/int15.htm week 0 sitemap http://www.actionair.co.uk/int16.htm week 0 sitemap http://www.actionair.co.uk/int17.htm week 0 sitemap http://www.actionair.co.uk/int18.htm week 0 sitemap http://www.actionair.co.uk/int19.htm week 0 sitemap http://www.actionair.co.uk/int20.htm week 0 sitemap http://www.actionair.co.uk/int21.htm week 0 sitemap http://www.actionair.co.uk/int22.htm week 0 sitemap http://www.actionair.co.uk/int23.htm week 0 sitemap http://www.actionair.co.uk/int24.htm week 0 sitemap http://www.actionair.co.uk/int25.htm week 0 sitemap http://www.actionair.co.uk/int26.htm week 0 sitemap http://www.actionair.co.uk/int2.htm week 0 sitemap http://www.actionair.co.uk/int27.htm week 0 sitemap http://www.actionair.co.uk/int29.htm week 0 sitemap http://www.actionair.co.uk/int31.htm week 0 sitemap http://www.actionair.co.uk/style.css week 0 sitemap http://www.actionair.co.uk/ror.xml week 1 sitemap http://www.actionair.co.uk/install.html week 1 sitemap http://www.actionair.co.uk/a60damp.html week 1 sitemap http://www.actionair.co.uk/ascdamp.html week 1 sitemap http://www.actionair.co.uk/hydro.html week 1 sitemap http://www.actionair.co.uk/FishingWriteUp.pdf week 1 sitemap http://www.actionair.co.uk/pdf/Hospitals.pdf week 1 sitemap http://www.actionair.co.uk/maillistinfo.html week 1 sitemap http://www.actionair.co.uk/sitemap.html week 1 sitemap http://www.actionair.co.uk/products.html week 1 sitemap http://www.actionair.co.uk/copyright.html week 1 sitemap http://www.actionair.co.uk/minsys.html week 1 sitemap http://www.actionair.co.uk/legal.html week 1 sitemap http://www.actionair.co.uk/pdf/aeropac.pdf week 1 sitemap http://www.actionair.co.uk/aeropac.html week 1 sitemap http://www.actionair.co.uk/www.buildingdesign-news.co.uk week 1 sitemap http://www.actionair.co.uk/pdf/AirDistGenSpecAug04.pdf week 1 sitemap http://www.actionair.co.uk/pdf/ruskinbrochurweb.pdf week 1 sitemap http://www.actionair.co.uk/map.html week 1 sitemap http://www.actionair.co.uk/pdf/A-60_Marine%20March%20.pdf week 1 sitemap http://www.actionair.co.uk/pdf/a60newsrelease.pdf week 1 sitemap http://www.actionair.co.uk/pdf/pressreleasees.pdf week 1 sitemap http://www.actionair.co.uk/pdf/Introduction%20for%20Actionair%20Installations%20Manual.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9567.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9567.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/9567.dwg week 1 sitemap http://www.actionair.co.uk/drawings/1351%20c.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1351%20c.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/1351c.dwg week 1 sitemap http://www.actionair.co.uk/drawings/9772%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9772%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/1391b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1391b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9811.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9811.dwf week 1 sitemap http://www.actionair.co.uk/drawings/0244%20g.pdf week 1 sitemap http://www.actionair.co.uk/drawings/0244%20g.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/0244g.dwg week 1 sitemap http://www.actionair.co.uk/pdf/9430.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9812.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9812.dwf week 1 sitemap http://www.actionair.co.uk/drawings/2053%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/2053%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9564.dwf week 1 sitemap http://www.actionair.co.uk/drawings/4619d.pdf week 1 sitemap http://www.actionair.co.uk/drawings/4619d.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9804.dwf week 1 sitemap http://www.actionair.co.uk/drawings/6021%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6021%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6021b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/9889.dwf week 1 sitemap http://www.actionair.co.uk/drawings/6337%20c.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6337%20c.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6337c.dwg week 1 sitemap http://www.actionair.co.uk/drawings/9890.dwf week 1 sitemap http://www.actionair.co.uk/drawings/7168.pdf week 1 sitemap http://www.actionair.co.uk/drawings/7168.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9891.dwf week 1 sitemap http://www.actionair.co.uk/drawings/7169.pdf week 1 sitemap http://www.actionair.co.uk/drawings/7169.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9892.dwf week 1 sitemap http://www.actionair.co.uk/drawings/7510%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/7510%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9862-1.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9862.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9430.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9430.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/9430.dwg week 1 sitemap http://www.actionair.co.uk/drawings/9862-2.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9862-2.dwf week 1 sitemap http://www.actionair.co.uk/drawings/2821%20d.pdf week 1 sitemap http://www.actionair.co.uk/drawings/2821%20d.dwf week 1 sitemap http://www.actionair.co.uk/drawings/4170%20c.pdf week 1 sitemap http://www.actionair.co.uk/drawings/4170%20C.dwf week 1 sitemap http://www.actionair.co.uk/drawings/2594%20e.pdf week 1 sitemap http://www.actionair.co.uk/drawings/2594%20e.dwf week 1 sitemap http://www.actionair.co.uk/drawings/4171%20d.pdf week 1 sitemap http://www.actionair.co.uk/drawings/4171%20d.dwf week 1 sitemap http://www.actionair.co.uk/drawings/1519%20f.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1519%20f.dwf week 1 sitemap http://www.actionair.co.uk/drawings/6492%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6492%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/1497%20h.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1497%20h.dwf week 1 sitemap http://www.actionair.co.uk/drawings/7941%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/7941%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9026%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9026%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9673.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9673.dwf week 1 sitemap http://www.actionair.co.uk/drawings/1490%20i.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1490%20i.dwf week 1 sitemap http://www.actionair.co.uk/drawings/6487%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6487%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/1498%20h.pdf week 1 sitemap http://www.actionair.co.uk/drawings/1498%20h.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9674.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9674.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9479%20a.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9479%20a.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9707.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9707.dwf week 1 sitemap http://www.actionair.co.uk/drawings/4079%20d.pdf week 1 sitemap http://www.actionair.co.uk/drawings/4079%20D.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9683.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9683.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9675.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9675.dwf week 1 sitemap http://www.actionair.co.uk/drawings/9682.pdf week 1 sitemap http://www.actionair.co.uk/drawings/9682.dwf week 1 sitemap http://www.actionair.co.uk/drawings/fs65029.pdf week 1 sitemap http://www.actionair.co.uk/drawings/fs65029.dwf week 1 sitemap http://www.actionair.co.uk/drawings/hsp501a2.pdf week 1 sitemap http://www.actionair.co.uk/drawings/hsp501a2.dwf week 1 sitemap http://www.actionair.co.uk/drawings/ptc501a5.pdf week 1 sitemap http://www.actionair.co.uk/drawings/ptc501a5ptc.DWF week 1 sitemap http://www.actionair.co.uk/drawings/6470%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6470%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6470%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/6473%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6473%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6473%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/6471%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6471%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6471%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/6474%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6474%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6474%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/6472%20b.pdf week 1 sitemap http://www.actionair.co.uk/drawings/6472%20b.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/6472%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8001bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8001bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8001%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8012bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8012bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8012%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8002bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8002bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8002%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8013bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8013bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8013%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8003bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8003bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8003%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8014bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8014bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8014%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8004bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8004bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8004%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8015bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8015bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8015%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8005bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8005bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8005%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8016bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8016bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8016%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8006bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8006bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8006%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8017bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8017bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8017%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8007bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8007bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8007%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8008bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8008bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8008%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8019bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8019bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8019%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8009bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8009bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8009%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8020bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8020bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8020%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/8010bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8010bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8010%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/SF0291.pdf week 1 sitemap http://www.actionair.co.uk/drawings/SF0291.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/SF029.dwg week 1 sitemap http://www.actionair.co.uk/pdf/8009-B-WEB.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8011bsriabweb.pdf week 1 sitemap http://www.actionair.co.uk/drawings/8011bsriabweb.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/8011%20b.dwg week 1 sitemap http://www.actionair.co.uk/drawings/SF0301.pdf week 1 sitemap http://www.actionair.co.uk/drawings/SF0301.dwf week 1 sitemap http://www.actionair.co.uk/drawings/dwg/SF030.dwg week 1 sitemap http://www.actionair.co.uk/idrops/fancoilidrop.htm week 1 sitemap http://www.actionair.co.uk/spares/REC%20SPARES%20LETTER%20WEB%207%206%2007.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20AIR%20SHIELD%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20EMB%20PANELS%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20EMS%20PANELS%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20FIRE%20SHIELD%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20SMOKE%20SHIELD%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20TRS%20ACS%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20TRS%20M1%20&amp;%202%2021%208%2006.doc week 1 sitemap http://www.actionair.co.uk/downloads/A60%20FLA%20hole%20and%20DHP.xlt week 1 sitemap http://www.actionair.co.uk/spares/RECOMMENDED%20SPARES%20LIST%20A60%2011%2012%2006.doc week 1 sitemap http://www.actionair.co.uk/pdf/fshield.pdf week 1 sitemap http://www.actionair.co.uk/%5c week 1 sitemap http://www.actionair.co.uk/catalogues.html week 1 sitemap http://www.actionair.co.uk/pdf/controlmodes.pdf week 1 sitemap http://www.actionair.co.uk/pdf/Hydropac ECdata.PDF week 1 sitemap http://www.actionair.co.uk/pdf/Hydropac ECEHW230PDS.PDF week 1 sitemap http://www.actionair.co.uk/PDF/Air%20Diff%20-%20Model%20PF-HDA%20(AD)_2.pdf week 1 sitemap http://www.actionair.co.uk/PDF/SYSTEMPA1.pdf week 1 sitemap http://www.actionair.co.uk/pdf/pressurereliefflaps.pdf week 1 sitemap http://www.actionair.co.uk/pdf/storm.pdf week 1 sitemap http://www.actionair.co.uk/pdf/ES%20September-web_1.pdf week 1 sitemap http://www.actionair.co.uk/PDF/eml.pdf week 1 sitemap http://www.actionair.co.uk/pdf/Actionpac%2060%20and%201201.pdf week 1 sitemap http://www.actionair.co.uk/pdf/actionpacemsembaugust04.pdf week 1 sitemap http://www.actionair.co.uk/pdf/AirShield.pdf week 1 sitemap http://www.actionair.co.uk/PDF/dglw.pdf week 1 sitemap http://www.actionair.co.uk/pdf/05425m5-3p.pdf week 1 sitemap http://www.actionair.co.uk/pdf/HDI_Feb02.pdf week 1 sitemap http://www.actionair.co.uk/pdf/DWFXTM%20Install%20Guide%20Iss%202-web.pdf week 1 sitemap http://www.actionair.co.uk/pdf/dwf.pdf week 1 sitemap http://www.actionair.co.uk/pdf/EnergyShield.pdf week 1 sitemap http://www.actionair.co.uk/pdf/Access%20Shield%20Catalogue.pdf week 1 sitemap http://www.actionair.co.uk/mylink;%0d%0aelse%0d%0ahref=mylink.href;%0d%0awindow.open(href, week 1 sitemap http://www.actionair.co.uk/mb.html week 1 sitemap http://www.actionair.co.uk/mm.html week 1 sitemap http://www.actionair.co.uk/duct.html week 1 sitemap http://www.actionair.co.uk/tc.html week 1 sitemap http://www.actionair.co.uk/int32.htm week 1 sitemap http://www.actionair.co.uk/int33.htm week 1 sitemap http://www.actionair.co.uk/installguides.html week 1 sitemap http://www.actionair.co.uk/data.html week 2 sitemap http://www.actionair.co.uk/maintenance.html week 2 sitemap http://www.actionair.co.uk/marineapps1.htm week 2 sitemap http://www.actionair.co.uk/ssdamp.html week 2 sitemap http://www.actionair.co.uk/fbcurtdamp.html week 2 sitemap http://www.actionair.co.uk/transdamp.html week 2 sitemap http://www.actionair.co.uk/asdamp.html week 2 sitemap http://www.actionair.co.uk/industrial-tunnel-dampers.html week 2 sitemap http://www.actionair.co.uk/actpacem.html week 2 sitemap http://www.actionair.co.uk/actpaclns.html week 2 sitemap http://www.actionair.co.uk/spares/REC%20SPARES%20LETTER%20WEB%2021%208%2006.doc week 2 sitemap");sQ1[23]=new Array("http://www.actionair.co.uk/links.html","Actionair Link Partners","","If you are interested in linking to our website then please email the Website Administrator  Email enquiries@brecertification.co.uk. Web www.redbooklive.com  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[24]=new Array("http://www.actionair.co.uk/newspage.htm","Actionair News","","News Release - NEW ACTIONAIR MARINE FIRE DAMPER DESTINED FOR WORLD WIDE APPLICATION The best can get better still! Ruskin Air Management has launched a new, improved version of the world-beating Actionair A-60 Marine Fire Damper. Purpose designed for application in marine and offshore projects, Actionair A-60 Marine Fire Dampers provide a complete solution for fire safety requirements in association with ventilation and A/C systems. Units are now available in an extended range of sizes from 100mm X 100mm up to 1m square, with the option of multiple units to meet the needs of even larger applications Major success Ruskin has already achieved major success with the Actionair A-60 Marine design - particularly with builders of fast ferries and luxury yachts. Orders have been won from both European yards, including those in Italy and Germany and as far afield as Australia and Chile. Fire at sea can present an even greater hazard than on land. Safety equipment designed for marine application has to meet a whole list of stringent specifications. Actionair's A-60 Marine Fire Damper was the world's first to achieve the coveted USCG-EU MRA Certification, confirming its suitability for use in ships and other types of marine application all over the globe. Every unit also bears a stainless steel plate showing the distinctive &#8220;ship's wheel&#8221; logo that symbolises Marine Equipment Directive compliant (MED) approval and an individual number so that it can be tracked throughout its life cycle. Other key approvals include Lloyds EC Type Approval (Module B), Germanischer Lloyd Approval, Lloyds Certificate of Fire Approval and American Bureau of Shipping Certification (www.actionair.co.uk) Performance enhancing In its latest form the Actionair A-60 incorporates a number of performance enhancing features. These include an electric actuator option with a 60 second reset time, an LED indicator on the Electrical Thermal Release (ETR) and a more versatile Pneumatic Thermal Release (PTR) design. A-60 Marine Fire Dampers incorporate aerodynamic, stainless steel interlocking opposed blades, operated by a &#8220;failsafe&#8221; spring mechanism. &#8220;Failsafe&#8221; is achieved by means of a unique and patented Electrical Thermal Release (ETR), which operates automatically at 72&deg;C, or if the power supply is interrupted. A manual test switch permits periodic operation of the damper for test purposes, simulating actual &#8220;failsafe&#8221; release under fire conditions. Dampers can now be reset in just 60 seconds after a test. A green LED lamp is now built into the ETR housing - giving clear and simple visual confirmation that the actuator is receiving power, the ETR is correctly fitted and the thermal fuse is intact. The A-60's Pneumatic Thermal Release (PTR) assembly is supplied complete to 500mm of nylon tubing to connect the quick-fit PTR couplings and actuator. Activation of the in-built 74&deg;C fusible link causes air to exhaust from the actuator causing the spring loaded PTR to close the damper. Reset after testing can be achieved in as little as 3 seconds. Rectangular and circular ductwork A-60 Marine Fire Dampers are available for use with both rectangular and circular ductwork. They can be used in systems with maximum pressures up to 1500Pa and duct velocities to 15m/s. Models are suitable for both vertical and horizontal applications with airflow in either direction. The stainless steel aerodynamic blades are mounted in a standard 1.2mm galvanised steel flanged type casing with a single penetration for the drive control. An optional 316 all stainless steel casing is also available. This complies with Class A and B of Eurovent 2/2 and HVCA Ductwork specification DW144. While strong and reliable, the A-60 Marine casing is light in weight to permit easier installation. Blades - which are available in either 430 grade or 316 stainless steel options - are normally open, with &quot;fail-safe&quot; to the closed position. IP54 rated Control Modes are available for 24 volt, 120 volt or 230 volt electrical supply. Control Modes are designed for location outside the ductwork for easy access during installation and maintenance and are direct coupled to the Damper using a unique positive connection system. Download This Press Release Download The A60 Marine Catalogue News Release - NEW ES DAMPER RANGE ENHANCES ACTIONAIR&#8217;S HEAVY DUTY AIR CONTROL AND SHUT-OFF CAPABILITY Actionair has launched an enhanced range of Heavy Duty Air Control and Shut-off Dampers. The introduction of this new ES range follows an intensive period of development involving both Actionair's Whitstable headquarters and parent company Ruskin&#8217;s research and development laboratory in Kansas City. As a result Actionair will be able to offer a truly comprehensive service embracing standard solutions and specials such as the Ruskin &quot;Bubble&quot; Damper for those infrequent, but vital applications where ultra low-leakage is of paramount importance. The new ES range embraces dampers for systems requiring air control and low closed-blade leakage characteristics. Four models are available to cover most typical applications - all in rectangular, circular, or flat oval configurations (with matching spigotted casings) and a range of sizes from 200mm to 2080mm (double section). Specifiers may opt for either standard opposed blade movement, or the optional parallel blade design. All models feature blades retained within the width of the casing so they cannot foul adjacent grilles, louvres etc. The new Actionair ES 35 and 36 dampers are designed for horizontal mounting in air conditioning and ventilation ductwork. They feature blades with a triple V configuration, fabricated from galvanised steel. Actionair ES 36 model combines all the performance capability of the basic air control design with the additional feature of a &#8220;shut off&#8221; function thanks to their low leakage performance when the blades are closed. This low closed blade leakage is achieved by means of stainless steel side gaskets and special blade seals of a synthetic material. The closed blade leakage of ES 36 damper conforms to EN1751 Class 2. Type ES 35 and 36 dampers are suitable for system pressures up to 1500Pa and duct velocities up to 10m/s. Ultra quiet For applications where both air control and shut-off functions must be combined with ultra quiet operation, Actionair offers the new ES50 design. This high performance damper features aluminium blades with a special aerodynamic profile, purpose-designed for low noise generation. Mounting the blade drive mechanisms out of the airstream serves to further minimise pressure and noise. Blade tip seals also ensure very low air leakage in the closed position - Actionair ES50 Dampers perform to EN1751 Class 3. Rectangular ES dampers can be supplied housed in a deep galvanised steel frame with 40mm flanges and pre-punched corner holes to match proprietary duct flange systems. As an alternative spigotted casings are available for rectangular models and all circular and flat oval versions. The Actionair ES range is supported by a full range of matching components including a choice of control options. Extended spindles for motorised control are supplied as standard. Alternatively, users may choose manual quadrant control. Quadrants are supplied from the Actionair factory as separate items for on site fitting. Finally, customers may opt for factory fitted Belimo Actuators with a choice of 24V or 230V open/closed, or spring return operation. A 24V modulating version is also available. Perfect complement The new ES Dampers form a key component in the industry's most comprehensive range of fire and smoke control products. They offer a perfect complement to the Actionair Air/Shield range of Air Control and Shut-off Dampers. Actionair&#8217;s parent company Ruskin is a world leader in damper design and manufacture and the full spectrum of Ruskin products is available to underwrite Actionair's range of solutions. The extensive Ruskin ranges include heavy-duty designs, specifically developed to meet international demand for industrial, marine and tunnel ventilation damper systems that can operate in the most arduous conditions. Download This Press Release Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[25]=new Array("http://www.actionair.co.uk/drawing.html","Actionair Technical Drawing Archive","","Home Products Actionair Drawings Actionair Technical Drawing Archive Introduction for Actionair Installations - Click here to view in PDF Drawing formats - There are three formats in which our drawings can be downloaded or viewed PDF, DWF and DWG. Typically the newer DWF format is faster to download with smaller file sizes. All you need is the DWF viewer which can be installed from the link below.The dwf viewer enables users to view and print complex 2D and 3D drawings. Autodesk® DWF viewer Once installed, the viewer can open all versions of DWF&#8482; within your web browser, or via a standalone program. Access to the viewers' tools can be gained by clicking the right mouse button and selecting from a pop-up menu, or via buttons on a toolbar. DOWNLOAD NOW Download a free copy of Autodesk DWF Viewer now. Click on the link below to complete a short form or go straight to download to get your free copy. Adobe® Acrobat Viewer Once installed, the viewer can open all versions of PDF within your web browser, or via a standalone program. Tired of waiting for the file to download and then having to get the software to view it, click this button or the drawing thumbnail to view your drawings instantly! Product Technical Drawing Index Please click the relevant section: Section 1 - Damper fixing options Section 2 - Controls and Accessories Section 3 - Component Materials Drawings Section 4 - Damper Multiple Assembly Drawings Section 5 - Approved Installations Nb* for best viewing results acrobat reader 5 or above is recommended. To save a drawing right click and save as. Disclaimer &quot;The information contained herein is subject to change without notice due to continuing research and development. Ruskin Air Management limited, provide 'as is' and no warranty, express or implied, is made with respect to this website or any content on this website.&quot; All Rights Reserved. &quot;We are constantly trying to improve our service and the drawings section, and would like your feedback on how we can improve it, and offer more, so if there is anything you want to suggest please click this link, all feedback, positive or criticism is greatly received”.  Drawings  Section 1 - Damper fixing options  AA/F/1349-E AA/F/1350-C AA/F/9462-D Replaced with drawing AA/F/9811' 'Replaced with drawing AA/F/7168 &amp; AA/F/7169' 'Replaced with drawing AA/F/9812'  AA/F/9567 Fire/Smoke damper under concrete slab 272kb 41kb 210kb  AA/F/1351-C Fire/smoke damper with cleats &quot;Access side&quot; 208kb 43kb 94kb AA/F/9772 Fire/Smoke damper on top of concrete slab 132kb 52kb  AA/F/1391-B Fire/Smoke Damper Cleats - Horizontal (2 Pairs) mounted in slab 77kb 25kb  AA/F/9811 General Arrangement for 1.2mm gauge angle flange, NON-ACCESS SIDE 84kb 41kb AA/F/0244-G DWFX-C General arrangement for welded angle cleat (Vertical damper top cleats) 247kb 49kb 98kb AA/F/9812 General Arrangement for 1.2mm gauge angle flange, ACCESS SIDE 80kb 39kb  AA/F/2053-A General arrangement of Installation Frame Detail 324kb 21kb AA/F/9564-B Angle Flange and Cleat Arrangement 128kb AA/F/4619-D Fire/smoke damper with cleats &quot;Non Access side&quot; 216kb 53kb  AA/F/9804 Smoke Shield PTC With Installation Frame 275kb AA/F/6021-B General arrangement for Smoke/Shield PTC with a smoke curtain fixing flange 211kb 45kb 103kb AA/F/9889 1.2mm Angle Flanges (DAMPER SIDES) - NON-ACCESS SIDE 82kb  AA/F/9890 1.2mm Angle Flanges (TOP AND BOTTOM) - NON-ACCESS SIDE 81kb  AA/F/7168-B General arrangement for 3mm gauge angle flange, NON ACCESS SIDE 85kb 42kb AA/F/9891 1.2mm Angle Flanges (DAMPER SIDES) - ACCESS SIDE 83kb  AA/F/7169-A General arrangement for 3mm gauge angle flange, ACCESS SIDE 80kb 39kb AA/F/9892 1.2mm Angle Flanges (TOP AND BOTTOM) - ACCESS SIDE 80kb  AA/F/7510-A Fire/Shield with installation frame in concrete slab 503kb 140kb AA/F/9862 A60 MARINE - WITH ELECTRICAL AND PNEUMATIC 431kb 155kb Sheet 1 of 2 AA/F/9862 A60 MARINE - WITH ELECTRICAL AND PNEUMATIC 461kb 227kb 3D Sheet 2 of 2 Back to top index Section 2 - Controls and Accessories  AA/F/2821-D FDRSI (Fire Damper Released, Status Indicator) 24 Volt ( Mode 5) Facia & Wiring 345kb 29kb AA/F/4170-C  DSI 230 Volt Facia (Mode 6) 121kb 40kb AA/F/2594-E FDRSI (Fire Damper Released, Status Indicator) 120 Volt & 230 Volt (Mode 120 & Mode 6) Facia & Wiring 354kb 29kb AA/F/4171-D  DSI 230 Volt Wiring (Mode 6) 198kb 37kb AA/F/1519-F DTU 24Volt Facia (Mode 5) (Damper Test Unit) 126kb 42kb AA/F/6492-B  DCU 24 Volt Facia (Mode 5) (Damper Control Unit) 143kb 37kb AA/F/1497-H DTU 24Volt Wiring (Mode 5) 212kb 59kb AA/F/7941-B  DCU 24 Volt Wiring (Mode 5) 211kb 37kb AA/F/9026-A DTU 120 Volt Facia (Mode 120) 140kb 39kb AA/F/9673  DCU 120 Volt Facia (Mode 120) 125kb 37kb AA/F/1490-I DTU 230Volt Facia (Mode 6) 129kb 41kb AA/F/6487-A  DCU 230 Volt Facia (Mode 6) 137kb 37kb AA/F/1498-H DTU 120Volt &amp; 240 Volt Wiring (Mode 120 &amp; Mode 6) 203kb 39kb AA/F/9674  DCU 120 Volt &amp; 230 Volt Wiring (Mode 120 &amp; Mode 6) 214kb 37kb AA/F/9479-A DSI 24 Volt Facia (Mode 5) (Damper Status Indicator) 126kb 37kb AA/F/9707  DCU M5-2P &amp; M6-2P facia 187kb 46kb AA/F/4079-D DSI 24 Volt Wiring (Mode 5) 194kb 38kb AA/F/9683  DCU M5-2P Wiring (24 Volt) Wiring 153kb 33kb AA/F/9675 DSI 120 Volt Facia (Mode 120) 126kb 37kb AA/F/9682  DCU M6-2P Wiring (230 Volt) Wiring 154kb 32kb Back to top index Section 3 - Component Materials Drawings       FS6502-10  Fire/Shield component materials 588kb 139kb HSP501A-2  Hot/Shield PTC component materials 463kb 107kb PTC501A-5  Smoke/Vent/Shield PTC component materials 113kb 176kb   Back to top index Section 4 - Damper Multiple Assembly Drawings       AA/F/6470-B  Smoke/Shield PTC 2 wide x 1 high multiple arrangement 296kb 20kb 92kb AA/F/6473-C  Smoke/Shield PTC 2 wide x 2 high multiple arrangement 366kb 22kb  AA/F/6471-B  Smoke/Shield PTC 2 high x 1 wide multiple arrangement 289kb 20kb 92kb AA/F/6474-B  Smoke/Shield PTC 3 high x 2 wide multiple arrangement 406kb 25kb 120kb AA/F/6472-B  Smoke/Shield PTC 3 high x 1 wide multiple arrangement 331kb 20kb 98kb Back to top index Section 5 - Approved Installations       AA/F/8001-B  Fire / Smoke damper into brick / block wall 769kb 36kb 131kb AA/F/8012-B  Fire / Smoke damper into concrete wall, joining slab ceiling, steel angle fixings. 880kb 27kb 203kb  AA/F/8002-B  Fire / Smoke damper into Cavity brick / block wall, with cavity sleeve protection. 833kb 36kb 227kb AA/F/8013-B  Fire / Smoke damper into concrete wall, joining slab ceiling, angle fixing. 809kb 30kb 271kb AA/F/8003-B  Fire / Smoke dampers into both skins of cavity brick / block wall 865kb 40kb 191kb AA/F/8014-B  Fire / Smoke damper into fire curtain, in duct. 692kb 19kb 113kb AA/F/8004-B  Fire / Smoke damper into brick / block wall, joining slab ceiling. 788kb 31kb 125kb AA/F/8015-B Fire / Smoke damper into fire curtain, mesh protection. 591kb 19kb 108kb AA/F/8005-B  Fire / Smoke damper into brick / block wall, joining slab ceiling, angle fixing. 841kb 30.2kb 148kb  AA/F/8016-B  Fire / Smoke damper inside duct, remote from wall. 858kb 22kb 122kb AA/F/8006-B  Fire / Smoke damper into brick / block wall, joining slab ceiling, top angle fixing. 813kb 29kb 125kb AA/F/8017-B  Fire / Smoke damper into concrete slab floor. 765kb 26kb 134kb AA/F/8007-B  Fire / Smoke damper into brick / block wall, joining slab ceiling, steel angle fixings. 864kb 25kb 142kb  AA/F/8008-B  Fire / Smoke damper 'Z' angle fixed onto brick / block wall. 701kb 163kb 128kb AA/F/8019-B  Fire / Smoke damper into concrete slab floor, with shuttering. 755kb 24kb 169kb  AA/F/8009-B  Fire / Smoke damper into concrete wall 800kb 30kb 119kb AA/F/8020-B  Fire / Smoke damper 'Z' angle fixed onto concrete slab floor. 626kb 22kb 176kb  AA/F/8010-B  Fire / Smoke damper into concrete wall, angle fixing. 810kb 30kb 281kb SF029 REV 1  PTC DWFX-F Intallation System 292kb 22kb 115kb  AA/F/8011-B  Fire / Smoke damper into concrete wall, eye bolt fixing. 808kb 37kb 336kb SF030 REV 1  FS DWFX-F Intallation System 222kb 22kb 227kb Back to top index Autodesk i-Drop Library for Fancoil Units Autodesk i-drop® technology gives you the ability to drag-n-drop content from the web straight into your drawing session. It also gives designers and developers the power to create web pages that can easily be dragged-and-dropped into i-drop aware Autodesk design products. Click to see Actionair Fancoil i-drop library and drop drawings into your Autodesk application with &#8220;Download idrop indicator&#8221; To learn more about i-drop technology click here.  Recommended Spares Lists All recommended spares documents are available in Microsoft Word format allowing you to add your details. To save the file to your computer, right click on the relevant link and then click 'Save Target As': RECOMMENDED SPARES LETTER AIR SHIELD RECOMMENDED SPARES LIST EMB PANELS RECOMMENDED SPARES LIST EMS PANELS RECOMMENDED SPARES LIST FIRE SHIELD RECOMMENDED SPARES LIST SMOKE SHIELD RECOMMENDED SPARES LIST TRS ACS RECOMMENDED SPARES LIST TRS M1 &amp; 2 RECOMMENDED SPARES LIST  SWIMMING POOL APPLICATIONS Please Note: - Actionair dampers are not suitable for Swimming Pools or associated areas treated with either chlorine or ozone. Dampers will only be supplied upon written instructions and with the knowledge that any guarantee will be invalid. Should Dampers be supplied under these conditions for Swimming Pools or associated areas, a regular maintenance programme should be implemented. This should consist of a visual inspection of damper blades and casings, cleaning and spraying of a light machine oil to the exposed areas that will come into contact with the contaminated air. The above maintenance programme is no guarantee that the damper life expectancy will be extended. Whilst we cannot guarantee the performance of our standard damper manufacture, 316 grade Austenitic stainless steel will provide the highest protection. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved Minimum system requirements | Lega l");sQ1[26]=new Array("http://www.actionair.co.uk/prices.html","Actionair Price Lists","","Home Products Prices  Actionair Product Price Sheets The price sheets available are of the Actionair core products in single module size and to the build specification shown in the product literature available on this website. For multiple assemblies, alternative material specifications or for products not listed please contact the sales office at Whitstable. sales@actionair.co.uk.  To access these pricing sheets please enter your e mail address. This will allow us to automatically update you as and when these prices change. As part of our continuing effort to keep our customers updated subscribers to the Actionair mailing list will receive frequent updates on new catalogues, drawings, technical information and company related news. If you have been subscribed by mistake or wish to unsubscribe then please email the Site Administrator to be removed. Company: Contact Name Email Address:   The material on these price sheets is directed solely at those who are familiar with the company&#8217;s products and pricing policy. Ruskin Air Management Limited has taken every care in the preparation of the content of these pages. Ruskin Air Management Limited disclaims all warranties, express or implied, as to the accuracy of the information contained in any of the price sheets. Ruskin Air Management Limited shall not be liable to any person for any loss or damage which may arise from the use of any of the information contained in any of the materials on this website. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[27]=new Array("http://www.actionair.co.uk/spares.html","Actionair Product Recommended Spares","","Home Products Recommended Spares Recommended Spares Lists Life Cycle Costings. The attached sheets indicate our recommended lists of parts that should be held in stock to cover a 2 year operating period (shown as a percentage of total numbers of dampers, actuators or products supplied). We currently estimate the Life Expectancy of the Product to be in excess of 15 Years and would therefore, generally have parts available to either service the relevant product, or would offer an alternative, or offer a repair service. You can either use the 2 year formula suggested in paragraph one above and multiply this out for the number of years required, or review spares stock on a two yearly basis. Note: Parts quoted specific to product types, not actual orders. In addition to these requirements we would also recommend a routine cleaning and testing of damper closure/operation. All recommended spares documents are available in Microsoft Word format allowing you to add your details. To save the file to your computer, right click on the relevant link and then click 'Save Target As': RECOMMENDED SPARES LETTER AIR SHIELD RECOMMENDED SPARES LIST EMB PANELS RECOMMENDED SPARES LIST EMS PANELS RECOMMENDED SPARES LIST FIRE SHIELD RECOMMENDED SPARES LIST SMOKE SHIELD RECOMMENDED SPARES LIST TRS ACS RECOMMENDED SPARES LIST TRS M1 &amp; 2 RECOMMENDED SPARES LIST RECOMMENDED SPARES LIST A60 11 12 06.doc   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[28]=new Array("http://www.actionair.co.uk/applications.html","Actionair Product Special Applications","","Home Products Special Applications SWIMMING POOL APPLICATIONS Please Note: - Actionair dampers are not suitable for Swimming Pools or associated areas treated with either chlorine or ozone. Dampers will only be supplied upon written instructions and with the knowledge that any guarantee will be invalid. Should Dampers be supplied under these conditions for Swimming Pools or associated areas, a regular maintenance programme should be implemented. This should consist of a visual inspection of damper blades and casings, cleaning and spraying of a light machine oil to the exposed areas that will come into contact with the contaminated air. The above maintenance programme is no guarantee that the damper life expectancy will be extended. Whilst we cannot guarantee the performance of our standard damper manufacture, 316 grade Austenitic stainless steel will provide the highest protection.  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[29]=new Array("http://www.actionair.co.uk/fsdamp.html","Actionair fire shield fire dampers","The Fire/Shield range of quality engineered fire dampers are suitable for air conditioning and ventilation systems requiring up to 4 hour fire protection.","Home Products Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Series Easier Reset Mechanism Choice of 230 Volt A.C. or 24 Volt A.C. and D.C. remote electro magnet fail-safe releases on cassette type options only. Tested and approved to BS ISO 10294-1: 1996, BS EN 1366-2: 1999 and BS 476 Part 20: 1987 Fire Test Standards.   Actionair Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Series The Fire/Shield range of quality engineered dampers are suitable for air conditioning and ventilation systems requiring up to 4 hour fire protection. These stainless steel bladed Actionair Fire/Shield Dampers fail-safe closed and are supplied with the new innovative, even easier Single-Handed Reset Self Latching Removable Release Mechanism Cassette, which permits single handed reset. Application Fire/Shield Dampers are designed for application in normal dry filtered air systems. If exposed to fresh air intakes and/or inclement conditions the damper should be subject to a planned inspection programme. Any specialists and/or aggressive applications (e.g. swimming pools) may invalidate our warranty, please refer to Actionair Sales Office.  Construction Catalogue The Type 1.4016 (430) Ferritic Stainless Steel folding blade curtain, providing maximum strength, form an impenetrable fire shield. Housed within a galvanised steel outer casing with fully welded spigots and corners to comply with DW144 class A, B &amp; C. Optional blade construction Type 1.4401 (316) Austenitic Stainless Steel.  (View Catalogue) All Catalogues  Product Conformity Awarded by the Loss Prevention Certification Board Limited (LPCB).  New Cassette Specification Patented design. Made of Polyphenylenesulphide (PPS) resin reinforced with 40% glass fibre (GF-PPS). Technically advanced engineering polymer. PPS is stable at temperatures up to 200 &deg;C. Cassette construction is of very high strength and has excellent creep and fatigue resistance. Low smoke and toxic emissions in fire conditions. Halogen free PPSPPS has a very low moisture absorption. PPS is corrosion resistant. The Cassette construction is environmentally friendly (recyclable material). The new Cassette is retrofit table to existing Fire/Shield Dampers (by use of a simple optional adaption bracket). One Cassette to suit all damper material options.  Activation The cassette mechanism is completely removable from the Fire/Shield Damper by manually releasing the retaining clip. This allows replacement of the cassette without the use of tools. Simple hand operation enables the damper curtain to be reset and latched in the fully Open Position. This increases the ease and speed with which the Fire/Shield Damper can be reset following periodic functional testing in accordance with British Standard BS 5588: Part 9 Code of Practice for Ventilation and Air Conditioning Ductwork. The thermal actuator in the form of a helical memory metal compression spring is produced from a special Cu- Zn-AI brass alloy. On temperature rise this expands and at 72&deg;C, causes the Fire/Shield damper blades to release.On cooling, the spring reverts to the close-coiled state offering the significant advantage of repeated operation, unless it has reached temperatures in excess 170 &deg;C, where it will remain extended, preventing reset. The cassette body will start to lose its structural strength at temperatures in excess 200 &deg;C and will stop supporting the blades. For more information including dimensional data please view the Fire / Shield Catalogue Here. Specification for Curtain Fire Dampers Fire dampers shall be manufactured with stainless steel folding curtain housed within a galvanised steel outer casing with continuously welded corners and spigot connections comply with DW 144 class A B and C. The Fire Dampers to include a release cassette with memory metal spring, which will release the damper at 72 dec C, the cassette shall also be self-latching reset. Fitted with stainless steel side gaskets to minimise the spread of smoke and other products of combustion, and have an external visual indication of the damper curtain. Fire dampers shall be tested to and comply with BS EN 1366 - 2 or BS ISO 10294 - 1 to E classification. Dampers shall be approved by the LPCB certification scheme. Fire dampers to be complete with factory fitted installation frame suitable for masonry wall or dry wall installation. (as specified) Fire dampers to be type Fire/Shield as manufactured by Actionair. Please click here to copy the specification to your clipboard ready to paste into your project specification.   Innovative New Cassette Innovative cassette, new design with even easier single handed reset. Ordinary steel curtain fire dampers involve a complex pull and lift curtain opening operation, further complicated by having to hold the curtain in the fully open position against the constant tension of closure springs whilst attempting to reset or replace the fusible link unsighted. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved Minimum system requirements | Lega l ALL");sQ1[30]=new Array("http://www.actionair.co.uk/hsdamp.html","Actionair Hot Shield damper","Actionair have developed the Hot/Shield PTC™ High Temperature Smoke Management and Fire Dampers along with the Hot/Shield Vent PTC™ Smoke Control and Extract Dampers to enable the concepts of fire engineering to be employed in ducted smoke ventilation systems.","Home Products Hot/Shield High operating temperature smoke management and fire dampers Tested and approved to BS 476 Part 20 Advanced Thermal Enclosure   Actionair Hot/Shield High operating temperature smoke management and fire dampers Actionair have developed the Hot/Shield PTC&#8482; High Temperature Smoke Management and Fire Dampers along with the Hot/Shield Vent PTC&#8482; Smoke Control and Extract Dampers to enable the concepts of fire engineering to be employed in ducted smoke ventilation systems. These dampers designed, tested and approved to deliver high temperature operation at up to 300 &deg;C for one hour, provide the designer with the capability of extracting hot smoke and combustion gases through a common smoke extraction duct linked to adjacent fire zones and floors. Application As smoke can spread rapidly and efficiently through a building ductwork system, damper operation needs to be initiated by a smoke detection system, as thermal sensing can often be too late. Hot/Shield PTC&#8482; and Hot/Shield Vent PTC&#8482; dampers are designed to be interfaced with a smoke detection/fire alarm system.  Construction Hot/Shield PTC&#8482; Catalogue Hot/Shield Vent PTC&#8482; High Operating Temperature Smoke Control and Extract Dampers comprising of 75mm stainless steel aerodynamic blades incorporating synthetic seal, with stainless steel blade end bearings and peripheral gasketing. Housed in a galvanised fully welded, spigotted casing suitable for square, rectangular, circular or flat oval connections. The totally enclosed precise movement opposed blade drive shall be positioned out of the airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplock&#8482; drive interface mechanism, which is totally independent of the ductwork. Hot/Shield Vent PTC&#8482; dampers and the in appropriate insulated control modes shall be arranged for motor close and spring open operation.  (View Catalogue) All Catalogues  Actionair have developed a new technically advanced thermal enclosure in conjunction with the manufacturers of the base product to achieve and exceed a total immersion of damper and actuator assembly at elevated temperatures test specifications. This new enclosure is made from a phenolic composite resin with excellent endothermic properties. A chemical reaction occurs within the insulating material when it is heated. This reaction has the effect of lowering the temperature inside the enclosure, thus prolonging the duration of the actuator&#8217;s operation at elevated temperatures. New PTC Control Modes and Ancillaries Acrobat (PDF) Version PDF Download Size = 231kb These new series of control modes achieve 60 seconds to drive to the end position, with a 20 second spring return time. This brings Actionair dampers in line with imminent European standardisation for fire and smoke control.  Approvals  Hot/Shield PTC&#8482; dampers, when closed, are compliant to BS 476 Part 20 Fire Damper Test Standards.    Specification for HOT / SHIELD PTC Smoke management dampers shall be of double skin spigot case having continuously welded corners and spigot connections. Stainless steel aerofoil blades of double skin construction, interlocking within twin trailing edges, the interlocking providing a double metal seal. Incorporated within the blade profile is a silicone seal to ensure low closed blade leakage at temperatures up to 300&deg;C for 2 hour. Smoke management dampers to be complete with factory fitted installation frames (where specified) to HVC 06/05/83 specification. Smoke management dampers shall be fitted with a snaplock interface and relevant control mode (24 volts or 240 volt as specified on the drawings). Hot/Shield PTC&#8482; dampers, when closed, are compliant to BS 476 Part 20 Fire Damper Test Standards. Please click here to copy the specification to your clipboard ready to paste into your project specification.  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Products | Catalogues | Contact Copyright © 2005actionair. All Rights Reserved Minimum system requirements | Lega l ALL");sQ1[31]=new Array("http://www.actionair.co.uk/newredcatalogues/SmokeShield.pdf","Smoke/Shield  April 08 WEB.qxd","","April 2008 Smoke/Shield PTCTM Includes new Damper Release and Indication Module (DRIM). Smoke/Shield PTCTM Proportional Torque Control Automatic Smoke and Fire Dampers Features G Proportional Torque Control for optimised torque performance. G Unique snaplockTM drive interface ensures user friendly connection of Control Mode to Damper. G Tested and approved to BS ISO 10294-1:1996, BS EN 1366-2:1999 and BS476 pt. 20:1987 Fire Test Standards. G Smoke/Shield PTC is an LPCB approved product and conforms to the requirements of LPS1162 iss 2. G Easy connection to square, rectangular, circular and flat oval ductwork. G Unique and patented Electrical Thermal Release for ultimate safety. G Halogen Free Low Smoke and Fume cabling supplied as a standard safety feature. G Actionpac Damper Control System compatibility. G Vent/Shield PTCTM reverse action dampers for smoke release or exhaust applications. G Pneumatic Option. Dampers Controls Fancoils Ruskin Air Management Limited www.ruskinuk.co.uk Smoke/Shield PTCTM Introduction Actionair has always been at the forefront in the innovative development, design and manufacture of life safety dampers and associated controls. Now with the unique Smoke/Shield PTCTM range of Automatic Smoke and Fire Dampers Actionair continues this tradition. The Range The Smoke/Shield PTCTM range of Quality Engineered Dampers are suitable for air conditioning and ventilation systems requiring up to 4 hour smoke and fire protection. Refer to Installation and Maintenance Guide on our website for precise details. These aerodynamic stainless steel interlocking opposed blade dampers are fail-safe spring close with manual or electrical reset control modes. The Vent/Shield PTCTM Damper range are reverse acting for smoke release or exhaust. (Manual system not available). Proportional Torque Control The control mode and snaplockTM drive interface provides the optimum mechanical advantage to the damper by delivering: the right torque, in the right place, at the right time. Damper ­ Control Mode Interface snaplockTM Drive Interface Designed to develop Proportional Torque Control (Right Hand Damper shown) Control Mode Mode 5/6 shown Mode 9, Pneumatic Actuator Smoke/Shield PTCTM 501 Damper Damper Drive Shroud and Transit Plate 3 Position Location Plate Pneumatic Bracket Smoke/Shield PTCTM Damper with unique snaplockTM Damper/Control Mode Interface Automatic Smoke and Fire Damper and Control Mode assembly with a unique and dedicated Proportional Torque Control for optimised Damper/Control Mode torque performance. The unique snaplockTM drive interface ensures user friendly, easy and secure connection of the Control Mode to the Damper. The drive interface which is totally independent of the ductwork, eliminates the need for costly dedicated duct sections, and provides ease of connection to square, rectangular, circular and flat oval ductwork. This drive interface guarantees that only the correct and certified Actionair products can be used. 2 www.actionair.co.uk Smoke/Shield PTCTM Blade Features Smoke/Shield damper blades are aerodynamic double skin, type 1.4016 (430) Ferritic Stainless Steel, which are 75mm x 0.5mm thick and interlock to form a positive smoke and fire resisting shield. Incorporated within the blade profile is a synthetic seal to ensure low closed blade smoke leakage. Stainless Steel blade end bearing and peripheral gasketting maintain the low closed blade smoke leakage whilst allowing for expansion under full fire conditions. Optional Blade construction type 1.4401 (316) Austenitic Stainless Steel. 12.7 75 41.5 Smoke/Shield PTCTM blade dimensions Smoke/Shield PTCTM fail-safe closed Vent/Shield PTCTM fail-safe open Control Options A choice of four Control Modes are located outside of the ductwork for easy access and installation. The motorised Control Modes 5 and 6 can be fitted in 3 positions through 180° (see page 7) allowing maximum on-site installation flexibility. All Smoke/Shield Control Modes must be in the released position prior to connection. Control Mode 1 Manual reset ­ with volt free contact for provision of external indication of damper status. Not available on Vent/Shield. Mechanical Fusible Link Control Mode 1 (Smoke/Shield only) Fail-safe by means of a unique and patented mechanical fusible link which operates at approx. 72 °C, complying with BS5588 Part 9: 1999. The link assembly incorporates a safety feature that ensures the fail safe status of the damper if the link is not fitted on to the ductwork. A manual test may be performed by simple unscrewing the wing nut situated on the fusible link. Electrical Thermal Release (ETR) Control Modes 5 and 6 (Smoke/Shield only) Fail-safe by means of a unique and patented electrical thermal release which operates at 72 °C or if power supply is interrupted, complying with BS 5588 Part 9: 1999. The ETR incorporates triple safety features, including an ingenious device that ensures the fail-safe status of the damper if the ETR is not fitted on to the ductwork. A manual test switch allows periodic operation of the damper for testing purposes simulating actual fail-safe release under smoke/fire conditions. For safety reasons the ETR/PTR is designed to operate once only when the activation temperature is reached. FUSIBLE LINK Control Modes 5 and 6 Optimised motor/spring return control modes with remote reset-release facilities, with volt free contacts for provision of external indication, monitoring and control by means of an Actionpac damper control system, or by a suitable alternative proprietary control format. Control Mode 9 Pneumatic Pneumatic Thermal Release (PTR) Control Mode 9 (Smoke/Shield only) Fail-safe is by means of a Pneumatic Thermal Release (PTR) which operates at 74°C, or if air supply is interrupted. ETR Indication light As standard, a green LED lamp is built into the ETR housing. This gives the user a simple and clear visual check that the Actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. Note: Vent/Shield PTCTM Dampers and associated control modes are reverse action with spring opening (Mode 1 not available). www.actionair.co.uk 3 Smoke/Shield PTCTM Casing Features With double skin spigotted galvanised steel (to BS EN 10327) 1.2mm thick casing the Smoke/Shield PTCTM dampers comply to Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B and C of HVCA Ductwork Specification DW144. Damper casings are manufactured with fully welded spigotted connections suitable for Square, Rectangular, Circular and Flat Oval duct connections. As an extra cost option, casings can be manufactured in Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic Stainless Steel, 1.2mm thick. The Smoke/Shield PTCTM Damper blades are normally open and fail-safe to the closed position.This product is fire rated. The Vent/Shield PTCTM Damper blades are normally closed and fail-safe to the open position for smoke release or exhaust. Dampers may be installed both vertically and horizontally. In addition, for vertical installations, the damper may be installed with the blades running vertically. Airflow can be be from either direction. Actionair Smoke/Shield PTCTM and Vent/Shield PTCTM Dampers are designed for applications in normal dry filtered air systems. If exposed to fresh air intakes and/or inclement conditions, the dampers should be subject to a planned inspection programme. For specialist and/or aggressive applications, please refer to Actionair Sales Office. Multiple Assemblies Square and rectangular casings are available in multiple module arrangements supplied complete with joining channels for site fixing by others. STD RHD STD RHD Application Parameters Smoke/Shield PTCTM and Vent/Shield PTCTM Dampers to maximum width and height dimensions (see page 10 and 11) can be used where the operating total system pressure is up to 1500 Pascals and duct velocities to 15m/second. LHD STD RHD LHD STD RHD LHD STD RHD STD RHD LHD Type SPG Square / Rectangular Type SPG Circular Type SPG Flat Oval 4 www.actionair.co.uk Smoke/Shield PTCTM Application and Wiring Mode 1 PTC (Manual System) Manual opening. Spring instant closure via mechanical fusible link. (Smoke/Shield version only, Vent/Shield not available.) GREEN/ YELLOW BROWN BLUE BLACK Vent/Shield PTCTM Dampers and associated Control Modes M5 & M6 are reverse action with spring opening. COMMON NORMALLY CLOSED NORMALLY OPEN VOLT FREE CONTACT CLOSED WHEN DAMPER RESET (at 85° ) RATED 250V 5A DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Mode 5 PTC (24V System) The following applies for ETR version. (ETR not supplied on Vent/Shield.) Power On ­ Damper motors reset. Power Off ­ Spring release. Electrical Thermal Release. External mechanical position indicator with pointer. Release Time 20 secs. Reset Time 60 secs. (Connect 24V via a safety isolating transformer.) IP54 Rated. ­ 30...+50 °C CONTINUOUS BLACK 1 2 1 2 3 A.C./D.C.24V 50 / 60 Hz ­ + M WHITE SUPPLY 24V A.C. or D.C. TYPICALLY 10W (MOTORING) 2W (RESET) CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED 12.5 V A 10 / 2 W Imax 8.3A @ 5ms A.C. 250V 6(3)A 4 5 6 TF 72 °C ELECTRICAL THERMAL RELEASE (MUST BE FITTED TO DUCTING FOR DAMPER OPERATION). NON ETR VERSION AVAILABLE ON REQUEST (SPRING BIASED TEST SWITCH) CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Mode 6 PTC (230V System) The following applies for ETR version. (ETR not supplied on Vent/Shield.) Power On ­ Damper motors reset. Power Off ­ Spring release. Electrical Thermal Release. External mechanical position indicator with pointer. Release Time 20 secs. Reset Time 60 secs. (To isolate from main power supply, the system must incorporate a device which disconnects the phase conductors, with a least 3mm contact gap.) Note: 120V A.C. version also available. IP54 Rated. A.C. 230V 50 / 60 Hz M BLUE BROWN N L1 1 2 3 SUPPLY 230V A.C.50/60 Hz TYPICALLY12W (MOTORING) 4W (RESET CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED 14 V A 12 / 4 W 4 A.C. 250V 6(3)A 5 6 TF 72 °C CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET ­ 30...+50 °C CONTINUOUS ELECTRICAL THERMAL RELEASE (MUST BE FITTED FITTED TO DUCTING FOR DAMPER OPERATION). NON ETR VERSION AVAILABLE ON REQUEST (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Mode 9 PTC (Pneumatic Operation) Air On ­ Damper opens. Air Off ­ Spring closure. Release time 2 ­ 4 secs. Reset time 2 ­ 4 secs. Air inlet ­ 6mm dia. quick fit coupling. 74 °C Pneumatic Thermal Link (PTR). (PTR not supplied on Vent/Shield.) General (Electrical) One metre of halogen free low smoke and fume electric cable is also included with Control Modes 1, 5 and 6 for convenience of on site wiring. This also provides the distinct safety advantage of all electrics terminating outside the duct, eliminating potential in-duct fire hazards from wiring faults. Air pressure 5.5 ­ 8.0 bar. Air consumption to reset @ 5.5 ­ 8.0 bar. Air consumption to reset @ 5.5 bar ­ 535CC. External mechanical position indicator. Test operation by removing fusible link element. The Electrical Thermal Release is prewired with 0.5m halogen free low smoke and fume cabling to Control Modes 5 and 6. (Not supplied on Vent/Shield). A Manual test switch fitted on the ETR allows periodic operation of damper simulating actual fail-safe release under smoke/fire conditions. (Prewired Connection boxes available as factory fitted option.) Control Modes 5 and 6 are available without the ETR where thermal operation is not required. (This would not comply with BS 5588 Part 9 on Smoke/Shield.) www.actionair.co.uk 5 Smoke/Shield PTCTM Control Mode Details Control Mode 5 PTC and Control Mode 6 PTC Control Mode 5 PTC and Control Mode 6 PTC 60 seconds MAX Reset/ 20 seconds Release operation. These series of control modes achieve 60 seconds to drive to the end position, with a 20 second spring return time. This brings Actionair dampers in line with imminent European standardisation for fire and smoke control. As with all PTC modes, this series uses the snaplockTM interface. Fire rated dampers are primarily designed to be fitted into a wall or floor, and the interface displaces the mode from the line of the wall. Dampers may be installed and finally the mode removed from storage for easy fitting, thus preventing damage to the mode before it is required. End switches and LSF cable are provided as standard on all Smoke/Shield and Vent/Shield M5 PTC M6 PTC M5 PTC Vent M6 PTC Vent M5 PTC NON ETR M6 PTC NON ETR 24V 10W (12.5 VA), end switches SPDT 250V 6(3)A 230V 12W (14 VA), 230V 12W (14 VA), 230V 12W (14 VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A 24V 10W (12.5VA), end switches SPDT 250V 6(3)A 24V 10W (12.5VA), , end switches SPDT 250V 6(3)A XNNN00015 XNNN00016 XNNN00019 XNNN00020 XNNN00017 XNNN00018 XNNN00021 XNNN00022 Smoke/Shield Thermal Release / Power Off ­ Fail-safe Close* Smoke/Shield Thermal Release / Power Off ­ Fail-safe Close* Vent/Shield Vent/Shield Thermal Release / Power Off ­ Fail-safe Open* Thermal Release / Power Off ­ Fail-safe Open* modes. Versions are available to allow fail-safe close for fire safety (Smoke/Shield) or fail-safe open for smoke extract (Vent/Shield). The Electro Thermal Release (ETR) supplied for fire damper use has an integral fail-safe device to ensure that it is installed into the ductwork correctly. ETR units are not supplied with Vent/Shield, because these are designed to fail-safe open. End switches are provided with each mode, so that damper Reset and Release positions may be monitored. The mode is permanently attached to the mechanism driving the damper blades. Control Mode 9 PTC This mode has been developed to provide pneumatic operation of the damper and is available in spring return versions for fail-safe operation. A Pneumatic Thermal Release assembly (PTR) is available (Smoke/Shield only) to react to fire conditions. As with all PTC actuators, this series uses the snaplockTM interface. Switch box and solenoid accessories available. M9 PTC Pneumatic Thermal Release / Air Off ­ Fail-safe Close XNNN00300 M9 PTC Vent Pneumatic Thermal Release / Air Off ­ Fail-safe Open XNNN00303 Smoke/Shield Power Off ­ Fail-safe Close Smoke/Shield Power Off ­ Fail-safe Close Vent/Shield Vent/Shield Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open M5 PTC Vent NON ETR 24V 10W (12.5VA), end switches SPDT 250V 6(3)A M6 PTC Vent NON ETR 230V 12W (14 VA), *Smoke/Shield Control Modes M5 PTC and M6 PTC are supplied as standard with the Electrical Thermal Release (ETR) (Not fitted to Vent/Shield). The units Fail-safe by means of the unique and patented ETR device which operates at 72 °C, or if the power supply is off/interrupted. Complying with BS 5588 Part 9 1999. Non ETR versions Fail-safe when the power is off/interrupted. Control Mode 5 ­ 3P PTC Control Mode 5 ­ 3P PTC with additional facility for third (control) Position. This 3 position control mode allows a damper to be moved to both the reset and release position, with the additional facility to move the damper to a third control position. The mode is given a 2-10V d.c. signal, defining the position that the damper needs to be set at. A return signal of 2-10V d.c. is provided to allow monitoring of position. Smoke/Shield and Vent/Shield M5-3P PTC M5-3P PTC NON ETR M5-3P PTC Vent 24V 7W (10VA) end switches SPDT 250V 6(3)A 24V 7W (10VA) end switches SPDT 250V 6(3)A 24V 7W (10VA) end switches SPDT 250V 6(3)A XNNN00289 XNNN00291 XNNN00292 XNNN00293 Smoke/Shield Thermal Release / Power Off ­ Fail-safe Close 2-10V Set Position Smoke/Shield Power Off ­ Fail-safe Close Vent/Shield Vent/Shield Power Off ­ Fail-safe Open 2-10V Set Position 2-10V Set Position Thermal Release / Power Off ­ Fail-safe Open 2-10V Set Position To support this actuator and allow positioning to be set local to the damper, Actionair have developed the M5-3P-CMS control unit. As with all PTC modes, this series uses the snaplockTM interface. Fire rated dampers are primarily designed to be fitted into a wall or floor, and the interface displaces the mode from the line of the wall. Dampers may be installed and then the mode removed from storage for easy fitting, thus preventing damage to the mode before it is required. End switches, LSF cable, and Electro Thermal Release (ETR) are provided as standard (not fitted on Vent/Shield). Versions are available to allow fail-safe close for fire safety or fail-safe open for smoke venting. M5-3P PTC Vent NON ETR 24V 7W (10VA) end switches SPDT 250V 6(3)A Smoke/Shield Control Modes M5 ­3P PTC are supplied with the Electrical Thermal Release (ETR) (Not fitted to Vent/Shield). The units Fail-safe by means of the unique and patented ETR device which operates at 72 °C, or if the power supply is off/interrupted. Complying with BS 5588 Part 9 1999. Non ETR versions Fail-safe when the power is off/interrupted. Control Mode 5 ­ 2P PTC and Control Mode 6 ­ 2P PTC Drive open / Drive closed. 60 seconds operation This 2 position control mode has been developed to provide drive open/drive closed damper operation and it brings Actionair dampers in line with imminent European Standardisation for fire and smoke control, where for a given smoke control philosophy, or smoke source, a damper may be required to open or close to vent or contain the smoke. This is a radical alternative to the traditional spring return actuator, where upon power failure, instead of moving to fail-safe position, it remains in its desired emergency position. For any smoke control emergency situation, this is an absolute necessity. These modes do not have ETRs. Smoke/Shield and Vent/Shield M5-2P PTC M6-2P PTC 24V 12W (18VA), 230V 8W (15VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A XNNN00296 XNNN00297 As with all PTC actuators, this series uses the snaplockTM interface. All modes have LSF cables. Versions are available combined with protective enclosures (Hot/Shield) to provide further protection for 60 mins at 300 °C or 30 mins at 600 °C. 6 www.actionair.co.uk Smoke/Shield PTCTM Damper Installation and Control Mode Fitting STD RHD Actuator Position Control Mode 5/6 shown Control Mode 5/6 shown Transit Plate Step 1 Install the Smoke/Shield PTCTM Automatic Smoke and Fire Damper (complete with factory fitted damper drive shroud and transit plate) into the structure, connect and fit standard ductwork to damper spigots. Remove transit plate and discard. (Care must be taken when back filling to ensure that the snaplockTM retaining pin location hole and the entry slot of the damper drive shroud is clear of builders work debris). Step 2 Slide the snaplockTM Drive Interface into the damper drive shroud, `snaplockTM' into position, The `snaplockTM' feature provides a user friendly, easy and secure direct connection. It comes pre-set to enable direct fit to Smoke/Vent/Shield damper. LHD STD RHD STD RHD LHD Step 3 (Control Modes 5 and 6) Identify location for the Electrical Thermal Release (not required on Vent/Shield). Ideally, this should be fitted to the top half of the duct, adjacent to the control mode. Fit the self adhesive drilling template (supplied) in this position. Drill holes as detailed on the template. Using the 2 fixing screws provided, secure the Electrical Thermal Release to the duct. Connect electrically, and test operation. As a safety feature the actuator will only operate if the ETR is correctly fitted to the duct. Note: Non ETR version available. Step 3 (Control Mode 1) Smoke/Shield only SMOKE/SHIELD DAMPER TOP BOWDEN CABLE 315 ± 20mm MECHANICAL FUSIBLE LINK Step 3 (Control Mode 9) FLOW RESTRICTOR AIR SUPPLY INLET SMOKE/SHIELD DAMPER 5mm PNEUMATIC THERMAL RELEASE 108 40 ± *75mm 130mm Open Closed 130mm *This dimension will vary on Circular Damper. Select dimension to give smoothest radius on bowden cable. 4mm NYLON TUBING 500mm LENGTH 135mm Mark the Fusible Link position on the duct as dimensioned in the left hand diagram. Fit the self adhesive drilling template (supplied) in this position. Drill holes as detailed on template. Using the 2 fixing screws provided, secure the Fusible Link to the duct. Reset Damper using a 14mm A/F spanner, clockwise 1/4 turn. Test unit by simply unscrewing wing nut ­ Damper releases. For ductless installations a suitable sized plate or bracket must be fitted to the installation to allow the fitting of the Fusible Link. As a safety feature the Control Mode will only operate if the Fusible Link is correctly fitted to the duct. 1. Select position for PTR. (Smoke/Shield only). Ideally this should be in the top half of the duct and sufficiently close to the actuator to allow easy connection of the 4mm diameter nylon tube supplied. 2. Drill hole in selected position using a 30mm diameter hole cutter, removing any sharp edges. 3. Position PTR and drill the 4 off 3mm diameter fixing holes. 4. Remove PTR and apply approved fire retardant sealant on the duct around the hole. 5. Refit PTR and secure with the 4 off Pozi head screws provided. 6. Connect 4mm diameter tube to actuator and PTR. 7. Connect 6mm diameter tube to input side of PTR. 8. Connect air supply. Damper opens fully. 9. Test operation. www.actionair.co.uk 7 Smoke/Shield PTCTM Installation Systems Popular types of Installation Frame that are available. DWFXTM (DRY WALL FIX) Installation System Typically for installation into Dry Wall, Stud Partitions. HEVAC / HVCA Galvanised Steel Installation Frames Typically for installation into Blockwork, Concrete walls and floors. DWFX -F DWFX -C DWFX-F Dimensional Data See page 12 and 13. Specification The Actionair DWFX-F installation method is BRE Tested to EN1366-2 for 90 minutes. (BRE test report 220895). Classification (ref BRE assessment 225285). Specification The Actionair DWFX-C installation method is BRE Tested to BS476 pt 20 for 2 hours. (BRE test report 212065). Suitable for DWFX-C Dimensional Data 50 50 50 · · Actionair Smoke/Shield ES60/E90 · Actionair Hot/Shield ES60/E90 Actionair Fire/Shield E90 The Actionair DWFX-F consists of a 1.2 mm galvanised steel peripheral flange with 50mm x 50mm x 3mm steel angle cleats with 14 x 24 oval slots, welded to damper casing for drop rod support. · Actionair Fire/Shield · Actionair Smoke/Shield · Actionair Hot/Shield The Actionair DWFX-C consists of 50mm x 50mm x 3mm steel angle cleats with 14 x 24mm oval slots. Fully welded to damper casing for drop rod support prior to wall construction. 14 Comprehensive literature, outlining installation and features, is available for our DWFX systems. Go to our website:www.actionair.co.uk to view or download these as PDF files. 24 8 www.actionair.co.uk Smoke/Shield PTCTM HEVAC / HVCA Galvanised Steel Installation Frames Galvanised steel building ties permit stable handling, ease of transport and convenience of building in to the surrounding structure. supplied in sections with the installation frame supplied in kit-form, AAF Drg.8057. A drawing and method statement will be supplied for the assembly to be fitted on site. The maximum size of kit-form installation frames will be to accommodate a four section assembly. a. In brick or blockwork walls the tabs shall be bent out and solidly built into the mortar joints between the brick or blockwork. b. In the case of reinforced concrete walls and floors, the tabs shall be bent out and tied with wire to the reinforcing bars which will be deliberately left protruding into the opening. The gap between the installation frame and builders work shall be backfilled with mortar or concrete on both sides of the flange. Adjacent frame assemblies must be separated by builders work of a minimum thickness of 225mm (between installation frame upstand flanges) unless approval has been previously obtained from the appropriate Authority. For installations below this dimension please refer to Actionair Sales office. Galvanised Steel Installation Frames (as required by HVC 6/5/83 Rev.1 July 1999.) Installation frames are delivered to site as a complete assembly with the appropriate Fire/Shield Damper fitted therein. The frame shall be installed centrally in the thickness of a brick, blockwork or concrete surrounding wall or floor, or in the case of thick walls or floors, so that the centre line of the frame is at least 50mm away from the nearest face of the wall or floor in which the assembly is mounted. The four tabs (building tie) forming each fixing point shall provide a positive fixing into the structure. Multiple assembly dampers up to 1500 x 1500 or 2000 x 1000 can be fitted into fully assembled installation frames and delivered as one piece. Dampers in excess of this size will be In no case shall the HEVAC/HVCA frame and damper assembly be held in position merely by the adjacent ductwork, and it should be noted that in reinforced concrete structures (especially floors), it will not be sufficient to only backfill between the damper installation frame and the surrounding opening with mortar or fine aggregate concrete mix without provision for tying in the frame to the surrounding reinforced concrete structure. Approved Installations A binder containing approved installation illustrations is now available. (Refer to Actionair Sales Office or visit our website, www.actionair.co.uk The illustrations are under the heading PRODUCTS DRAWINGS.) Although the included methods have been tested and assessed, it is recommend, that these, as with all installation methods must be confirmed with Building Control / Local Authority prior to manufacture. Actionair can also provide applications of other proposed methods of installation, please contact our Sales Office to discuss your specific requirements. These again are the responsibility of the client to ensure that these are acceptable to Building Control / Local Authority before construction commences. www.actionair.co.uk 9 Smoke/Shield PTCTM Accessories Electrical A range of indicator panels, push button switches and damper test units are also available. The housing for these units are manufactured in rigid ABS plastic. The Damper Connection Box is in galvanised steel. Damper Test Unit Reset and release indication. Spring bias (power OFF) test switch. Power normally ON. DTU24 DTU120 DTU230 DSI24 24V AC/DC 120V AC 230V AC 24V AC/DC 120V AC 230V AC 24V AC/DC 120V AC 230V AC XNNN00010 XNNN00305 DNNN00029 DPNN00412 XNNN00308 DPNN00413 XNNN00309 XNNN00310 XNNN00311 indication is provided. Operation is by push button to close and twist to re-open damper. Tested to BS EN 61010 -1: 2001 and is CE compliant. IP44 rated. Operating range 5 - 40 degrees C. Damper Status Indicator Reset and release indication. DSI120 DSI230 DCU24 Damper Control Unit Switch ON/OFF function. Reset and release indication. DCU120 DCU230 Damper Release and Indication Module (DRIM) This is designed for control and monitoring of the electrically operated Smoke Shield PTCTM Fire and Smoke dampers. It will operate from 24, 120 or 230 volt supplies, 50 or 60 Hz. Selection of the operating voltage is by use of internal links on the PCB, prior to installation and connection of actuator and supply. The DRIM may be used singly to provide local damper control, or in pairs to provide control from either side of a damper. It can also operate 2 actuators when dampers are provided in 2 multiple sections LED position and operation DRIM M52PDCU M62PDCU DCB 24V ­ 230V AC/DC 24V AC/DC 230V AC 24V ­ 230V AC/DC XNNN00589 XNNN00313 XNNN00314 XNNN00312 M5 and M6 ­ 2P Damper Control Unit Switch power open/power close. Open and closed indication. Damper Connection Box (All Voltages). M5 ­ 3P ­ CMS Control Unit M53PCMS 24V AC/DC XNNN00315 Pneumatic Solenoid, (24, 120, or 230 volt). EEXD Solenoid, (24, 120, or 230 volt). Damper Status Beacon. Switchbox and Status Beacon. Zone 2 Switchbox and Status Beacon. 24 ­ 230V AC/DC Various 10 www.actionair.co.uk Smoke/Shield PTCTM Control Mode Dimensions and Orientation Mode 1 (Smoke/Shield only) Smoke/Shield PTCTM Control Modes are located outside of the ductwork for ease of access and installation. 5 All dimension are in millimetres 130 INPUT SHAFT 108 14 70 25 Snaplock RETAINING PIN LOCATION HOLE Modes 5 and 6 Three position 180° (Pivotable Control Mode) Smoke/Shield PTCTM Control Modes are located outside of the ductwork for ease of access and installation. Control Modes 5 and 6 can be fitted in any one of three orientations i.e. Vertically down (Position 1) Horizontally (Position 2), or Vertically up (Position 3). This can be simply and easily carried out on site, by repositioning the Location Plate (see page 2) and Control Mode on to the snaplockTM Drive Interface. This flexibility ensures that the damper and control mode require the minimal amount of room. (Supplied in position 2 as standard.) 84 260 Position 3 28 108 Position 2 248 Position 1 12 100 112 56 Mode 9 Pneumatic Control Smoke/Shield PTCTM Control Modes are located outside of the ductwork for ease of access and installation. 143 130 222 SWITCHBOX / STATUS BEACON Optional Extra CABLE ENTRY POINTS 222 55 59 SOLENOID Optional Extra 108 255 160 115 95 155 102 www.actionair.co.uk 11 Smoke/Shield PTCTM Dimensional Data For Rectangular Dampers spigots are 5mm under duct size. (For further details please refer to Actionair Sales Office.) Basic Dampers Dampers with Installation Systems Dampers with DWFX-F HEVAC / HVCA IF OVERALL WIDTH OF INSTALLATION FRAME IS 316mm OVERALL HEIGHT OF INSTALLATION FRAME IS 340mm Rectangular Dampers Series 501 and 1501 For Ducts with widths of 100 ­ 150mm For Ducts with heights of 100 ­ 150mm OVERALL FLANGE WIDTH = 370mm OVERALL FLANGE HEIGHT = 395mm 25 = 100 - 150 DUCT WIDTH = 25 50 90 50 110 DUCT HEIGHT 100 - 150 200 25 85 200 28 200 38 38 78 38 38 For Ducts with widths of 151 ­ 199mm For Ducts with heights of 151 ­ 199mm OVERALL FLANGE WIDTH = 420mm OVERALL FLANGE HEIGHT = 445mm OVERALL WIDTH OF INSTALLATION FRAME IS 366mm OVERALL HEIGHT OF INSTALLATION FRAME IS 390MM 90 25 50 = 151 - 199 DUCT WIDTH = 25 50 110 DUCT HEIGHT 151 - 199 250 25 85 250 28 250 38 38 78 38 38 For Ducts with widths and heights of 200 ­ 1000mm OVERALL FLANGE WIDTH = DUCT WIDTH + 170mm OVERALL FLANGE HEIGHT = DUCT HEIGHT + 195mm OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 116mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT HEIGHT + 140MM 90 25 200 -1000 DUCT WIDTH 25 50 50 110 DUCT HEIGHT DUCT HEIGHT 200 - 1000 200 - 1000 200 - 1000 200 - 1000 25 28 38 78 38 12 www.actionair.co.uk 85 57 200 - 1000 83 57 250 83 57 200 83 Smoke/Shield PTCTM For Circular and Flat Oval Dampers spigots are 3mm under duct size. (For further details please refer to Actionair Sales Office.) Basic Dampers Dampers with Installation Systems Dampers with DWFX-F HEVAC / HVCA IF OVERALL WIDTH OF INSTALLATION FRAME IS 316mm OVERALL HEIGHT OF INSTALLATION FRAME IS 340mm Circular Dampers Series 601 and 1601 DUCT DIA 100 - 150 OVERALL FLANGE WIDTH = 370mm OVERALL FLANGE HEIGHT = 395MM 50 50 = 110 = = 90 108 OVERALL WIDTH OF INSTALLATION FRAME IS 366mm OVERALL HEIGHT OF INSTALLATION FRAME IS 390mm DUCT DIAMETER 25 28 25 CIRCULAR CIRCULAR 100 - 150 200 25 25 200 25 65 38 78 38 65 OVERALL FLANGE WIDTH = 420mm OVERALL FLANGE HEIGHT = 445mm = = DUCT DIA 151 - 199 50 = 50 110 85 82 = 90 108 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT DIA + 166mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT DIA + 190mm DUCT DIAMETER 25 28 25 CIRCULAR CIRCULAR 151 - 199 250 25 = 25 250 25 65 38 78 38 65 OVERALL FLANGE WIDTH = DUCT DIA. + 220mm OVERALL FLANGE HEIGHT = DUCT DIA. + 245mm 50 75 DUCT DIA 200 - 950 50 50 50 110 85 82 90 108 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 166mm OVERALL HEIGHT OF INSTALLATION FRAME IS DUCT HEIGHT +190mm DIA + 50mm* DUCT DIAMETER 25 28 25 25 Duct FOR 951 ­ 1000mm DUCT DIM + 30mm CIRCULAR CIRCULAR 200 - 950 Duct 25 50 25 65 38 78 38 65 OVERALL FLANGE WIDTH = DUCT WIIDTH + 220mm OVERALL FLANGE HEIGHT = DUCT HEIGHT + 245mm Flat Oval Dampers Series 701 and 1701 50 DUCT WIDTH 300 ­ 950 * 50 50 50 110 85 82 90 108 82 75 DUCT HEIGHT +50MM 25 28 50 25 FLAT OVAL FLAT OVAL 200 - 500 DUCT HEIGHT 25 85 25 DUCT WIDTH + 50mm* 25 65 38 78 38 65 FOR 951 ­ 1000mm DUCT DIM + 30mm * www.actionair.co.uk 13 Smoke/Shield PTCTM Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of Smoke/Shield PTC Automatic Smoke and Fire Control Dampers. A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. This independent test facility is approved under the NAMAS Scheme. From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Graph 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Graph 2) The graph is the result of a full range of acoustic tests on Smoke/Shield PTCTM Automatic Smoke and Fire Control Dampers with the blades set in their fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) can be obtained from Table 1. Pressure Drop Vs Velocity Graph 1 100 90 80 70 60 50 40 30 EXAMPLE LINE 20 PRESSURE DROP (Pa) 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 15 VELOCITY (m/s) Example: Duct with a design velocity of 8 m/sec. Smoke/Shield PTC Damper Series 501 fully open. Pressure Drop = 21 Pa (Graph 1). Multiply Velocity x Pressure Drop 8 x 21 = 168. From Sound Power Graph (Graph 2) plot 168 on horizontal Velocity/Pressure axis against 501 outlet (induct) graph to obtain 47 dBW on Vertical Sound Power Level Axis. Add or subtract corrections to the 47 dBW to provide full spectrum analysis using appropriate Correction Table. 14 www.actionair.co.uk TYP E5 01 TYP E6 01 Smoke/Shield PTCTM Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) Graph 2 90 Damper Leakage Graph 3 Smoke/Shield PTCTM and Vent/Shield PTCTM closed blade leakage as tested on a damper 1000mm wide x 1000mm high. Leakage data at Ambient temperature (Cold Smoke). 80 1500 70 SOUND POWER LEVEL (dBW) 60 6 50 EXAMPLE LINE 01 O U T 1 50 O U E TL T (IN PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) T LE (IN D U C T) C DU T) 1200 1000 500 40 30 5 01 BR E AK O U T 300 250 200 150 20 60 1 B A RE K O U T 10 120 100 0 4000 5000 6000 7000 8000 9000 10000 400 500 600 700 800 900 1000 40 50 60 70 80 90 100 2000 3000 200 300 10 20 30 VELOCITY X PRESSURE DROP (m/s Pa) Correction Tables Table 1 Smoke/Shield PTCTM Outlet (Induct) Spectrum Corrections Octave Band Series 501 Series 601 Table 2 Smoke/Shield PTCTM Breakout Spectrum Corrections Octave Band Series 501 Series 601 Hz dB dB 63 8 6 125 11 10 250 9 8 500 6 4 1k -3 -3 2k -6 -3 4k -14 -11 8k -17 -14 Hz dB dB 63 5 9 125 4 4 250 5 4 500 5 5 1k 3 3 2k 1 1 4k -3 -3 8k -5 -6 70 50 5 10 20 30 40 50 100 LEAKAGE (I/s) The Smoke/Shield PTCTM Damper has been fire tested to BS ISO 10294-1 and BS EN 1366-2. It achieved ES classification in accordance with BS ISO 10294-2:1999. ES classification allows a maximum of 200m3/ Hr/m2 (corrected to 20 °C) hot gas leakage throughout the test at 300Pa pressure differential across the damper. www.actionair.co.uk 15 Smoke/Shield PTCTM Actionpac Damper Control Systems The Actionpac LNS3 system is designed to protect life and property from damage caused by smoke and fire, by providing the means to:­ Actionpac EMS (Standard and EMB (Bespoke) Electro-Mechanical Control and Monitoring Systems EMS Actionpac (Standard) The EMS Control Panels are of standard construction for the control and monitoring of Mode 5 or mode 6 damper actuators in groups of 12, 24 or 36. EMB Actionpac (Bespoke) The EMB Control Panels typically consists of the appropriate number of switches to provide individual or group control, LED indication for status monitoring and all necessary relays and timers to comply with the customer needs for fully or semi automatic damper operation. The EMB panels are purposely manufactured for any particular project to suit specific client requirements. · Compartmentalise fire zones. · Reduce the spread of smoke and fire. · Keep escape routes and fire-fighting access open. · Allow pressurisation and smoke extract by combined operation of dampers and fans. Benefits · Completely flexible to meet practically any building's damper requirements The Actionpac LNS3 system represents a new generation of smoke/fire damper control. The system has been designed with the user in mind, providing an advanced tool that simplifies installation and commissioning of smoke/fire dampers and peripheral devices. The Panel PC operates on a WindowsTM platform making it universally accepted and utilises solid state technology for optimum reliability. It's server architecture delivers new benefits such as reduced commissioning time, simplified operation and scope for future growth. · 3 levels of alarm priority Panel PC driven system with real-time graphic displays · Panel PC utilises solid state technology for optimum reliability · Operates on windowsTM platform ­ user friendly · Full configuration and diagnostics from Panel PC · Automatic scheduled Damper testing · Allows for exact location of devices in text · Multiple wiring configurations to include Radial or Loop Topology · Damper operational count provided · Flexibility to accommodate any last minute changes to strateg, zones, damper additions, damper locations etc. Detailed information available in separate Actionpac sales leaflets. · Guaranteed input response times of &lt;10 seconds on a 512 damper system to meet the new draft BS EN 12101-9. Detailed information available in separate Actionpac LNS 3 sales leaflet. 16 www.actionair.co.uk Smoke/Shield PTCTM General Schematic of Actionpac LNS Damper Control System Panel PC Data Network B.M.S. Vent Panel SFDI SFDI SFDI OUTPUTS DX - 8 SFDI Smoke Fire Damper Interface One per Control Mode / Damper Section Damper Control Mode* Device located in Panel on Network INPUTS SFDI DX - 8 Digital Input / Output Device Interface to Fire System BMS Inputs Fire Alarm Inputs To additional devices as required Fireman's Switch Inputs Supply to each SFDI must be via a switched fused spur. For further application, technical and pricing information, please refer to Actionair Sales Office. www.actionair.co.uk 17 Smoke/Shield PTCTM Specification Smoke/Shield PTCTM Proportional Torque Control Automatic Smoke and Fire Dampers with 75mm x 0.5mm thick stainless steel aerodynamic interlocking blades incorporating synthetic seal, with steel blade end bearings and peripheral gasketting. Housed in a galvanised steel fully welded 1.2mm spigotted casing suitable for square, rectangular, circular or flat oval connections. All PTCTM Dampers are supplied with the blades in the closed position to prevent the ingress of dirt an dust. The totally enclosed precise movement opposed blade drive shall be positioned out of airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplockTM drive interface mechanism, which is totally independent of the ductwork. Smoke/Shield PTCTM Automatic Smoke and Fire Dampers with their appropriate control modes shall have spring Fail-Safe Closed operation. Smoke/Shield PTCTM Damper and selected Control Mode (M1,M5, M6 and M9) as supplied by Actionair. Vent/Shield PTCTM Proportional Torque Control Automatic S m o k e Release Dampers with 7 5 m m x 0.5mm thick stainless steel aerodynamic blades incorporating synthetic seal, with steel blade end bearings and peripheral gasketting. Housed in a galvanised steel fully welded spigotted casing suitable for square, rectangular, circular or flat oval duct connections. The totally enclosed precise movement opposed blade drive shall be positioned out of airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplockTM drive interface mechanism, which is totally independent of the ductwork. Vent/Shield PTCTM Automatic Smoke Release Dampers with their appropriate control modes shall have spring Fail-Safe Open operation. Vent/Shield PTCTM Damper and selected Control Modes as supplied by Actionair. Approvals Approved by The Loss Prevention Council for use in up to 4 hour constructions. Refer to Installation and Maintenance Guide on our website for precise details. The Smoke/Shield PTCTM Damper tested and assessed to BS ISO 10294-1, BS EN 1366-2 and BS 476 pt. 20. It achieved ES classification in accordance with BS ISO 10294-2:1999. Low gas/smoke and fire integrity to Classification ES in vertical and horizontal test installations. An LPCB approved product, compliant to the new Loss Prevention Council Design Guide for Fire Protection of Buildings. Fire tested in vertical and horizontal applications under dynamic conditions by The Loss Prevention Council. Corrosion tested to LPS 1162. Complies with the latest DW 144 casing leakage specification. The Electrical Control Modes satisfy the requirements of EN 50081-1 and EN 50082-1 electro magnetic compatibility. Maintenance The Smoke/Shield PTCTM Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions this may need to be performed more regularly based on experience gained from previous inspections. Smoke/Shield PTCTM A Fire Rated Damper in accordance with British Standard 5588: Part 9: 1999 should be held in the Open Position by means of a Thermally Actuated Device set to operate at approximately 74 °C. Smoke/Shield PTCTM Automatic Smoke and Fire Control Dampers are Fire Rated Dampers as they are held in the Reset (Open) Position by a Thermally Actuated Device (Control Mode 1 ­ Mechanical Fusible Link, Control Modes 5 & 6 ­ Electrical Thermal Release ­ Mode 9 ­ Mechanical Fusible Link) operating at a temperature of approximately 72° C ± 4 °C. Optional higher rated links are available, refer to Actionair Technical Sales Office. Note: Thermally activated devices are not supplied with Vent/Shield Control Modes as standard. Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. The information contained herein is subject to change without notice due to continuing research and development. Quality Assurance Certification No.17 Assessed to ISO 9001 18 www.actionair.co.uk Smoke/Shield PTCTM Approximate Weights (Kg) Square or Circular Duct Size (mm) Series 501 Square Series 501 Square + I/F Series 601 Circular Series 601 Circular + I/F 100 150 200 250 3.4 6.2 5.3 8.5 3.4 6.2 5.3 8.5 3.4 6.2 5.3 4.2 7.4 6.1 300 350 400 450 500 550 600 650 700 4.8 5.6 6.5 7.4 8.6 750 800 850 900 950 1000 9.6 10.8 12.4 13.6 14.9 16.2 17.7 19.2 20.8 23.5 8.7 10.3 11.9 13.2 14.6 16.3 18.5 20.5 22.1 24.0 25.9 28.1 30.3 32.4 34.5 7.2 8.4 9.6 11.2 12.6 14.0 15.9 17.5 19.1 20.7 22.5 24.3 26.2 29.3 32.1 8.5 10.0 11.9 13.7 15.4 17.1 19.2 21.8 24.0 26.0 28.2 30.4 32.8 35.3 37.8 40.3 43.1 Control Mode 1 (Smoke/Shield only) (including drive interface) 4.1Kg Control Modes 5, 5 - 3P, 5 - 2P, 6, 6 - 2P and 9 (including drive interface) 4.4Kg Ordering Information Example Quantity 3 Series SS501/PTC Fixing Options Duct Size IF 600(W) x 450(H) Control Mode M5 Accessories Number of units required SS 501/PTC Smoke/Shield PTCTM Square or Rectangular (Fail-safe closed). 1. DWFX-F Dry Wall Fixing System Flange plus Cleats 2. DWFX-C Dry Wall Fixing System Cleats 3. IF HEVAC / HVCA Installation Frame 4. Other Special Fixings M1 PTC Manual System M5 PTC 24V 10W (12.5VA) M6 PTC 230V 12W (14VA) M5 PTC Vent NON ETR 24V 10W (12.5VA) M6 PTC Vent NON ETR 230V 12W (14VA) M5 PTC NON ETR 24V 10W (12.5VA) M6 PTC NON ETR 230V 12W (14VA) M5 PTC Vent 24V 10W (12.5VA) M6 PTC Vent 230V 12W (14VA) M5-2P ON/OFF 24V 7W (10VA) M6-2P ON/OFF 230V 8W (12.5VA) M5-3P PTC 24V 7W (10VA) M5-3P PTC Vent NON ETR 24V 7W (10VA) M5-3P PTC NON ETR 24V 7W (10VA) M5-3P PTC Vent 24V 7W (10VA) M9 PTC Pneumatic Operation M9 PTC Vent NON PTR Pneumatic Operation Electrical 1. DTU Damper Test Unit Damper Test Unit For Control Modes. Spring bias test switch providing illuminated reset and release status 2. DSI Damper Status Indicator Reset and Release Indication 3. DCU Damper Control Unit Damper Control Unit for Control Modes. Switch ON/OFF function, reset and release indication 4. DRIM Damper Release and Indication Module 5. 2PDCU M5 and M6 -2P DCU Switch Power Open/Power Close. Open and Closed Indication 6. DCB Connection Box For Control Modes 1, 5 and 6 (see page 10 for above) Pneumatic 24 Volt Solenoid, (24, 120, or 230 volt). Status Beacon, Switchbox and Status Beacon. PTR XNNN05017 Actionpac Damper Control Systems (See page 16) SS 601/PTC Smoke/Shield PTCTM Circular (Fail-safe closed). SS 701/PTC Smoke/Shield PTCTM Flat Oval (Fail-safe closed). VS 1501/PTC Vent/Shield PTCTM Square or Rectangular (Fail-safe open). VS 1601/PTC Vent/Shield PTCTM Circular (Fail-safe open). VS 1701/PTC Vent/Shield PTCTM Flat Oval (Fail-safe open). www.actionair.co.uk 19 Smoke/Shield PTCTM Ruskin Air Management Limited a BS EN ISO 9000 registered company The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information pur poses only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. New Product Available Now! New Product Available Now! CSS DAMPER CSS Smoke ES Rated Fire Damper CIRCULAIR Series Air Balancing Dampers Ruskin Air Management Limited South Street, Whitstable, Kent CT5 3DU England. Tel: 01227 276100 Fax: 01227 264262 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[32]=new Array("http://www.actionair.co.uk/pdf/energy.pdf","energy.pdf","","February 2003 Energy/Shield Actionair Energy/Shield Heavy Duty Air Control and Shut-off Dampers Features and Design Guide Damper suitable for systems requiring air control and very low closed blade leakage characteristics. Suitable for high pressure and high velocity applications. Available in Flanged or Spigotted type casings. Product Range Series Airbalance Aluminium bladed dampers for air control and system balancing. Series Airstop Aluminium bladed dampers for air control, system balancing and low closed blade leakage. Series Airtight Stainless Steel bladed dampers for air control, system balancing and low closed blade leakage. Dampers Designed and Built in Britain Patent Nos. pending. Energy/Shield The Range The Energy/Shield range of quality engineered dampers are suitable for air conditioning and ventilation systems requiring air control and very low closed blade leakage characteristics, especially those involving high pressure and high velocity applications. Blade Features Series Airbalance Aluminium Series Airbalance for air control and system balancing having reinforced aerodynamic aluminium blades, only in mill finish, within an all welded robust galvanised housing. Suitable for systems with a temperature range of ­20 °C through to +70 °C. These heavy duty, aerodynamic, precise movement, opposed blade dampers can be either factory fitted with manual, electric or pneumatic controls. Dampers can be supplied in a flanged style casing or complete with spigotted adaptor plates. Series Airstop Aluminium Application Parameters Energy/Shield Dampers are designed for application in normal dry filtered air systems. When required for a modulating function, or if exposed to fresh air intakes, and/or inclement conditions, the damper should be subject to a planned inspection programme. Series Airstop for air control, system balancing and low closed blade leakage characteristics having reinforced aerodynamic aluminium blades only, in mill finish with synthetic blade edge and side seals, within an all welded robust galvanised housing. Suitable for systems with a temperature range of 0 °C through to +70 °C. Energy/Shield Dampers to maximum width and height dimensions can be used where the operating total system pressure is up to 2000 Pascals and the duct velocities to 20 m/second. Series Airtight Stainless Steel Series Airtight for air control, system balancing and low closed blade leakage characteristics having reinforced aerodynamic double skin Type 1.4016 (430) Ferritic Stainless Steel blades with synthetic leading and trailing edge seals and double side seals within an all welded robust galvanised housing. Suitable for systems with a temperature of 0 °C through to +70 °C. Optional blade construction Type 1.4401 (316) Austenitic Stainless Steel. For specialist applications and parameters greater than those stated please refer to our Customer Service Office. 2 Energy/Shield Casings Features Blade Stability Blade stabilisers and tie bars are provided as standard on Series Airtight Dampers with widths greater than 1250mm and Series Airstop and Series Airbalance Dampers with widths greater than 1100mm. This eliminates bowing and/or distortion due to fan and system characteristics. Thus giving the obvious benefits of improved aerodynamic control and the absolute lowest possible air leakage in the fully shut off position for the Series Airstop and Airtight Dampers. The damper casing having a single penetration for the drive control shaft making these dampers suitable for inclusion into air distribution systems of Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B and C of HVCA Ductwork Specification DW144. Flanged A galvanised steel casing of all welded corner construction having peripheral flanges with pre-punched elongated corner holes to suit proprietary duct flanges. Optional stainless steel flanged casings are available in either Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic material. Spigotted Dampers can be factory fitted with galvanised spigotted adaptor plates for square, rectangular, circular and flat oval duct connections. As an option these spigotted adaptor plates are available in Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic Stainless Steel. Type SPG Circular Type FLA Square/Rectangular Type SPG Square/Rectangular Type SPG Flat Oval Series Airtight The semi-circular synthetic blade stabilisers are fixed to each side of the blade to form a complete circle. This allows the blade to be held rigidly between the vertical steel tie bars. Multiple Assemblies Square and rectangular casings are available in multiple module arrangements supplied complete with blanking strips for site fixing by others. Blade Drive Mechanism The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. 3 Energy/Shield Control Options 140 Technical Data Damper Torque Manual Quadrant Control (Option Q) Always fitted as standard consists of a dark brown steel handle, blade position locking facility and quadrant bracket with visual position indication. 100 6 183 25 31 62 The rotation of damper blades from the fully closed to the fully open position produces the greatest torque. The largest torque requirement is also dependent on the fan and system characteristics. Generally, Energy/Shield Dampers to a size range up to 0.25 square metres and 500mm diameter require no more than 15Nm torque. For larger dampers up to 1.5 square metres and 1000mm diameter require no more than 30Nm torque. For dampers above 1.5 square metres to our maximum of 2.25 square metres no more than 50Nm torque is required. The above torques are to rotate the damper blades from the fully closed to the fully open position against the recommended maximum total system pressure of 2000 pascals. Factory fitted Belimo Electrical Controls will be selected to suit the torque requirements of the damper. Electrical Controls (Option E) Factory fitted Belimo Actuators for 24V or 240V open/closed or spring return operation and 24V modulating are available. These will comply with EMC Directive 89/336/EEC. Extended Shaft Control (Option X) A solid 12.7mm diameter stainless steel shaft marked to provide visual blade indication complete with support bracket for attachment of couplings and/or linkages for motorisation by others. 12.7 DIA 58 Approximate Weight (Kg) Square/ Type FLA Type SPG Type SPG Circular Rectangular Circular Duct Size 60 27 200 300 400 4.0 6.2 9.0 11.8 15.1 18.6 22.6 26.8 31.6 5.0 8.5 11.6 14.2 19.1 24.2 29.4 33.6 38.2 6.8 11.5 16.3 21.0 29.1 37.1 45.2 53.2 61.3 127 500 600 700 Pneumatic Controls Factory fitted Pneumatic Actuators are available to suit specific client specification. 800 900 1000 For Type SPG Flat Oval weights please contact Customer Service Office. 4 Energy/Shield Dimensional Data Flanged Casing (Type FLA) 150 OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) (TYPE AIRSTOP = DUCT HEIGHT + 85mm) 20 16 13 Dia 40 DUCT WIDTH 40 8 8 Spigot Casing (Type SPG Rectangular) SPG rectangular spigots are supplied 5mm under duct size. 150 OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) (TYPE AIRSTOP = DUCT HEIGHT + 85mm) 1. Type FLA widths in any size from 200mm to 2000mm. Widths greater than 1500mm are restricted to a height of 1000mm. Type FLA heights from 200mm to 1500mm in 50mm increments. Heights greater than 1000mm are restricted to a width of 1500mm. 2. Type SPG rectangular widths in any size from 100mm to 2000mm. Widths greater than 1500mm are restricted to a height of 1000mm. Type SPG rectangular heights in any size from 100mm to 1500mm. Heights greater than 1000mm are restricted to a width of 1500mm. 3. Type SPG circular in any size from 100mm diameter to 1000mm diameter. 4. Type SPG flat oval widths in any size from 300mm to 2000mm. Type SPG flat oval heights in any size from 100mm to 500mm. 5. All dampers are suitable for either horizontal or vertical mounting. 6. Series Airtight Damper widths greater than 1250mm have blade stabilisers and 22mm square central vertical tie bars. Series Airstop and Airbalance damper widths greater than 1100mm have blade stabilisers and 22mm square central vertical tie bars. DUCT HEIGHT (IN 50mm INCREMENTS ONLY) 40 40 40 DUCT WIDTH 40 SPIGOTS SUPPLIED 5mm UNDER DUCT SIZE 100mm INCREMENTAL DUCT HEIGHT INTERMEDIATE DUCT HEIGHT 40 40 38 20 16 38 Spigot Casing (Type SPG Circular) SPG circular spigots are supplied 3mm under duct size. 150 OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) (TYPE AIRSTOP = DUCT HEIGHT + 85mm) 40 DUCT DIAMETER 40 65 65 Spigot Casing (Type SPG Flat Oval) SPG flat oval spigots are supplied 3mm under duct size. 150 OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) (TYPE AIRSTOP = DUCT HEIGHT + 85mm) SPIGOTS SUPPLIED 3mm UNDER DUCT SIZE 100mm INCREMENTAL DUCT HEIGHT DUCT HEIGHT 40 7. All overall damper widths are duct widths/diameters + 80mm. Type SPG intermediate duct heights/diameters selected from next larger 100mm incremental duct height with spigot heights being centrally positioned within overall damper height. Type SPG intermediate duct heights/diameters less than 200mm to 100mm minimum are selected from the 200mm incremental duct height with spigots being centrally positioned within overall damper height. 8. A square solid stainless steel drive shaft fitted to, or nearest to, central blade of damper for direct connection and interchangeability of all control options. Dampers must not be transported, stored or mounted in such a manner that the blades run vertically. 40 40 DUCT WIDTH 40 SPIGOTS SUPPLIED 3mm UNDER DUCT SIZE 100mm INCREMENTAL DUCT HEIGHT DUCT DIAMETER 40 40 65 65 5 Energy/Shield Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of the Energy/Shield Air Control and Shutoff Dampers. A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound Research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos., 4196, 4773, 4856, 4857 and 4954. This independent test facility is approved under the NAMAS Scheme. For a selection of duct velocity within Pressure Drop Vs Velocity 2000 3 ON N2 the operational parameters of the dampers a resultant pressure drop can be determined and the sum of these two components applied to the Velocity X Pressure Drop Vs Sound Power Level Graph. The graph is the result of a full range of acoustic tests on Energy/Shield Air Control and Shut-off Dampers with the blades set from fully open through positions 1, 2 and 3. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) is obtained. Example: Duct with a design velocity of 10 m/sec. Energy/Shield Damper fully open. Pressure Drop = 12.5 Pa (Table 1). Multiply Velocity X Pressure Drop 10 x 12.5 = 125 From Sound Power Graph (Table 2) plot 125 on the horizontal Velocity/Pressure on the outlet (induct) graph to obtain 62 dBW and similarly for breakout to obtain 48 dBW. Subtract corrections to provide full spectrum analysis. Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) 110 IO TI 400 300 N1 IO SOUND POWER LEVEL (dBW) 1000 900 800 700 600 500 PO SI PO SIT 100 90 80 ) CT DU (IN 200 PO SIT 70 EXAMPLE LINE ET TL OU UT KO EA BR PRESSURE DROP (Pa) 100 90 80 70 60 50 40 EN 60 50 30 20 40 OP 30 4000 5000 6000 7000 8000 9000 10000 400 500 600 700 800 900 1000 40 50 60 70 80 90 100 10 9 8 7 6 5 4 3 2 Table 2 VELOCITY X PRESSURE DROP (m/s Pa) 1 1 2 3 4 5 6 7 8 9 10 15 20 Energy/Shield Outlet (in duct) Octave band 63 125 250 OPEN 0 ­ 4 ­ 10 POSITION 1 ­ 7 ­ 17 ­ 21 POSITION 2 ­ 4 ­ 9 ­ 13 POSITION 3 ­ 14 ­ 18 ­ 21 DUCT VELOCITY (m/s) Spectrum Correction 500 1K 2K 4K ­ 12 ­ 16 ­ 21 ­ 27 ­ 23 ­ 26 ­ 29 ­ 33 ­ 17 ­ 19 ­ 20 ­ 25 ­ 20 ­ 19 ­ 17 ­ 22 4K ­ ­ ­ ­ 33 43 43 42 ­ ­ ­ ­ 8K 32 36 29 26 8K Table 1 Positions 1, 2 & 3 are blade positions as indicated on dampers fitted with Manual Quadrant Control. 6 Energy/Shield Breakout Spectrum Correction Octave band 63 125 250 500 1K 2K OPEN ­ 11 POSITION 1 ­ 16 POSITION 2 ­ 19 POSITION 3 ­ 28 ­6 ­ 13 ­ 16 ­ 25 ­3 ­ 12 ­ 19 ­ 25 ­ ­ ­ ­ 10 19 23 28 ­ ­ ­ ­ 17 25 26 31 ­ ­ ­ ­ 26 35 35 36 ­ ­ ­ ­ 38 45 51 42 20000 Hz dB dB dB dB Hz dB dB dB dB 30000 2000 3000 200 300 10 20 30 EXAMPLE LINE Energy/Shield Damper Leakage Energy/Shield Series Airtight and Series Airstop closed blade leakage 1000mm wide x 1000mm high Damper. Specification Energy/Shield All dampers can be factory fitted with one of the following controls; Type Q Manual quadrant control. (fitted as standard) Type E Belimo actuator either 24V or 240V open/closed 24V or 240V spring return or 24V modulating. Type X Extended shaft control. Type P Pneumatic actuator. synthetic trailing blade edge and side seals and blade end bearings. Housed in a galvanised steel frame having integral peripheral flanges, either prepunched elongated corner holes to suit proprietary duct flanges (Type FLA) or with galvanised spigotted adaptor plates for square, rectangular or flat oval duct connections (Type SPG) which shall provide with all welded corners a dust proof casing of high strength and rigidity. Blade widths greater than 1100mm having the blade stabiliser system fitted. The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. Energy/Shield Airstop as supplied by Actionair. 2000 1500 1200 1000 PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 500 300 250 200 150 120 100 Energy/Shield range of dampers are suitable for mounting in the vertical plane (with the blades running horizontally) and in the horizontal plane. 70 50 1 3 5 7 10 15 20 25 30 LEAKAGE (I/s) Table 3 Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. The information contained herein is subject to change without notice due to continuing research and development. Energy/Shield Airbalance air control and system balancing dampers comprising of 100mm extruded aluminium inner reinforced aerodynamic blades in mill finish with synthetic blade end bearings. Housed in a galvanised steel frame having integral peripheral flanges, either prepunched elongated corner holes to suit proprietary duct flanges (Type FLA) or with galvanised spigotted adaptor plates for square, rectangular or flat oval duct connections (Type SPG) which shall provide with all welded corners a dust proof casing of high strength and rigidity. Blade widths greater than 1100mm having the blade stabiliser system fitted. The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. Energy/Shield Airbalance as supplied by Actionair. Energy/Shield Airstop air control and system balancing and low closed blade leakage dampers comprising of 100mm extruded aluminium inner reinforced aerodynamic blades in mill finish with Energy/Shield Airtight air control and system balancing and low closed blade leakage dampers, comprising of 100mm reinforced stainless steel aerodynamic blades with synthetic blade edge and side seals and blade end bearings. Housed in a galvanised steel frame having integral peripheral flanges, either prepunched elongated corner holes to suit proprietary duct flanges (Type FLA) or with galvanised spigotted adaptor plates for square, rectangular or flat oval duct connections (Type SPG) which shall provide with all welded corners a dust proof casing of high strength and rigidity. Blade widths greater than 1250mm having the blade stabiliser system fitted. The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. Energy/Shield Airtight as supplied by Actionair. 7 Energy/Shield no compromise... Product Range Smoke/Shield PTCTM Automatic Smoke and Fire Dampers Vent/Shield PTCTM Automatic Smoke Release Dampers Hot/Shield PTCTM High Operating Temperature Automatic Smoke and Fire Dampers Hot/Shield Vent PTCTM High Operating Temperature Automatic Smoke Release Dampers Actionpac LNS Addressable Smoke and Fire Damper Control Systems Actionpac EM Electro Mechanical Smoke and Fire Damper Control Systems Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Trans/Shield Air Transfer Smoke and Fire Dampers Air/Shield System Air Balancing and Shut-off Dampers Energy/Shield Heavy Duty Air Control and Shut-off Dampers Standard Ordering Procedure Please Specify Quantity Series Type Control Options Number Required. Energy/Shield Airbalance, Energy/Shield Airstop or Energy/Shield Airtight. FLA-Flanged Casing or SPG-Spigotted Casing, in Rectangular, Circular or Flat Oval Configuration. Q E Manual Quadrant Control (always fitted as standard). Electrical Operator. 24V or 240V open/closed 24V or 240V spring return or 24V modulating. Extended Shaft Control. Pneumatic Control. . X P Duct Size Nominal Damper Size Example 2 / Energy/Shield Airstop Series / FLA / Q / 1000(W) x 800(H) Quantity Type Control Option Duct Size Flame/Shield Adjustable Coated Baffle Grease Filters Access/Shield Removable Hinged Insulated Access Doors Hydropac PHW 230 Horizontal Waterside Control Fan Coil Units Aeropac PHA 230 Horizontal Airside Control Fan Coil Units For further application, technical and pricing information, please refer to our Customer Service Office. S PREVEN T N IO CERTIFIC A ON TI NATIONAL ACCREDITATION OF CERTIFICATION BODIES Quality System Certificate No. 017 ­ Assessed to BS 5750 Part 2/ISO 9002/EN 29002 Hydropac PHW 170 Horizontal Slimline Waterside Control Fan Coil Units Hydropac PVW 230 Vertical Waterside Control Fan Coil Units BOARD L IM S LO Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk E IT D TH E");sQ1[33]=new Array("http://www.actionair.co.uk/pdf/fbseries1.pdf","FB Series.qxd","","October 2003 SERIES FB GALVANISED BLADED CURTAIN FIRE DAMPERS SPECIFICATION Galvanised steel bladed curtain fire dampers, having stainless steel constant tension closure springs with chain and bar type fusible link. Housed in a galvanised steel, spigotted type casing. Optional galvanised installation frames available. APPROVALS: BS 476 PART 20 1987, ( 4 HOURS). CONFORMS TO DW144 . Series FB Fire Dampers Product Details Casing Manufactured from 1.2mm (18swg) galvanised steel casings in accordance with HVCA ductwork specification DW144. Springs Stainless steel constant tension springs positioned out of the airstream to ensure positive closure of blades when the damper is installed either vertically or horizontally. Blades Roll formed interlocking blades manufactured from 0.7mm galvanised steel. Locking Ramp Manufactured from 1.6mm (16swg) galvanised steel. The locking ramp is designed to ensure the blade pack is closed off and remains locked in position until manually reset. Fusible Link The chain and and bar type link is supplied at a temperature rating of 72°C. Dimensional Data Basic Dampers Type FBL Blades partly in airstream. Square/Rectangular spigot connection. Vertical or horizontal mounting Dampers with Installation Frames OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 90 25 DUCT HEIGHT DUCT HEIGHT 25 DUCT WIDTH 100-1000 25 * USES SERIES FBL DAMPERS FOR DUCT HEIGHTS BELOW 250 100 - 1000 Type FBH Blades effectively outside airstream. Square/Rectangular spigot connection. Vertical or horizontal mounting DUCT HEIGHT 50 75 100 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 90 57 DUCT HEIGHT 25 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 90 38 78 38 25 25 * 250 - 624 625 - 850 851 - 1000 DUCT DIAMETER 25 DUCT DIAMETER 100-1000 25 DUCT DIAMETER Type FBC Blades effectively outside airstream. Circular spigot connection. Vertical or horizontal mounting Type FBO Flat Oval Dampers, (not illustrated) blade effectively outside airstream. Minimum size from 300 x 100 mm upto a maximum 1000 x 500mm. 25 50 75 100 57 57 100 - 249 250 - 624 625 - 850 851 - 1000 57 83 108 133 38 78 38 25 DUCT WIDTH 100-1000 60 80 60 Optional single pole change-over micro switch available. no compromise... Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited Quality System Certificate No 017 Assessed to ISO 9002 25 100 - 249 250 - 624 625 - 850 851 - 1000 * 250 - 624 625 - 850 851 - 1000 83 108 133 100 - 1000 57");sQ1[34]=new Array("http://www.actionair.co.uk/pdf/trans.pdf","trans.pdf","","August 2001 Trans/Shield Modes 1 & 2 Actionair Trans/Shield Modes 1&2 Transfer Stainless Steel Sliding Plate Fire and Smoke Dampers Features and Design Guide Slimline stainless steel sliding plate construction for air transfer applications through fire rated doors and dry/wall partitions. External manual release, resetting and testing facilities. External visual indication of damper status. Choice of two interchangeable and replaceable release and reset mechanisms with either manual (Mode 1) or manual and 24 Volt D.C. electro magnet release (Mode 2). Fail-Safe Fusible Link and spring instant closure. Five sizes available complete with specially designed matching non vision transfer grilles with radius edges and countersunk fixing. Dampers Designed and Built in Britain Trans/Shield Modes 1 & 2 Introduction The Trans/Shield Modes 1 and 2 stainless steels stainless steel sliding plate dampers are designed for air transfer applications through fire rated doors and dry wall partitions, providing up to 2 hour fire protection. Control Options A choice of two interchangeable and replaceable Release and Reset Mechanisms is available with either a Manual Release (Mode 1) or a Manual and 24 Volt D.C. Electro Magnet Release (Mode 2) being self contained in a compact Cassette with simple screw attachment direct to the Damper. For easy withdrawal without disturbance other than the removal of the relevant Transfer Grille. Removal of the Release and Reset Mechanism Cassette provides the further fail-safe feature of Damper instant closure which cannot be reversed until the proper replacement is made. External Manual Release, Resetting and Testing Facilities The Cassette also contains, recessed but readily accessible exter nally operated Release and a Resetting facility through the Transfer Grille. The Release Lever when manually depressed overrides all other functions to close the Trans/Shield Damper for periodic operational testing. The Resetting Shaft when manually tur ned in a partial anti-clockwise direction automatically resets the Trans/Shield Damper in the open position assuming all other functions are intact. The Range Flanged 18 gauge stainless steel Sliding Seal and Static Damper Plates with horizontal perforations which provide, whilst the Seal Plate is in the open position, a free area of not less than that of the specially designed Grilles, for the passage and transfer of ventilation air in either direction. The Damper Sliding Plate is retained to the Damper Static Plate with stainless steel shouldered rivets and fails-safe to the instant closed position, powered by two stainless steel tension springs, with the melting and parting at a temperature of 72 °C of an all brass Fusible Link attached to Sliding Seal Plate, to form a fire resistant shield from either air flow direction. The Fusible Link functions independently and regardless of choice or status of Release and Reset Mechanism. Control Mode 1 A fusible link actuates the instant closure of the damper due to an abnormal rise in temperature. Control Mode 2 The 24 Volt D.C. Electro Magnet is normally energised to hold open the Trans/Shield Damper, which will instantly close when the electrical supply is interrupted, either as a function of a smoke detection system or due to failure of the electrical supply and in both events, prior to the operation of the Fusible Link on temperature rise or a full fire condition. It is recommended that the continuous electrical supply (83mA Load) to the 24 Volt D.C. Electro Magnet is through a battery circuit and not an automatic change-over system. External Visual Indication of Damper Status The Trans/Shield Damper on closing, automatically disengages a spring loaded Damper Set and Status Pin, which is encapsulated with a distinct red plastic capping, providing visual indication of Damper status. Slimline Casing Both Damper Plates together with a choice of two interchangeable and replaceable Release and Reset Mechanisms with both being self contained in a removable Cassette, are housed within an 18 gauge stainless steel Slimline Damper Casing which has integral flanges with prepunched fixing and alignment holes for ease of installation. The Trans/Shield Damper complete with 18 gauge stainless steel flanged backing sleeve and matching Transfer Grilles can be readily accommodated in half-hour fire rated 44mm thick and 1 hour fire rated 54mm thick doors as well as fire rated dry wall/partitions. Matched Transfer Grilles A pair of specially designed matching non vision Transfer Grilles with radius edges and countersunk fixing holes are always supplied with each Trans/Shield Damper for fitting to both sides of door or dry wall/partition. The Transfer Grilles are constructed in 18 gauge galvanised mild steel finished in Polyester Powder coat to RAL 8025 gloss brown, as standard. As an optional additional cost, the grilles can be finished in either BS or RAL standard colours. 2 Trans/Shield Modes 1 & 2 Installation procedure 1. Make the the structural opening to the actual dimensions of the Cutting Hole Size of the selected Damper. 2. Locate the Flanged Backing Sleeve with the 8mm flange height at the top into whichever side is deemed to be the rear of the structural opening and when uniformally spaced therein use as template to mark position of all flanged 4mm diameter screw holes. 3. The Flanged Backing Sleeve can then be removed and all pilot holes drilled accordingly. 4. Relocate the Flanged backing Sleeve at the same time providing an application of the fire resistant sealant between the back of the flange and the structural opening periphery, before screw fixing with the slotted head screws provided to the structure face using all the countersunk flange holes only, as the remaining four side plain holes are for alignment with and fixing through to the structure, of the rear Transfer Grille complete with non vision baffle. Flanged backing Sleeve TOP THE 4 PLAIN HOLES ARE FOR TRANSFER GRILLE ALIGNMENT AND FIXING COUNTERSUNK HOLES ARE FOR FIXING TO STRUCTURAL FACE AND THE NUMBER VARY DEPENDENT ON DAMPER SIZE 6. The Damper Assembly can then be removed and all pilot holes drilled accordingly. 7. Relocate the Damper Assembly and if the Damper is fitted with Mode 2, ensure that the electrical power supply is isolated and the wiring is then continued through the appropriate side hole of the Damper Assembly before applying the necessary fire resistant and screw fixing with the slotted head screws provided to the structure face in the same manner as described for the Flanged Backing Sleeve in (4) above. Damper Assembly TOP THE 4 PLAIN HOLES ARE FOR TRANSFER GRILLE ALIGNMENT AND FIXING COUNTERSUNK HOLES ARE FOR FIXING TO STRUCTURAL FACE AND THE NUMBER VARY DEPENDENT ON DAMPER SIZE Damper status. 11. Once satisfied with the operational testing of the damper, complete the installation by aligning the side countersunk holes to the rear and front transfer Grilles with the corresponding side holes in the two non vision baffles (should they have separated from the Grille) and the remaining side flange holes of the Flanged backing Sleeve and the Damper Assembly respectively. Screw fix with the pozi-driv screws provided, to either side of the structural opening, ensuring that the 45mm flange height on the rear Transfer Grille is at the top and that the three holes in the centre of the 45mm flange height of top of the front Transfer Grille are in line with and provide access to the functional aspects of the Damper Cassette Transfer Grilles FRONT ELEVATION PLAN VIEW FIXED TO FRONT OF STRUCTURAL OPENING ALTERNATIVE ELECTRICAL SUPPLY ENTRY POINTS FOR DAMPERS FITTED WITH MODE 2 FRONT GRILLE FIRE RESISTANCE SEALANT BETWEEN BACK OF FLANGE AND STRUCTURAL OPENING PERIPHERY SIDE ELEVATION IN STRUCTURAL OPENING FRONT ELEVATION PLAN VIEW FIXED TO REAR OF STRUCTURAL OPENING FIRE RESISTANCE SEALANT BETWEEN BACK OF FLANGE AND STRUCTURAL OPENING PERIPHERY 5. Locate the Damper Assembly with the Cassette at the top into the opposite front side of the structural opening and inside the Flanged backing Sleeve and when uniformally spaced therein use as template to mark position of all flanged 4mm diameter screw holes, and note that the two holes in line with the Cassette at each end of both sides of the Damper Assembly are alternative electrical supply entry points for Dampers fitted with Mode 2. 8. If the Damper is fitted with Mode 2 connect the electrical supply wiring to the Cassette terminal block. 9. Set the damper in the open position by engaging 4mm hexagon allen key in the Cassette Resetting Shaft and turning same in a partial anti-clockwise direction when the Damper should remain in the open position, unless, in the case of Mode 2 operation there is no electrical power supply to the 24 VOLT D.C. Electro Magnet, in which event the Damper will immediately failsafe closed. 10. Release the Damper to the closed position by also using 4mm hexagon allen key to manually depress the Cassette release Lever and closing the Damper disengages within the Cassette a spring load Damper Set & Status Pin, the end of which is encapsulated with a distinctive red coloured plastic capping and with an outward movement to a completely exposed position on the Cassette front face provides visual indication of REAR GRILLE Cassette Interchangeability or Replacement 1. Un-screw the four pozi-driv fixing screws of the front Transfer Grille and remove same together with the non vision baffle to expose the Cassette. 2. If the Damper is fitted with Mode 2 isolate the electrical power supply before disconnecting the wiring from the Cassette terminal block. 3. The Cassette has simple two screw attachment direct to the Damper Static Plate within the Damper Assembly and unscrewing the two slotted head screws enables the Cassette to be withdrawn outward from the Damper Assembly. 4. Cassette interchangeability or replacement is achieved through reversing all the foregoing procedure 3 FRONT REAR Trans/Shield Modes 1 & 2 Control Mode 2 Electrical Wiring with optional microswitch and optional 1 metre 5 core cable ORANGE 24 VOLT A.C. SUPPLY BROWN CABLE PART NO. SM060 RATED 60 VOLTS A.C. 1 AMP PER CORE ORANGE BROWN 24 VOLT D.C. ELECTROMAGNET COMMON NORMALLY OPEN NORMALLY CLOSED RED BLACK YELLOW (CUSTOMER MUST PROTECT AND RETAIN CABLE AT POINT OF ENTRY TO THE TRANS/SHIELD DAMPER) RED BLACK YELLOW RED 15MM CABLE BLACK 15MM CABLE YELLOW 15MM CABLE (OPTIONAL EXTRA) Dimensional Data 1. Dampers are suitable for vertical application only, with the passage and transfer of ventilation air in either direction. 2. Dampers are supplied with the Sliding Seal Plate in the closed position to prevent damage in transit and the ingress of building dust and dirt on site and during installation; and it is recommended that the Sliding Seal Plate should remain closed until the actual date of commissioning. 3. Flanged Backing Sleeves have a sleeve depth of 40mm, a top flange height of 8mm, sides and bottom flange heights of 20mm, and are supplied 5mm, under the cutting hole size. 4. Damper Assemblies have a depth of 42mm, a top flange height of 8mm, sides and bottom flange heights of 20mm, and are supplied 5mm, under the Flanged Backing Sleeve size for always fitting within the Sleeve. 5. The Cassette regardless of choice of Mode is 140mm wide x 35mm high x 26mm deep. 6. Transfer Grilles have a top flange height of 45mm, with sides and bottom flange heights of 25mm. 7. To order specify Trans/Shield Cutting Hole Size and Mode Number. 8. Trans/Shield Dampers are an Actionair Quality Engineered Life Safety product and should always be fitted and operated in accordance with instructions provided. RESET STATUS RELEASE Size 160 x160 RESET STATUS RELEASE Size 310 x 160 RESET STATUS RELEASE Size 310 x 300 RESET STATUS RELEASE Size 450 x 300 Cutting Hole Size WxH 160 x 160 310 x 160 310 x 300 450 x 300 450 x 430 Grille O/A Size WxH 195 x 190 345 x 190 345 x 330 485 x 330 485 x 460 Effective Damper Grilles Only Free Area (Including Grilles) (Per Pair) m2 Approx Approx Weight Kg Weight Kg 0.007 0.014 0.028 0.042 0.063 3.0 4.0 6.0 8.0 11.0 1.0 2.0 3.0 4.0 6.0 RESET STATUS RELEASE Size 450 x 430 4 Trans/Shield Modes 1 & 2 Non Door Applications Suggested builder's work detail for fitting Trans/Shield Damper in blockwork wall DRILL HOLE FOR CABLE WHEN FITTING TRANS/SHIELD MODE 2 DAMPER TRANS/SHIELD GRILLE MUST OVERLAP APERTURE-HARDWOOD STRIPS TO MAINTAIN FIRE BARRIER INTEGRITY A HARDWOOD STRIPS FIXED INTO WALL OPENING C Trans/shield Mode 1 and 2 Damper B 40 MIN SIDE ELEVATION FLANGED BACKING SLEEVE &quot;X&quot; 40 42 14 MODE 1 OR MODE 2 CASSETTE 8 PLAN 40 MIN 32 8 GRILLE 8 mm Dia. HOLE FOR MODE 2 CABLE ENTRY FLANGED DAMPER SLEEVE (INCLUDING DAMPER) Nominal Size A 160 x 160 310 x 160 310 x 300 450 x 300 450 x 430 190 340 340 480 480 B 160 310 310 450 450 C 160 160 20 20 GRILLE 300 300 430 All dimensions are in millimetres. SPECIAL EXTENDED WALL SLEEVE OF 18 GAUGE STAINLESS STEEL FACTORY FITTED TO STANDARD TRANS/SHIELD FLANGED DAMPER SLEEVE Trans/shield Mode 1 and 2 Damper complete with Extended Wall Sleeve Extended Wall Sleeve Standard units are suitable for thickness 44mm to 80mm. Wall sleeves are required for greater thickness. With this sleeve arrangement, Dimension &quot;X&quot; can vary according to wall thickness, from 81mm up to a maximum of 300mm. Please advise Dimension &quot;X&quot;. The information contained herein is subject to change without notice due to continuing research and development 5 Trans/Shield Modes 1 & 2 Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of Trans/Shield Stainless Steel Sliding Plate Fire and Smoke Dampers complete with matching non vision Transfer Grilles. A programme of extensive tests was carried out in the Reverberation Room of Sound Research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos. 2750, 4196, ISO. 140 and 3741 Part 1. This independent test facility is approved under the NAMAS Scheme. Selection and Acoustic Performance W ith a known air volume select a suitable size of Trans/Shield Damper and a resultant pressure drop can be determined and the sum of these two components applied to the Volume X Pressure Drop Vs Sound Power Level Graph. This graph is the result of a full range of acoustic tests on the Trans/Shield Damper complete with matching Transfer Grilles. The Spectrum Correction Data is applied to the number obtained from the graph and a full Sound Spectrum of Flow Generated Noise (outlet) is obtained. Example: W ith an air transfer air volume requirement of 60 I/s and selecting Size 310 x 300 Trans/Shield Damper and Grilles. Pressure Drop = 14 Pa. Multiply Volume X Pressure Drop 60 x 14 = 840. From the Graph Sound Power Level dBW = 43 less Spectrum Corrections. From the Pressure Drop Vs Velocity Graph the selected Size 310 x 300 Trans/Shield Damper and Grilles at a pressure drop of 14 Pa produces a velocity of 2.1 m/s. 43 0 E4 50 x3 SIZ 00 E3 10 x3 00 SIZ E3 10 x1 60 SIZ E1 60 x1 60 SIZ Pressure Drop Vs Velocity 100 90 80 70 60 50 40 30 20 PRESSURE DROP Pa 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 SIZ E4 50 x VELOCITY m/s Air Volume Vs Pressure Drop 100 90 80 70 60 50 40 30 Air Volume (l/s) x Pressure Drop (Pa) Vs Sound Power Level (dBW) 70 60 SOUND POWER LEVEL (dBW) PRESSURE DROP Pa SIZ E1 60 x1 SIZ 60 E3 10 x1 60 SIZ E3 10 SIZ x3 E4 00 SIZ 50 E 4 x 30 50 0 x4 30 20 50 10 9 8 7 6 5 4 3 2 40 30 20 1 50 60 70 80 90 100 200 10 20 30 40 10 4000 5000 6000 7000 8000 9000 10000 400 500 600 700 800 900 1000 2000 3000 50 60 70 80 90 100 200 300 10 20 30 40 AIR VOLUME I/s AIR VOLUME X PRESSURE DROP (I/s Pa) Outlet (in duct) Spectrum Correction Octave band 63 125 250 500 OPEN 11 3 7 8 1K 12 2K 15 4K 21 8K 28 Hz dB 6 Trans/Shield Modes 1 & 2 Specification The design of the Trans/Shield Dampers shall comprise of flanged 18 gauge stainless steel Sliding Seal and Static Damper Plates with horizontal perforations to provide whilst the Seal Plate is in the open position, a free area of not less than that of the matching Transfer Grilles, for the passage and transfer of ventilation air in either direction. The Damper Sliding Seal Plate shall be retained to the Static Damper Plate with stainless steel shouldered rivets and fail-safe to the instant closed position powered by two stainless steel tension springs either by the melting and parting of an attached Fusible Link at a temperature of 72 °C, or the functioning of the relevant Release and Reset Mechanism to maintain integrity and not permit the passage of flame when exposed to the time/temperature curve of BS476 Part: 20 1987 for a period of two hours as tested by the Fire Insurers' Research & Testing Organisation (Approval TE 6523). Both Damper Plates together with a removable Release and Reset Mechanism Cassette shall be housed within an 18 gauge stainless steel slimline Damper Casing having integral flanges with prepunched fixing holes. The Cassette shall have screw fixing for ease of attachment to and withdrawal from the Damper Static Plate without disturbance to the Damper and shall contain recessed from view but readily accessible, a Release Lever and Resetting Shaft, both manually operated, and a spring loaded Damper Set and Status Pin which in the exposed position shall provide visual indication of Damper status. The Cassette shall also contain either of two interchangeable and replaceable Release and Reset Mechanisms. Mode 1 Manual Release Fusible Link shall actuate the instant closure of the Damper due to an abnormal rise in temperature. Mode 2 Manual and Electro Magnet Release Customer Service A 24 Volt D.C. Electro Magnet shall actuate the instant closure of the Damper when the electrical supply is interrupted, either as a function of a Smoke Detector System or due to failure of the electrical supply and in both events, before the operation of the Fusible Link due to an abnormal rise in temperature or a full fire condition occurs. Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. Each Trans/Shield Damper shall be complete with 18 gauge stainless steel flanged backing sleeve and a pair of specially designed matching non vision Transfer Grilles with radius edges, countersunk fixing holes and constructed in 18 gauge galvanised mild steel finished in Polyester Powder coat to RAL 8025 gloss brown. The Trans/Shield Dampers and Transfer Grilles suitable for mounting in the vertical plane only, shall be manufactured by Actionair. Approvals Product Conformity awarded by The Loss Prevention Certification Board Limited. Fire tested (2 hour rating) Fire Insurers Research and Testing Organisation. The information contained herein is subject to change without notice due to continuing research and development. 7 Trans/Shield Modes 1 & 2 no compromise... Standard Ordering Procedure Please Specify Quantity Series Control Mode Cutting Hole Size Accessories Extended Wall sleeve Special Grille Finish (Options) Volt Free Contact for Status Indication (Single Pole Micro Switch) Customer to provide dimension x, please refer to page 5. 1. Special paint finishes ­ specify BS or RAL number and gloss or matt finish. 2. Unpainted galvanised steel grilles. Volt Free Contact for open or closed status indication. Connection strip on left hand side (when viewing grille front elevation). Number Required. Trans/Shield. Mode 1 Fail-Safe Fusible Link. Mode 2 24 Volt D.C. Electro Magnet and Fail-Safe Fusible Link. Sizes 160 x 160, 310 x 160, 310 x 300, 450 x 300, 450 x 430, (W) x (H) mm. Example 7 Quantity / Trans/Shield Series / M2 Control Mode / 310 x 300 Cutting Hole Size / Extended Sleeve `x' = ? Accessories For further application, technical and pricing information, please refer to our Customer Service Office. Quality System Certificate No 017 Assessed to ISO 9002 BS EN ISO 9002 : 1994 Certificate No. FM1611 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[35]=new Array("http://www.actionair.co.uk/pdf/transacs.pdf","Trans Shield ACS.qxd","","February 2003 Trans/Shield ACS Actionair Trans/ Shield ACS Fully Automated Intumescent Fire and Sliding Plate Smoke Damper Features and Design Guide Slimline non-vision intumescent fire and smoke damper with unique sliding plate smoke control. Fully automatic open/close operation with Talkpac 2-way communication smoke control system. Continuous status monitoring and display. Fail-safe closure for smoke control operation. Self testing on a 24 hour programme. Automatic reset to open position when alarm cancelled or power restored. Low voltage D.C. supply to dampers. Up to 16 dampers controlled from one Talkpac panel with simple loop wiring. Complies to electro magnetic compatibility and low voltage directives. 1 hour fire rating door mounted. 2 hour fire rating wall mounted. Dampers Designed and Built in Britain Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Introduction The Trans/Shield ACS fully automated intumescent fire and sliding plate smoke dampers are designed for air transfer applications through fire rated doors and walls. The range of combined intumescent fire and smoke dampers can be used in all applications where cold smoke containment is required. These dampers are connected, via a control p a n e l , to a standard fire alarm s y s t e m . In event of an alarm c o n d i t i o n , or power failure, the d a m p e r s shut, preventing the p a s s a g e of cold smoke. These p ro d u c t s have been designed to a l l o w the smoke damper element t o be used without the intumescent, in applications where only smoke and/or gas containment is required. Air transfer products have many applications in new building and refurbishment projects. Ventilation through doors and walls is often a very cost effective means of improving air quality by better air distribution. However, the use of straight forward air transfer grilles often conflicts with the needs of fire safety, particularly where ventilation is required between fire compartments or into corridors and other `means of escape' routes. The Trans/Shield ACS-D door mounted damper/air transfer products have been tested in door assemblies under the conditions of BS 476 Pt 22 to determine fire performance, and BS 476 Pt 31.1 to established smoke leakage criteria. It is worth noting that a fire door illegally jammed open to allow air movement, or a fire door which cannot be opened or closed properly due to differential air pressure, is potentially a major hazard. Ventilation engineers have found the flexibility of the design that the automatic fire and smoke dampers provide, contribute to versatile installations which meet the demands 2 of good air quality and fire safety requirements. Computer rooms and communications centres are often protected from the spread of fire by the use of halon substitute gases. The nature of these environments demand good air movement but, in the event of a fire, the containment of the fire suppressant gases is imperative. Once the fire is out, it is also important to be able to automatically ventilate the enclosure to allow the earliest human occupancy. The Trans/Shield ACS fire and smoke damper/air transfer grilles will satisfy these needs entirely. The Range Fire resistant air transfer grilles for a range of applications and fire performance levels are available in the form of intumescent damper/air transfer grilles. These products react to temperatures in excess of 100 °C, whereupon the swelling of the intumescent material seals the entire aperture area. This system, whilst very effectively preventing the spread of fire through air transfer apertures in fire doors, walls or ducts, does not control the movement of cold smoke or fire extinguishing gases. To satisfy this requirement the Trans/Shield ACS will, when combined with intumescent damper/air transfer grilles, provide complete fire and smoke protection. The smoke control systems are intended to be interfaced with a fire alarm panel via the Talkpac panel. It is possible to connect the Talkpac panel direct to `stand alone' smoke sensors without an interface with the building alarm panel. This should only be undertaken after consultation with the Fire Authorities and the Actionair Sales Office. The Trans/Shield ACS smoke control system satisfies the need offering up to sixteen dampers per control panel with full status monitoring and automatic cycling facilities. Special control systems can be supplied to suit specific customer installation needs. All relevant components in the smoke control systems have been tested to the appropriate standards in conformance with Electro Magnetic Compatibility and Low Voltage Directives. Talkpac Control System Most large public buildings, high rise offices, hospitals and hotels require a significant number of FD30S and FD60S fire doors (30 minute or 60 minute fire doors with smoke leakage constraints), within any one fire zone. These doors may spread over a considerable distance and may even be at different floor levels, and may have to provide air transfer. Additional air transfer may be required through wall apertures or duct openings. The Talkpac system has been designed to provide up to 16 damper/air grille locations with one centralised status monitoring location. The unique 2-way communication system between the Talkpac panel and the damper actuators facilitates rapid assessment of the installation and immediately identifies the location of a defective damper. Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Features Fail-Safe Designed to close automatically in the event of a fire alarm being activated, a power failure or wiring damage. Auto Reset Will reset automatically to the open position when the fire alarm is cancelled or power restored. Autocycling Once in every twenty four hours each damper is closed and re-opened to prevent a build up of dust or debris between moving parts. Loop Wiring Up to 16 dampers can be connected via a 3-core cable which can be arranged in a ring. The wires from the Talkpac panel to the dampers carry only safe low D.C. voltages. (Refer to page 9 for wiring details). Continuous Monitoring Trans/Shield ACS dampers/air transfer grilles are monitored continuously by the Talkpac panel which identifies the status of each individual damper through its uniquely ­ addressed chip. Positive Closing Energy stored within a capacitor on each damper actuator is used to power the electric motor to the closed position in the event of a fire alarm being activated. Solid State Solid state microchip technology is employed to provide versatility and reliability. Assembled Tested Each damper is assembled and fully tested, therefore requiring no adjustment on site, facilitating simple installation. Standard sizes available (mm) 200mm wide x 200mm square unit 300mm wide x 300mm square unit 450mm wide x 450mm square unit. Effective 0.012 m2 0.027 m2 0.061 m2 Free Area 200mm x 200mm 300mm x 300mm 450mm x 450mm. Trans/Shield ACS-D Door Mounted Trans/Shield ACS-W Wall Mounted Compatibility The Talkpac system is designed to interface with any fire alarm panel and subsequent to initial installation, additional dampers can be incorporated where there are free channels in the system. C E Marking Successfully tested in accordance with the requirements of Electro Magnetic Compatibility and Low Voltage Directive, and therefore bears the CE mark. 1 hour fire rating Door mounted 2 hour fire rating Wall mounted. 3 Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Trans/Shield ACS-D Door Mounted Non-Vision Fire and Smoke Containment Damper Trans/Shield ACS-D is a non-vision style fire and smoke damper designed to fit into a door (minimum 44mm thickness). They come complete as a factory tested product with decorative flanges to suit. These products require no cover grilles as the slat components are angled to ensure visual privacy and are finished in white. Operation of the smoke damper would be through the Talkpac control panel. Up to 60 minutes fire resistance can be achieved with this product. Orientation These products are designed to be installed in a vertical orientation as shown. Standard Sizes Available (mm) 200mm wide x 200mm high 300mm wide x 300mm high 450mm wide x 450mm high. Intumescent Damper / air grille Fixed plates Sliding plate Integral flange Intumescent liner Actuator Damper Fitting Instructions (ACS-D) Ensure that cutting an aperture in the door will not detract from the fire integrity of the door. Contact the manufacturer to establish the maximum size and optimum position. The initial installation of this type of damper is best carried out with the door dismounted. If rebated threshold seal is to be fitted this should be done temporarily before fitting the damper assembly and then removed. Trans/Shield ACS dampers are supplied 2mm less than the nominal size e.g. a 300mm x 300mm is actually 298mm x 298mm. The flange requires a minimum of 6mm extra clearance overall. e.g. overall dimension of a nominal 300mm x 300mm damper will be 304mm x 304mm. Overall flange dimension 348mm x 348mm. Cut the aperture to the required size with a maximum gap all around the outside of the flange of 3mm. Check that the two halves of the damper fit into the aperture without twisting, jamming, or in any way distorting. Then remove them from aperture. Drill vertical outer frames of each damper and flange sub assembly to accept fixing screws. 4 Drill and rebate door to provide wiring route to conductor hinges or loop connection. Fit intumescent inserts to the inside faces of the aperture. Fit the damper sub assembly that incorporates the actuator into the aperture, ensuring that the actuator is at the bottom of the aperture. Route the wiring into the required connection (hinge or loop) ensuring that it lies tidily and does not cause any distortion of the damper, or is likely to become trapped. Fit retaining wood screws through pre-drilled holes in damper vertical outer uprights into door. Refer to wiring instructions. Carry out a function check of the damper by activation from the Talkpac panel whilst actuator is visible and wiring accessible, before fitting the remaining half of the damper. After satisfactorily completing function check, fit the remaining half of the damper assembly ensuring that the smoke control sliding plates do not become squeezed between the two damper halves or wiring becomes trapped. Repeat the function check on complete installation. Fire door Mounting flange Damper to door fasteners 25mm wood screws AIRFLOW Horizontal intumescent louvred slats Hit and miss smoke control plates Centre plate moves. Outer plates fixed Trans/Shield ACS-D Damper Intumescent inser ts between the damper and the door This dimension should be no less than 100mm. Consult door manufacturer before cutting out Automatic threshold seal Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Performance Criteria The acoustic and aerodynamic performance is based on a door mounted application with a Trans/Shield ACS-D fire and smoke rated intumescent damper. NOMINAL WIDTH (mm) NOMINAL HEIGHT (mm) 1000 900 800 700 600 500 400 100 POINT LINE AIR FLOW RATE (I/s) 100 150 150 300 SOUND POWER LEVEL LWA(dB) 200 60 200 200 250 100 300 200 50 250 50 350 40 300 10 400 450 30 350 100 400 TOTAL PRESSURE LOSS 450 Pt (Pa) 50 40 30 20 Example Determine the total pressure drop Pt (Pa) and the radiated sound power level LWA (dB) for a Trans/Shield ACS-D 200 x 200mm damper for a volume flow rate of 60 (l/s). On the chart, draw a straight line from 200 on the nominal width axis to 200 on the nominal height axis. At the intersection point with the pivot line, draw a line to 60 (I/s) on the flow rate axis. The radiated sound power LWA (dB) and total pressure drop Pt (Pa) may now be read directly. Type: Trans/Shield ACS-D 200 x 200mm Flow rate(I/s): 60 Total pressure drop (Pa): 42 Radiated sound power LWA (dB): 45 5 Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Trans/Shield ACS-W Wall Mounted Non-Vision Fire and Smoke Containment Damper Wall mounted fire and smoke dampers are supplied as factory tested units complete with steel cover grilles. The non combustible housing containing the shutter plate system and intumescent damper is manufactured to the depth of the wall (minimum 100mm) allowing simple and quick installations on site. Up to 120 minutes fire resistance can be achieved with this product. Operation is through a Talkpac control panel. Key Features 120 minutes fire resistance Containment of cold smoke Supplied as a tested assembly Simple installation Auto reset and failsafe Safe low D.C. voltage Status reporting and autocycling Optional audible warning facility No current used when open or closed Bi-directional airflow. Damper Fitting Instructions (ACS-W) The damper is supplied ready assembled in a mineral board casing. Care must be taken not to damage the casing during installation. Cut the aperture to the required size with a maximum gap all around of 5mm. If the resulting aperture is out of square, irregular or over sized, make good with mortar. Remove cover grilles. Drill the casing for wall fixing screws, a minimum of 4 holes will be required. Trial fit the damper assembly into the aperture and ensure that it can be positioned within the section of the wall, without jamming or twisting. Position the damper assembly so that one face is flush with one face of the wall. Mark around the damper casing at the opposite face to determine the amount needed to be removed to give a flush fit on both faces. Also mark the positions of the wall fixing screws through the holes drilled. Establish the actuator cable run and make the necessary cut outs to suit. Remove the damper assembly from the wall aperture. Trim the damper casing to the marked length.Drill the wall for screw plugs and fit plugs. Apply intumescent mastic to aperture faces. Position damper assembly square and flush to both faces of the wall while feeding the actuator cable into the selected position. Fit casing fixing screws to the wall. Bed in mastic around damper casing. Clean off surplus mastic and ensure outer edge of damper casing is fully sealed. Fix actuator cable to casing with small cable clips to prevent it fouling the shutter plates. See wiring instructions. Carry out function check of the damper by activation from the Talkpac panel. After satisfactorily completing the function test, position a pressed steel cover grille concentrically over one face of the damper and fix using screws into wall plugs.Repeat with other grille. Overall grille dimensions are nominal size plus 44mm. Smoke shutter module Intumescent mastic to bed casing into wall Cover grille fixing screws into wall plugs Brick, block or masonary wall Mortar facing over irregular surfaces Mineral board facing Pressed steel cover grille Trans/Shield ACS-W damper Damper casing fixing screw Actuator cable General The Trans/Shield ACS damper is designed to be linked with smoke sensors via a fire alarm panel and therefore provide excellent hot and cold smoke containment. The combination of intumescent and electro-mechanical technologies allows proven fire resistance with very good insulation properties. Remarkably little current is used by the servo motor when opening or closing the smoke shutter module and none is drawn when the shutter plates are either closed or open. The units can be supplied to suit a range of wall thickness and aperture sizes. Pressed steel cover grilles are supplied in a white finish. Specifications Materials The damper casing is manufactured from high grade mineral board and is supplied complete with the fire damper and smoke shutter fully assembled. Orientation These products are designed to be installed in a vertical orientation as shown above. Non-combustible housing Fixed plates Intumescent damper/ air transfer grille Sliding plate Actuator Steel cover grille Intumescent liner Standard sizes available (mm) 200mm wide x 200mm high 300mm wide x 300mm high 450mm wide x 450mm high. Depths available 100,150,200,225,250 and 300mm. AIRFLOW 6 Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Performance Criteria The acoustic and aerodynamic performance is based on a wall mounted application with a Trans/Shield ACS-W fire and smoke rated intumescent damper fitted with cover grilles. NOMINAL WIDTH (mm) NOMINAL HEIGHT (mm) 1000 900 800 700 600 500 400 SOUND POWER LEVEL LWA(dB) 100 POINT LINE AIR FLOW RATE (I/s) 100 150 150 300 200 200 60 200 50 100 50 300 40 10 100 30 5 400 450 TOTAL PRESSURE LOSS Pt (Pa) 50 600 40 600 500 550 400 450 500 550 350 350 300 250 250 30 20 Example Determine the total pressure drop Pt (Pa) and the radiated sound power level LWA (dB) for a Trans/Shield ACS-W 200 x 200mm damper for a volume flow rate of 60 (l/s). On the chart, draw a straight line from 200 on the nominal width axis to 200 on the nominal height axis. At the intersection point with the pivot line, draw a line to 60 (I/s) on the flow rate axis. The radiated sound power LWA (dB) and total pressure drop Pt (Pa) may now be read directly. Type: Trans/Shield ACS-W 200 x 200mm Flow rate(I/s): 60 Total pressure drop (Pa): 23 Radiated sound power LWA (dB): 34 7 Trans/Shield ACS Talkpac Damper Control System Talkpac Damper Control System Application The Talkpac system has been designed to provide monitoring and control of up to 16 damper/air grilles from a single centralised status monitoring location. The unique 2way communication system between the Talkpac panel and the damper actuators facilitates rapid assessment of the installation and immediately identifies the location of a defective damper. The Talkpac system comprises of the panel and up to 16 uniquely addressed damper assemblies. The interconnecting 3-core cable can be installed as a loop for greater reliability and maximum range, or it may be spurred if necessary. An audible warning device can also be connected to the panel as an optional extra. This device would be incorporated to draw attention to the panel's status display in the event of a fault occurring. The panel incorporates connection for battery back-up but there is insufficient space to accommodate a rechargeable battery within the enclosure. An appropriate battery and enclosure is available from Actionair if required. Talkpac panel This unit provides D.C. power, and monitors the status of dampers whilst interfacing with the fire alarm. The enclosure measures 175mm (w) x 160mm (h) x 130mm (d) overall, and incorporates a clear vision panel in the upper section. It should not be necessary to open this hinged panel during installation or in service. Access for wiring connections is through a screw fixed panel in the lower section of the enclosure. Reference to the wiring diagram will provide information concerning the relevant connections. The display panel contains three horizontal rows of light emitting diodes (LED). The top row of green LED's when lit indicates the dampers are open as per command. The bottom row of greens LED's indicates during a test cycle that the dampers are closed as commanded. The middle row of red LED's indicates a fault or an unconnected channel. Therefore, each vertical group of three LED's (i.e. Green, red and green) gives the status of the corresponding damper, i.e. open, fault, closed. There are two methods of interfacing the panel with a fire alarm panel:A. A signal generated by the Talkpac panel from the terminals marked (see page 11) can be passed through a normally closed volt free contact on the alarm panel. Or B. If the alarm panel has a spare 24 volt D.C. signal output which is normally live but ceases in the event of an alarm, this output can be wired to the FA (Aux) terminals in the panel (see page 11). During initial `powering up' a transformer and full wave rectifier within the panel converts a 230 volt A.C. supply to a clean 12.8 volt D.C. output. Initially an alarm condition is indicated until the system has stabilised. Each damper actuator in turn is then instructed to open according to the damper address. It will take approximately 10 seconds to cycle through all 16 channels. Each damper that has successfully closed will send confirmation back to the panel within 20 seconds of receiving instructions. The confirmation signal will ensure the top green LED remains illuminated. Should the damper not open fully, no confirmation signal will be received by the panel, consequently the top green LED will be extinguished and a red LED will illuminate, indicating a fault on that specific damper. Thereafter, an interrogatory signal is passed from the panel every 10 seconds to each damper actuator. The damper actuator in turn signals the panel that it is conforming with the instructions or a fault is assumed. Therefore, the panel is able to provide a continuous status update. Similarly, in a simulated situation or real alarm situation each damper actuator will be instructed to close which will illuminate the appropriate green LED's on the bottom row. Should the green LED be extinguished after 10 seconds and the middle row red LED then lights, a failure to fully close is indicated or no damper is connected to the channel. If at any time an actuator does not receive a signal from the panel within 10 seconds a fault or alarm is assumed and the actuator will close the damper in accordance with the `Fail Safe' imperative. A simulated alarm can be conducted manually during commissioning or for service testing by competent authorised personnel. For this purpose a rotary test switch is incorporated within the panel in the position as shown on diagram `C' (page 11). This switch should be operated with a small non-metallic screwdriver. Note Simulated alarm conditions can be created at any time, but they are automatically conducted every 24 hours during the auto-cycle. Wiring Information Each damper within a system has an individual code; therefore a 3-core cable is employed in order to provide a means of supply and signalling to each unique address. Using 1mm2 wire provides a ring system of a maximum circumference of 100 metres. If installed radially or spurred, the maximum length is 50 metres. These cable runs can be extended by increasing the wire cross sectional area. Where door mounted dampers are required, power and signal from the panel can be introduced to the door leaf by means of a specifically designed multi-wired conductor hinge. Therefore, the wiring can be completely concealed and is less vulnerable to tampering. Please refer to the wiring diagrams and the fitting instructions before attempting installation. 8 Trans/Shield ACS Talkpac Damper Control System Talkpac Damper Control System Schematic Wiring Installations Diagram A Ringed Wiring Installation. Actionair Trans/Shield ACS Talkpac Damper Control Panel Fire Alarm Panel Volt Free Contact (Normally Closed) Option A Optional Audible Alarm Optional Battery Back Up Fire Alarm Panel - 24V DC Signal Option B 230V A.C. Supply Damper 1 Damper 3 Damper 5 Damper 7 Damper 9 Damper 11 Damper 13 Damper 15 Damper 2 Damper 4 Damper 6 Damper 8 Damper 10 Damper 12 Damper 14 Damper 16 Diagram B Spurred Wiring Installation. Actionair Trans/Shield ACS Talkpac Damper Control Panel Fire Alarm Panel Volt Free Contact (Normally Closed) Option A Optional Battery Back Up Fire Alarm Panel - 24V DC Signal Option B 230V A.C. Supply Optional Audible Alarm Damper 1 Damper 2 9 Trans/Shield ACS Talkpac Damper Control System Talkpac Damper Control System Schematic Wiring Installations Diagram C Connections within Talkpac Damper Control Panel Optional Batter y Back Up Mains Supply 230V A.C. Supply and Signal to Dampers 12.8V D.C. Supply and Signal to Dampers 12.8V D.C. + ­ L N + ­ S + ­ S The function of the actuator is to open the damper/shutter in accordance with the alarm status as interpreted by the panel. The actuator employs a geared electric motor which provides a powerful action but with minimal current consumption, typically 5 milliamps when the damper is in the open position and 200 milliamps momentarily when in the process of opening. In the event of power failure, energy stored within the capacitor mounted on a printed circuit board (PCB) within the actuator unit is tapped to drive the motor to the closed position. In the event of an alarm the panel instructs the actuator to close which is executed by using the power supply from the panel. A Phototransistor is used to confirm the final position of the damper and initiates a signal to the panel, which illuminates a green LED on the bottom row of the display. This indicates that the damper is completely closed. If no signal is 10 received from the actuator by the panel within 10 seconds, a fault is assumed and a middle row red LED is illuminated. Cancellation of the alarm or restoration of power will trigger the panel to signal the actuator to move the damper to the open position, the final position of the damper being sensed by another photo transistor and reported to the panel for display. Should the actuator not receive a signal from the panel within a 10 second period, it will assume failure and close the damper. CE Marking EMC & LVD (Electro Magnetic Compatibility and Low Voltage Directive). Actionair smoke control systems have been successfully tested in accordance with the requirements of EMC & LVD and, therefore, bears the CE Mark (Conformite European). Copies of the relevant test reports are available on request. Actionair electro-mechanical systems should only be installed by qualified and competent technicians, working strictly to the relevant Actionair fitting instructions. Any proposed deviation from the original design or installation instructions must be sanctioned by Actionair's technical staff. System users are advised that servicing or retrospective installation modifications must be undertaken by the installers, or a technically competent contractor who is totally familiar with the relevant system and is in possession of the appropriate Actionair technical data sheets. Trans/Shield ACS Fully Automated Intumescent Fire and Smoke Dampers Alarm Interface Options A or B Connect to a volt free (Normally closed) contact on Alarm Panel ( Opens on Alarm) Connect to 24V D.C. signal from Alarm Panel (Normally on, off in Alarm) Rotar y test switch AUX Talkpac Damper Control Panel Dimensions (Millimetres) 130 160 175 A Specification (ACS-D) 1. The Trans/Shield ACS-D shall comprise of an assembly with three slotted plates, two fixed and one sliding plate allowing air transfer when in the open position. This is fail-safe operated, closed by motorised actuator to prevent the passage of cold smoke in the event of an alarm or power failure. 2. The non-vision grilles each side of the sliding plate assembly are manufactured from P.V.C. slats with an intumescent core. An increase in temperature resulting from either flames or hot gases causes the grille to intumesce, fusing together to provide an effective barrier to the passage of fire and hot smoke. This complies to BS476 Part 20: 1987 for a period of 1 hour and the leakage requirements of BS476 Part 31: Section 31.1. 3. Trans/Shield ACS-D are available in 3 sizes, 200mm x 200mm, 300mm x 300mm and 450mm x 450mm having respective effective free area of 0.012m2, 0.027m2 and 0.061m2. B Specification (ACS-W) 1. The Trans/Shield ACS-W shall comprise of an assembly with three slotted plates, two fixed and one sliding plate allowing air transfer when in the open position. This is fail-safe operated, closed by motorised actuator to prevent the passage of cold smoke in the event of an alarm or power failure. 2. The wall mounted unit incorporates a non combustible housing and intumescent damper: white painted press steel grilles are provided on each side. An increase in temperature resulting from either flames or hot gases causes the damper to intumesce, fusing together to provide an effective barrier to the passage of fire and hot smoke. This complies to BS476 Part 20: 1987 for a period of 2 hours and the leakage requirements of BS476 Part 31: Section 31.1. 3. Trans/Shield ACS-W are available in 3 sizes, 200mm x 200mm, 300mm x 300mm and 450mm x 450mm having respective effective free area of 0.012m2, 0.027m2 and 0.061m2. Regulatory Requirements A p p ro v e d Document B to the Building Regulations (England and Wales) Part E of the Scottish Technical Standards and Part E to the Building Regulations (Northern Ireland) give the requirements for fire and smoke containment with respect to `means of escape'. A study of these requirements shows that practically all internal fire door assemblies are required to prevent the passage of cold smoke. This needs to be considered separately from performance in relation to fire and hot smoke. Air transfer grilles must not compromise the smoke integrity of a doorset. Relevant Standards BS 476 Pt.22: 1987 Methods of determination of the fire resistance of non-loadbearing elements of construction BS 476: Section 31.1 Methods for measuring smoke penetration through a doorset and shutter assemblies BS5588: Fire precautions in the design and construction of buildings. (An Approved Document for compliance with Building Regulations). 11 Trans/Shield ACS w w w . a c t i o n a i r. c o . u k Ordering Procedure Please Specify Quantity Series Accessories Number of units required. ACS-D Door : Trans/Shield ACS with intumescent front and rear grilles. ACS-W Wall : Trans/Shield ACS with white painted steel grilles. TalkPac Panel 2-way communication system. Steel Cover Grilles (white finish) supplied as pairs. Pair intumescent Air Transfer Grilles Rated at 30 minutes 44mm door. Rated at 60 minutes 54mm door. Conductor Hinge Set (1 electrical hinge, 2 stainless steel butt hinges). Battery back-up. Audible alarm. 200 x 200mm 300 x 300mm 450 x 450mm. Aperture Size Wall mounted, rear view of the intumescent damper. Steel Cover Grilles, as supplied with wall mounted ACS-W or as dummy (pair) units. TalkPac Panel, 2-way communication system, full details are on page 8. Example 3 Quantity ACS D Series TALKPAC Accessories 450(W) x 450(H) Aperture Size For further application, technical and pricing information, please refer to Actionair Sales Office. Quality System Certificate No 017 Assessed to ISO 9002 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[36]=new Array("http://www.actionair.co.uk/pdf/air.pdf","Air/Shield Dec_03.qxd","","December 2003 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Actionair Control and Shut Off Dampers Air/Shield Aerofoil Air Control Dampers Air/Shield Aeroseal Air Control and Shut-Off Dampers Energy/Shield ES35 Air Control Dampers Energy/Shield ES36 Air Control and Shut-Off Dampers Air/Shield Features and Design Guide q Opposed blade dampers suitable for systems requiring air control (Aerofoil) and low closed blade leakage (Aeroseal). q Suitable for low/medium pressure and velocity systems. q Available in flanged type casing up to 1000mm square or spigotted type casings up to 1000mm square / 1000mm diameter or flat oval up to 1000mm x 500mm in a single dr ive arrangement. ES35 and ES36 Features and Design Guide q Opposed Blade (standard) or Parallel Blade (optional) dampers suitable for systems requir ing air control (ES35) and low closed blade leakage (ES36). q Suitable for low / medium pressure and velocity systems. q Available in flanged type casing (up to 2080mm x 1000mm in a single drive a r ra n g e m e n t . Dampers Built in Britain Air/Shield (Incorporating Energy/Shield ES35 & ES36) Introduction Actionair has announced a major enhancement to the company's wellproven Air/Shield range of opposed blade dampers. To maximise the potential number of single-module / single-drive configurations, the range has been complemented by the addition of Energy/Shield Dampers for ductwork applications above 1000mm in width. Thus, Energy/Shield ES35 units can now be selected for air balancing requirements for flanged ductwork above 1000mm X 1000mm. Shut off damper requirements for ductwork in these sizes can be met by Energy/Shield ES36 models, where a single drive is required. Smaller sizes are also available in a flanged style casing. For ductwork in sizes below these dimensions the range of Air/Shield Aerofoil (air balancing) and Aeroseal (shut off) Dampers will continue to provide a quality engineered solution. Maximum versatility To ensure maximum versatility of application flanged Energy/Shield ES35 and ES 36 units will be available in 1mm height increments, while specifiers may opt for either opposed blade or parallel blade action according to requirement. For ducts up to 2080mm in width x 1000mm in height these new flanged models can be powered by a single drive to minimise unit cost and maintenance requirements. Blade drive mechanisms are mounted out of the air stream to minimise pressure drop and noise generation. The entire combined range of Air/Shield Aerofoil, Aeroseal and Energy/Shield ES35 and ES36 models is suitable for use with total system operating pressures up to 1000 Pa and velocities up to 12m/s. Casing leakage conforms to DW144 Class C up to 1000 Pa. Product Sizing Aerofoil Air Control Damper Aeroseal Air Control and Shut-Off Damper ES35 Air Control Damper ES36 Air Control and Shut-Off Damper Air/Shield Aerofoil and Aeroseal Flat Oval (single drive arrangement) W idths from 300mm minimum ­ 1000mm maximum, (in 1mm increments). Heights from 100mm minimum ­ 500mm maximum, (in 1mm increments). Energy/Shield ES35 and ES36 FLA (single drive arrangement) W idths from 200mm minimum ­ 2080mm maximum, (in 1mm increments). Heights from 200mm minimum ­ 1000mm maximum, (in 1mm increments). Dampers from 1201mm minimum 2080mm maximum in width will be supplied with a mullion (80mm wide), factory fitted joining strip and hexagonal couplings. This single drive arrangement is supplied as a complete unit. Air/Shield Aerofoil and Aeroseal FLA (single drive arrangement) Widths from 100mm minimum ­ 1000mm maximum, (in 1mm increments). Heights from 100mm minimum ­ 1000mm maximum, (in 50mm increments). Air/Shield Aerofoil and Aeroseal SPG (single drive arrangement ) Widths from 100mm minimum 1000mm maximum, (in 1mm increments). Heights from 100mm minimum ­ 1000mm maximum, (in 1mm increments). Air/Shield Aerofoil and Aeroseal Circular (single drive arrangement) Diameters from 100mm minimum ­ 1000mm maximum (in 1mm increments). 2 Air/Shield Air/Shield The Range The Air/Shield range of quality engineered dampers are suitable for air conditioning and ventilation systems requiring air control and low closed blade leakage characteristics, for standard low/medium pressure and velocity systems. These aerodynamic precise movement opposed blade dampers can be either factory fitted with manual, electric or pneumatic controls and can be supplied in a flanged or spigotted casing. Application Parameters Air/Shield Dampers to maximum width and height dimensions (see page 5) can be used where the operating total system pressure is up to 1000 Pascals and duct velocities to 12m/second. Actionair Air/Shield Dampers are designed for applications in normal dry filtered air systems. When required for modulating function, or if exposed to fresh air intakes and/or inclement conditions, the dampers should be subject to a planned inspection programme. Any application involving corrosive and/or aggressive hostile environmental conditions (e.g. swimming pools) may invalidate our warranty and should be referred to Actionair Sales Office. Blade Features Series Aerofoil Series Aerofoil for system air balancing having aerodynamic ribbed double skin type 1.4016 (430) Ferritic Stainless Steel 50mm wide x 0.4mm thick blades. Housed within a galvanised mild steel flanged or galvanised spigotted casing being suitable for systems with a temperature range of ­20 °C through to +70 °C. Optional Blade construction type 1.4401 (316) Austenitic Stainless Steel. Series Aeroseal Series Aeroseal for system air balancing and shut-off having aerodynamic double skin type 1.4016 (430) Ferritic Stainless Steel 50mm wide x 0.4mm thick blades with synthetic trailing edge blade seals and Stainless Steel side seals. Housed within a galvanised mild steel flanged or galvanised spigotted casing being suitable for systems with a temperature range of 0 °C through to +70 °C. Optional Blade construction type 1.4401 (316) Austenitic Stainless Steel. Blade Drive Mechanism The totally enclosed, precise movement, opposed blade cap and bar drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. 3 Air/Shield Casing Features The damper casing having a single penetration for the drive control shaft making these dampers suitable for inclusion into air distribution systems of Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B, and C (up to 1000 Pa) of HVCA Ductwork Specification DW144. Flanged A 1.5mm thick galvanised mild steel casing having peripheral flanges with pre-punched elongated corner holes to suit proprietary duct flanges. Stainless Steel Options See Dimensional Data and refer to Actionair Sales Office. Spigotted Consists of Flanged Casing above with 0.9mm minimum thickness spigots on both sides. Stainless Steel Options See Dimensional Data and refer to Actionair Sales Office. Please note: Air/Shield Aerofoil and Aeroseal dampers are only available in widths up to 1000mm, please refer to page 5 for full sizing parameters. Where applications involving flanged style dampers requiring widths greater than 1000mm please refer to page 8 which details the ES35 and ES36 flange damper solutions. Weights Air/Shield Aerofoil and Aeroseal Approximate Weights (Kg) SQUARE/ TYPE FLA TYPE SPG TYPE SPG CIRCULAR RECT NGULAR CIRCULAR A DUCT SIZE (mm) 100 150 200 250 300 350 400 450 500 550 600 650 700 1.5 2.0 2.5 3.1 3.8 4.5 5.2 5.8 6.6 7.5 8.4 9.3 10.0 11.3 12.4 13.3 14.7 15.7 16.8 1.8 2.4 3.1 3.8 4.6 5.4 6.3 7.0 7.9 9.0 10.0 11.0 11.9 13.3 14.5 15.6 17.1 18.2 19.4 2.1 2.9 3.8 4.7 5.8 6.9 8.0 9.0 10.3 11.6 13.0 14.4 15.7 17.5 19.2 20.7 22.7 24.3 26.1 Type FLA Square/Rectangular 750 800 850 900 950 1000 Type SPG Square/Rectangular Type SPG Circular For Type SPG Flat Oval weights please contact Actionair Sales Office. Please note: Aerofoil and Aeroseal dampers must not be installed with blades running vertical. Type SPG Flat Oval 4 Air/Shield Dimensions Flanged Casing (Type FLA) Sizing Parameters 65 A/SEAL DUCT HEIGHT + 65 A/FOIL DUCT HEIGHT + 60 18 10 18 10 12 Dia DUCT HEIGHT (IN 50mm INCREMENTS ONLY) 30 10 Dia Airflow Type FLA Widths from 100 ­ 1000mm in 1mm increments. Heights from 100 ­ 1000mm in 50mm increments. Type SPG Rectangular Widths from 100 ­ 1000mm in 1mm increments. Heights from 100 ­ 1000mm in 1mm increments. Type SPG Circular Diameters from 100 ­ 1000mm in 1mm increments. Type SPG Flat Oval Widths from 300 ­ 1000mm in 1mm increments. Heights from 100 ­ 500mm in 1mm increments. 30 30 DUCT WIDTH 30 8 8 Spigot Casing (Type SPG Rectangular, Circular and Flat Oval) SPG Rectangular spigots are supplied 5mm under duct size, Circular and Flat Oval 3mm under duct size. * * * 70 * * 70 * 32 Airflow 32 A B C A = Standard 50mm B = up to 10mm above height increments 50mm height increments * = 38mm Rectangular, 65mm Circular and Flat Oval C = All other cases Stainless Steel Options Spigot Casing (Type SPG Rectangular) SPG Rectangular spigots are supplied 5mm under duct size. Size Parameters as above. Stainless Steel Type FLA Damper casings will have a depth of 150mm with 40mm peripheral flanges (Please refer to Actionair Sales Office). * + OR ­ 11mm FROM A 50mm HEIGHT INCREMENT RESULTS IN A 50mm TOP HAT SECTION. 38 78 38 25 DUCT WIDTH 25 Spigot Casing (Type SPG Circular and Flat Oval) SPG Circular and Flat Oval spigots are supplied 3mm under duct size. DUCT DIAMETER DUCT HEIGHT 25 25* 25 DUCT DIAMETER 25 25 DUCTHEIGHT 25 25* 25 25* DUCT WIDTH 25 65 82 65 * + OR ­ 11mm FROM A 50mm HEIGHT INCREMENT RESULTS IN A 50mm TOP HAT SECTION. 5 Air/Shield Control Options Manual Control (Option M) Always fitted as standard on Series Aerofoil units. Not suitable for Series Aeroseal or any Stainless Steel options. Technical Data Damper Torque The rotation of damper blades from the fully closed to the fully open position produces the greatest torque. The largest torque is also dependent on the fan and system characteristics. Series Aerofoil dampers to the maximum size of 1000mm wide x 1000mm high or 1000mm diameter generally require no more than 10Nm torque. 65 Type FLA/SPG Consists of a red knob and slimline control box with blade position locking facility (a no. 6 pk screw supplied and fitted by others pierces through membrane in the control box) and visual blade position indication. 5 34 98 Series Aeroseal dampers to the maximum size of 1000mm wide x 1000mm high or 1000mm diameter require no more than18Nm torque. The above torques are to rotate the damper from the fully closed to the fully open position against the recommended maximum total system pressure of 1000 pascals and the maximum duct velocity of 12m/s. Manual Quadrant Control (Option Q) Always fitted as standard on Series Aeroseal and also on all Stainless Steel options. Type FLA /SPG Consists of a dark brown steel handle, blade position locking facility and quadrant bracket with visual position indication. 140 Type SPG Stainless Steel 6 183 25 31 62 100 16 47 Extended Shaft Control (Option X) A solid 12.7mm diameter stainless steel shaft marked to provide visual blade indication complete with support bracket for attachment of couplings and/or linkages for motorisation by others. (Shaft rotates clockwise to close damper). 12.7 DIA 58 OPEN OSED CL 12.7 DIA 60 27 16 43 127 143 Electrical Controls (Option E) Factory fitted Belimo Actuators for 24V or 230V open/closed or spring return operation and 24V modulating are available. These will comply with EMC Directive 89/336/EEC. 6 Pneumatic Controls Factory fitted Hytork Pneumatic Actuators are available in on/off and spring return versions. Factory fitted Controls will be selected to suit the torque requirements of the dampers. Please refer to Actionair Sales Office if you require any further information. Air/Shield Pressure Drop Vs Velocity Positions 1, 2 and 3 are blade positions as indicated on dampers fitted with Manual Control or Manual Quadrant Control. 1000 900 800 700 600 500 SERIES AEROFOIL Damper Leakage Air/Shield Series Aeroseal closed blade leakage 1000mm wide x 1000mm high Damper. 1000 Air/Shield Aeroseal Air control and system balancing shutoff dampers comprising of 50mm stainless steel aerodynamic blades with synthetic trailing edge blade seals, synthetic blade end bearings and stainless steel top and side spring tempered flexible gasketing. Dampers to have a maximum closed blade leakage of 27 l/s at 1000 Pa when measured on a 1000mm wide x 1000mm high damper. 3) ION SIT (PO 1/ 4 300 OP EN 400 (PO SIT SERIES AEROSEAL ION 3) EN PRESSURE DROP (Pa) SIT (PO SIT 50 40 30 IO N 100 90 80 70 60 PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 200 500 300 Housed in either a galvanised mild steel frame having integral peripheral flanges, with prepunched corner holes to suit proprietary duct flanges (Type FLA) or with spigot plates on both sides, for square, rectangular, circular or flat oval connections (Type SPG). The totally enclosed precise movement opposed blade drive mechanism positioned out of the airstream for protection against damage is hard wearing and free running. Air/Shield Aeroseal as supplied by Actionair. 1/ 4O P ION 2) 1/ 2 (PO SIT IO 1) N2 ) OP EN 1/ 2 OP EN (PO 250 OP EXAMPLE LINE N1 ) EN 20 IO 3/ 4 200 EN Y SIT LL (PO FU 10 9 8 7 6 5 4 3 EN FU LL Y OP 150 3/ 4 OP 120 100 70 2 Air/Shield Aerofoil dampers are supplied fitted as standard with type Manual Control (Option M). Aeroseal dampers are supplied fitted as standard with type Manual Quadrant Control (Option Q). Stainless Steel dampers are supplied with type Manual Quadrant Control (Option Q) fitted as standard. 1 1 2 3 4 5 6 7 8 9 10 12 50 1 3 5 7 10 15 20 25 30 DUCT VELOCITY (m/s) LEAKAGE (I/s) Specification Air/Shield Aerofoil Air control and system balancing dampers comprising of 50mm ribbed stainless steel aerodynamic blades with synthetic blade end bearings. Housed in either a galvanised mild steel frame having integral peripheral flanges, with prepunched corner holes to suit proprietary duct flanges (Type FLA) or with spigot plates on both sides, for square, rectangular, circular or flat oval connections (Type SPG). The totally enclosed precise movement opposed blade mechanism positioned out of the airstream for protection against damage is hard wearing and free running. Air/Shield Aerofoil as supplied by Actionair. Air/Shield dampers can be factory fitted with one of the alternative control options as detailed on page 6 (Aeroseal and Stainless Steel dampers not suitable for Option M). 7 Energy/Shield ES35 & ES36 Energy/Shield ES35 & ES36 The Range The Energy/Shield ES35 & ES36 range of Flanged dampers are suitable for air conditioning and ventilation systems requiring air control and low closed blade leakage characteristics, for low / medium pressure and velocity systems. These aerodynamic precise movement opposed blade (parallel blade optional) dampers can be either fitted with manual, electric, pneumatic or extended spindle controls. Application Parameters Energy/Shield Flanged ES35 and ES36 to maximum width (2080mm) and height (1000mm) dimensions can be used where the operating total system pressure is up to 1000 Pa and duct velocities of 12m/s. Energy/Shield ES35 and ES36 Flanged dampers are designed for applications in normal dry filtered air systems. When required for modulating function, or if exposed to fresh air intakes and/or inclement conditions, the dampers should be subject to a planned inspection programme. Any application involving corrosive and/or hostile environmental conditions (e.g. swimming pools) may invalidate our warranty and should be referred to Actionair Sales Office. Blade Features Series ES35 Series ES35 for air control having aerodynamic triple ­ vee 1.6mm thick x 157mm wide galvanised steel blades. Housed in a 1.2mm thick x 160mm deep galvanised steel frame with 40mm flanges, with pre-punched corner holes to suit proprietary duct flanges, suitable for systems with a temperature range of ­40°C to +116°C. Please note actuators: this may exceed certain actuator temperature ranges. Control Options 12.7 DIA 90 40 124 160 Extended Shaft Control (Option X) 12.7mm diameter x 150mm Zinc plated steel Extended Spindle for motorised control. Supplied as standard. Loose for site fitting by others. 97 97 Series ES36 Series ES36 are similar to that of the ES35 except having stainless steel side gasketting and synthetic blade seals, resulting in low closed blade leakage. Also the operating temperature range is -40°C to +70°C. Please note actuators: this may exceed certain actuator temperature ranges. 30 146 Manual Quadrant Control (Option Q) Manual Quadrant Control. Supplied loose for site fixing by others. Blade Drive Mechanism Blade Drive Mechanism is mounted out of the airstream to minimise pressure and noise generation, blade axles are 11.1mm hexagonal zinc plated steel. Synthetic blade bearings give a corrosion resistant, hard wearing and free running operation Electrical Controls (Option E) Belimo Actuators for 24V or 230V open/closed or spring return operation and 24V modulating are available. 8 135 Energy/Shield ES35 & ES36 Casing Features The flanged damper casing having a single penetration for the drive control shaft makes these dampers suitable for inclusion into air distribution systems, casing leakage conforms to DW144 Class C up to 1000 Pa. The casing consists of 1.2mm thick x 160mm deep galvanised steel frame with 40mm flanges pre-punched corner holes to suit proprietary duct flanges. Single Drive Arrangement Dampers with widths from 200mm 2080mm and heights from 200mm 1000mm will be supplied with a single drive. Dampers having a width dimension from 200mm 1200mm will be supplied without a mullion. Dampers having width from 1201mm - 2080mm will be supplied with a single drive centre mullion, factory fitted joining strips and blade drive coupling. Multiple Width Configuration These are available as two single units, up to a maximum of 4240mm wide and are driven from each side. these multiple width arrangements are supplied with joining strips (galvanised 1.2mm thick x 75mm wide) for on site fixing by others. For large assemblies additional support may be required. Please refer to Actionair Sales Office for multiple height configurations. Please note ES35 and ES36 single or multiple dampers must not be installed with the blades running vertical. Dimensions Single Drive (no mullion) 160 27.5 17.5 17.5 200 mm - 1000 mm Height Single Drive 27.5 * OVERALL DAMPER HEIGHT (= DUCT HEIGHT + 80mm) 12 Dia 40 Width 40 200mm - 1200mm 40 10 10 * Top and bottom blade when open protrude on both side sides beyond casing, see below. Height 200 225 375 525 650 675 800 950 Overhang 16 27 16 27 16 27 16 16 Single Drive (including 80mm central mullion with, factory fitted joining strips and blade drive couplings) 40 Single Drive 80 200 mm - 1000 mm Height Width 40 1201mm - 2080mm 40 Size Parameters Available in 1mm increments Single drive arrange Widths from 200mm - 2080mm Heights from 200mm - 1000mm. 9 40 Energy/Shield ES35 & ES36 Technical Data ES35 and ES36 Graphs showing Pressure Drop Vs Velocity at intermediate Blade positions. E/S. 35/R ES36R (Opposed Blade) 1000 500 /4 O PE N Specification Energy/Shield ES35 Air control dampers comprising of 157mm triple vee galvanised blades with synthetic blade bearings. Housed in a galvanised steel frame having integral peripheral flanges, with pre-punched corner holes to suit proprietary duct flanges. The opposed blade and parallel blade (optional) drive mechanism is mounted out of the airstream. Energy/Shield ES35 as supplied by Actionair. Energy/Shield ES36 Air control and shut-off dampers comprising of 157mm triple vee galvanised blades with synthetic blade seals and stainless steel side gasketting. Housed in a galvanised steel frame having integral peripheral flanges, with pre-punched corner holes to suit proprietary duct flanges. The opposed blade and parallel blade (optional) drive mechanism is mounted out of the airstream. Energy/Shield ES36 are supplied by Actionair. E/S. 35/P E/S 36/P (Parallel Blade) 1000 500 200 100 200 100 50 1 1 PRESSURE DROP (Pa) PRESSURE DROP (Pa) PE 1 50 /2 O /4 O 1 PE /2 O PE N N PE N /4 O 20 10 5 20 10 5 N 3 3 /4 O PE N N FU LL Y 2 2 0.5 2 5 1 DUCT VELOCITY (m/s) 10 0.5 2 5 1 DUCT VELOCITY (m/s) FU LL Y OP E OP E N 10 Damper Torques The rotation of damper blades from fully closed to the fully open position produces the greatest torque. The largest torque is also dependent on the fan and system characteristics. Series Energy/Shield ES35 and ES36 Dampers to the maximum size of 1000mm wide x 1000mm high generally require no more than 10Nm torque. For sizes above this to a maximum size of 2080mm wide x 1000mm high require no more than 18Nm torque, The above torques are to rotate the damper from the fully closed to the full open position against the recommended maximum total system pressure of 1000 pascals and the maximum duct velocity of 12 m/s. Damper Leakage ES36 1000mm wide x 1000mm high Damper 1000 Weights ES35 and ES36 Approximate Weights (Kg) Height 200 200 3.8 6.8 8.6 10.2 12.6 400 5.4 9.5 11.8 14.0 17.4 Width 600 7.1 12.2 15.0 17.7 22.1 800 8.7 15.0 18.2 21.4 26.8 1000 10.4 17.7 21.4 25.2 31.5 500 DIFFERENTIAL PRESSURE (Pa) 200 400 600 800 50 100 1000 20 10 1 2 5 10 20 LEAKAGE (I/s/m2) 50 100 10 Air/Shield (Incorporating Energy/Shield ES35 & ES36) Selection Please refer to individual sections of the brochure for specific product detailed information. Flanged Style Casing - Minimum 100 x 100 (Height increments of 50mm) Flanged Style Casing - Minimum 200 x 200 (Height increments of 1mm) Flanged Style Casing - Maximum 1000 x 1000 Flanged Style Casing - Maximum 2080 x 1000 30mm Flange Style 40mm Flange Style Flanged Casing Depth - 65mm Flanged Casing Depth - 160mm Spigotted Style Casing - Maximum 1000 x 1000 Circular Option - Maximum 1000 dia. Flat Oval Option - Maximum 1000 x 500 Air Balancing Only Shut-off Function Opposed Blade Movement Parallel Blade Movement (Optional) Manual Geared Control (Standard for Aerofoil) Manual Quadrant Control (Standard for Aeroseal) Extended Spindle Control (Standard for ES35 and ES36) Electrical Control (Optional) Blade Drive Mechanism mounted out of the airstream Casing Leakage Conforms to DW144 Class C up to 1000Pa Galvanised Case with Stainless Steel Blades (Standard) Galvanised Case with Galvanised Blades (Standard) Aerofoil q q q q q q q q q q q q q q q q Aeroseal q q ES35 q q ES36 q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q Electrical Controls (Option E) Open / Close (24/240V) 4Nm 8Nm 18Nm LM NM AM Air/Shield Aerofoil Up to 0.25m sq (square/rectangular/ From 0.26m sq to 1m sq Flat Oval) Air/Shield Aerofoil (Circular) Up to 500mm dia From 501mm dia to 1000mm dia q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q q Modulating (24V) 4Nm 8Nm 18Nm LM NM AM q q q q q q q Spring Return (24/240V) 4Nm 15Nm LF AF q q Air/Shield Aeroseal Up to 0.09m sq (square/rectangular/ From 0.091m sq to 0.25m sq Flat Oval) From 0.26m sq to 1m sq Air/Shield Aeroseal (Circular) Up to 300mm dia From 301mm dia to 500mm dia From 501mm dia to 1000mm dia Energy/Shield up to 0.32m sq ES35 FLA From 0.32m sq to 1.0m sq (Square/Rectangular) From 1.0m sq to 2.16m sq Energy/Shield Up to 0.16m sq ES36 FLA From 0.16m sq to 0.64m sq Square/Rectangular) From 0.64m sq to 2.16m sq 11 Air/Shield (Incorporating Energy/Shield ES35 & ES36) w w w . a c t i o n a i r. c o . u k Standard Ordering Procedure Air/Shield Quantity Series Type Control Options Number Required. Air/Shield Aerofoil or Air/Shield Aeroseal. FLA-Flanged Casing or SPG-Spigotted Casing, in Rectangular, Circular or Flat Oval Configuration. M Manual Control (fitted as standard to Series Air/Shield Aerofoil). Q Manual Quadrant Control (always fitted as standard to Series Air/Shield Aeroseal and Stainless Steel options). E Electrical Operator. 24V or 230V open/closed 24V or 230V spring return or 24V modulating. X Extended Shaft Control. Example 2 Quantity / Air/Shield Aeroseal Series / FLA Type / Q Control Option / 800(W) x 400(H) Duct Size Standard Ordering Procedure ES35 ES36 Quantity Series Operation Control Options Number Required. Energy/Shield ES35 or Energy/Shield RS36 (Flanged style casing only) R Opposed Blade Movement P Parallel Blade Movement Q Manual Hand Quadrant E Electrical Operator. 24V or 230V open/closed 24V or 230V spring return or 24V modulating. X Extended Shaft Control (Fitted as standard on ES35 and ES36). Example 2 Quantity / Energy/Shield ES35 Series / R Operation / X Control Option / 1400(W) x 400(H) Duct Size For further application, technical and pricing information, please refer to Actionair Sales Office. PRODUCED BY GRAPHIC PARTNERSHIP 01227 280877 no compromise... Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited Quality System Certificate No 017 Assessed to ISO 9001:2000");sQ1[37]=new Array("http://www.actionair.co.uk/pdf/marine.pdf","A-60_Marine May 04.qxd","","May 2004 A- 60 Marine Fire Dampers A-60 Marine Fire Damper Features and Design Guide Tested and approved for class A-60 divisions (bulkheads and decks) with a minimum length of 600mm insulation. Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3. Complies to Marine Equipment Directive 96/98/EC. Corrosion tested to BS EN 60068-2-52, Severity 2 conditions. Vibration tested to BS EN 60068-2-6 (5Hz ­ 350Hz @ 2g). 40mm flanged style casing in rectangular or circular format. Size range from 100mm x 100mm to 1000mm x 1000mm (single module), with a multiple approved size of 1580mm x 1000mm. Choice of either 24, 120 or 230 Volt electrical Control Modes. Pneumatic version available. Control Mode multi-position feature (up to and including 400mm high) to allow onsite installation flexibility. The A-60 Marine Fire Damper is designed for inclusion in air conditioning and ventilation systems. Actionair Designed for inclusion in Marine and Offshore Projects 0038-00038/04 Dampers Designed and Built in Britain A- 60 Marine Fire Dampers Introduction Actionair has, for many years, been associated in the design, development and manufacture of life safety equipment, including the supply of fire damper products to the offshore and marine industry. The Actionair A-60 Fire Damper has been specifically engineered to meet stringent legislation. The A-60 Marine Fire Damper compliments the comprehensive range of automatic fire and smoke dampers and associated controls, provides the complete solution for shipboard air conditioning and ventilation systems fire safety engineering strategies. The A-60 Marine Fire Damper has been designed for inclusion in air conditioning and ventilation systems and is tested and approved for fitting to class A-60 divisions (bulkheads and decks), with a minimum length of 600mm insulation, for vertical application and 400mm insulation for horizontal application. STRUCTURAL STEEL CORE 75 75 150 40 300 600 (MINIMUM) 400 (MINIMUM) 40 CONNECTION OF DAMPER TO COAMING MINERAL FIBRE INSULATION (110Kg PER CUBIC METRE) 50 DAMPER 25 40 COAMING 50 DAMPER COAMING Bulkhead (Vertical) Deck (Horizontal) Range and Application Electrical and Pneumatic The A-60 dampers can be used where the maximum system pressure is up to 2000 Pa and duct velocities to 15m/s. A-60 Marine Fire Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions please refer to Actionair Technical Sales Office. Electrical The A-60 Marine Fire Damper is suitable for both vertical and horizontal applications, with airflow in either direction. The dampers which are A60 fire rated to IMO Fire Test procedures Code, Annex 1 Pt 3, are normally open, and fail-safe to the closed position. Fail-safe is by means of a unique and patented Electrical Thermal Release (ETR) which operates at 72 °C, or if power supply is interrupted. The ETR incorporates a safety feature, including that ensures the fail-safe status of the damper if the ETR is not fitted on to the ductwork. A manual test switch allows periodic operation of the damper for testing purposes, simulating actual fail-safe release under fire conditions. The associated electrical control modes are available in 24 Volt, 120 Volt or 230 Volt versions. Pneumatic The A-60 Marine Fire Damper is suitable for both vertical and horizontal applications, with airflow in either direction. The dampers which are A60 fire rated to IMO Fire Test procedures Code, Annex 1 Pt 3, are normally open, and fail-safe to the closed position. Fail-safe is by means of a unique and patented Pneumatic Thermal Release (PTR) which operates at 74 °C, or if power supply is interrupted. The PTR incorporates a safety feature, that ensures the fail-safe status of the damper if the PTR is not fitted on to the ductwork. Electrical Thermal Release (ETR) Pneumatic Thermal Release (PTR) 2 150 225 25 40 CONNECTION OF DAMPER TO COAMING 75 A-60 Marine Fire Dampers Specification Electrical A-60 Marine Fire Damper is constructed from galvanised steel 1.2mm thick, 40mm flanged rectangular or circular casing, (316 stainless steel option available). 75mm interlocking 430 grade stainless steel aerodynamic blades, steel blade end bearings and 300 grade stainless steel peripheral gasketting. (316 grade stainless steel blade and blade end bearing available). The totally enclosed precise movement opposed blade drive shall be positioned out of airstream for protection against damage, be hard wearing and free running. Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3, for class A60 bulkheads and decks. Direct coupled Control Modes available in 24, 120, or 230 Volt options fitted with low smoke and fume electrical cables. An Electrical Thermal Release (ETR) rated at 72 °C will provide spring fail safe closed operation. A safety electrical interlock to ensure correct operation only when ETR is properly fitted to duct. A manual test switch allowing periodic operation of the damper for testing purposes simulates actual fail-safe release under smoke/fire conditions Pneumatic A-60 Marine Fire Damper is constructed from galvanised steel 1.2mm thick, 40mm flanged rectangular or circular casing, (316 stainless steel option available). 75mm interlocking 430 grade stainless steel aerodynamic blades, steel blade end bearings and 300 grade stainless steel peripheral gasketting. (316 grade stainless steel blade and blade end bearing available). The totally enclosed precise movement opposed blade drive shall be positioned out of airstream for protection against damage, be hard wearing and free running. Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3, for class A60 bulkheads and decks. Testing The Actionair A-60 Marine Fire Damper 750mm x 750mm single module damper and a 1200mm x 750mm multi width damper assembly, were fire tested at the BRE facility in Borehamwood. The dampers were incorporated in a steel A60 bulkhead and were submitted to a marine fire resistance test in accordance with IMO Resolution A.754 (18) for a duration of 60 minutes. A similar test was performed in a deck of the same construction, enabling the unit to be suitable for both vertical and horizontal applications. 3 A-60 Marine Fire Dampers Casing Features The standard 1.2mm galvanised steel flanged type casing, having a single penetration for the drive control, complies to Class A & B of Eurovent 2/2 and Test Procedures for Classes A, B ,& C of the HVCA Ductwork Specification DW144. 12mm diameter pre-punched corner and intermediate boltholes are provided as standard (Rectangular Dampers). In addition Stainless Steel peripheral gasketing is included, which allows for expansion under full fire conditions. The 1.2mm casing has obvious benefits, for example being lighter in weight, allowing easier installation. Casings manufactured in Type 1.4401 (316 grade) Austenitic Stainless Steel are available as an optional extra. The damper blades are aerodynamic double skin, type 1.4016 (430 grade) Ferritic Stainless Steel, which are 75mm wide and interlocked to form a positive fire resisting shield. Incorporated in the blade are steel blade end bearings. Optional blades in Type 1.4401 (316 grade) Austenitic Stainless can be provided. Incorporated in the blade are 316 Stainless Steel blade end bearings. 12.7 Blade Features Optional Silicon blade seals can be provided for low leakage requirement at ambient temperature. 4 75 41.5 A-60 Marine Fire Dampers Control Modes The IP54 rated Control Modes, are located outside of the ductwork for ease of access and installation. Control Modes fitted to dampers up to 400mm high, can be fitted in any one of three orientations i.e. vertically down, horizontally or vertically up. Two sizes (Compact and Universal) of Control Mode are utilised. Correctly sized Control Modes are designed to fit only to the relevant sized damper. This flexibility ensures that the smaller damper sizes and control mode require the minimal amount of room. For damper sizes above 400mm high the control mode is fitted vertically. DAMPER DRIVE SHAFT MOUNTING PLATE ADAPTOR PLATE 150 85 Position 3 Position 2 LABEL SIDE Position 1 30 100 Fig. 1 Three Position Compact 150 123 Position 3 Control Mode Standard Parameters Position 2 Dampers up to 400mm high:­ up to 400mm wide ­ Fig.1 above 400mm wide ­ Fig.2 Dampers above 400mm high:­ Fig. 3 Position 1 Fig. 2 Three Position Universal 100 LABEL SIDE Fig. 3 Single Position Universal Electrical Thermal Release (ETR) Application and Wiring Control Mode 5 24V A.C. or D.C. Control Mode 6 230V A.C. 50/60Hz Control Mode 120 120V A.C. 50/60Hz Power On ­ Damper motors open. Power Off ­ Damper springs closed. ETR Operates ­ Damper springs closed. Release Time 20 seconds. Reset Time less than 150 seconds. 8W (Maximum Motoring) 3W (Maximum Reset). Limit Switches Rated at 250V 1.5 Amp (Maximum). M 1 Position Actuator LIMITSWITCH CONTACTS SHOWN ARE WITH CONTROL MODE IN DAMPER CLOSED POSITION 1 N SUPPLY 2 S1 L To isolate from main power supply, the system must incorporate a device, which disconnects the phase conductors, with at least 3mm contact gap. 2 x 1 metre of halogen free, low smoke and fume electric cables are included with each control mode. The ETR is also prewired with 0.5 metre halogen free low smoke and fume cable. COMMON CLOSED OPEN COMMON CLOSED OPEN TF 72 °C S2 VOLT FREE CONTACT CHANGES OVER AT 5° S3 S4 S5 VOLT FREE CONTACT CHANGES OVER AT 85° S6 ELECTRICAL THERMAL RELEASE (ETR) SPRING BIASED TEST SWITCH 248 LABEL SIDE 155 5 A- 60 Marine Fire Dampers Dimensional Data Pneumatic Spring return and double acting units Pneumatic Thermal Release (PTR) C D E 4mm Dia. 500mm long connection to actuator. A B G F Model XL71 A 115 B 95 C 57 D 59 E 222 F 29 G 102 INPUT: 6mm Dia. Quick release connector, pressure range 5 ­ 8 Bar. Square and Rectangular (A-60 RECT) 150 50 MIN 75 MAX 150 150 150 MIN 75 MAX 150 Circular (A-60 CIRC) 230 40 40 DAMPER DIA 100 -1000 Electrical Actuator 25 56 8 DAMPER DIA 100 -1000 40 DAMPER HEIGHT 100 -1000 150 40 20 40 DAMPER WIDTH 100 - 1000 MINIMUM REMOVAL DIMENSION 90mm 40 20 Pneumatic Actuator 20 Circler Damper Fixing Hole Details Damper Dia. No. of Holes PLEASE NOTE THE NUMBER OF 12MM DIA. HOLE DRILLINGS IS DEPENDENT ON THE DAMPER SIZE Hole Dia. 7.0 10.0 12.0 150 25 8 100 - 250 251 - 500 501 - 750 751 - 1000 4 off 8 off 12 off 16 off 12.0 Please Note: Size 751 - 1000mm for horizontal applications only. 40 PLAN VIEW CROSS SECTION SHOWING CONTROL MODE DIMENSIONS MINIMUM REMOVAL DIMENSION 90mm All dimension are in millimetres 6 78 14 100 78 14 A-60 Marine Fire Dampers Multiple Assemblies DAMPER WIDTH 50 TOP DAMPER HEIGHT Multiple width assemblies (2 x 1) have been tested and approved to a size of 1580mm wide x 750mm high (vertical) and 1580mm wide x 1000mm high (horizontal). Steel joining strips for fitting both sides of the damper multiple assembly are supplied for site fixing by others. MOTOR 12mm DIA. HOLES IN EACH CORNER AND EQUALLY SPACED AT 150mm MAX. CENTRES BOTH SIDES OF FLANGES ON EACH INDIVIDUAL DAMPER 20 20 150 40 FLANGE ALL AROUND 1.2 STEEL x 75mm WIDE JOINING STRIP. (BOTH SIDES) RIVETTED WITH 3.2mm STEEL RIVETS AT 100mm CENTRES, ON SITE BY OTHERS Weights Calculated Weights (Kg) of A-60 Rectangle (Excluding Actuator) Vertical Installation (Bulkhead) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 3.8 4.1 4.4 5.0 5.7 6.0 6.6 7.3 7.6 8.2 8.9 9.2 9.9 150 4.2 4.5 4.8 5.4 6.1 6.4 7.0 7.7 8.0 8.6 9.3 9.6 10.3 200 4.6 4.9 5.2 5.8 6.5 6.7 7.4 8.1 8.4 9.0 9.7 250 5.1 5.3 5.6 6.3 7.0 7.3 8.0 8.7 9.0 9.7 10.4 300 350 400 5.5 5.8 6.1 6.8 7.5 7.8 8.6 9.3 9.6 6.0 6.3 6.5 7.3 8.1 8.3 9.1 9.9 6.4 6.7 7.0 7.8 8.6 8.9 9.7 10.5 450 500 6.9 7.2 7.4 8.3 9.1 9.4 7.4 7.6 7.9 8.7 9.6 9.9 550 600 7.8 8.1 8.4 9.2 8.3 8.5 8.8 9.7 650 8.7 9.0 9.3 10.2 11.2 11.5 12.5 13.5 13.8 14.8 15.8 16.1 17.1 18.1 18.4 19.4 20.4 20.6 21.6 700 9.2 9.4 9.7 10.7 11.8 12.0 13.1 14.1 14.4 15.4 16.5 16.7 17.8 18.8 19.1 20.1 21.2 21.5 22.5 750 9.6 9.9 10.2 11.2 12.3 12.6 13.6 14.7 15.0 16.1 17.2 17.4 18.5 19.6 19.9 20.9 22.0 22.3 23.4 Horizontal Installation (Deck) 800 10.1 10.4 1.6 11.7 12.8 13.1 14.2 15.3 15.6 16.7 17.8 18.1 19.2 20.3 20.6 21.7 22.8 23.1 24.2 850 900 950 1000 10.5 11.0 11.5 10.8 11.3 11.7 11.1 11.5 12.0 12.2 12.7 13.2 13.3 13.9 14.4 13.6 14.1 14.7 14.8 15.3 15.9 15.9 16.5 17.1 16.2 16.8 17.4 17.4 18.0 18.6 18.5 19.2 19.9 18.8 19.4 20.1 19.9 20.6 21.4 21.1 21.8 22.6 21.4 22.1 22.8 22.5 23.3 24.1 23.7 24.5 25.3 23.9 24.7 25.6 25.1 25.9 26.8 11.9 12.2 12.5 13.7 14.9 15.2 16.5 17.7 18.0 19.3 20.5 20.8 22.1 23.3 23.6 24.9 26.1 26.4 27.7 Calculated Weights (Kg) of A-60 Circler (Excluding Actuator) 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 5.2 6.4 7.6 9.4 11.2 12.7 14.7 16.9 18.5 20.8 23.2 24.9 27.5 30.2 32.1 34.9 37.8 39.9 43.0 78 10.2 10.7 10.4 11.0 11.4 11.9 12.3 12.9 12.6 13.2 13.5 14.2 14.5 15.1 14.7 15.4 15.7 16.4 16.6 17.3 16.9 17.6 17.8 18.6 18.7 19.6 19.0 19.8 19.9 20.8 10.2 10.8 11.1 11.7 11.4 12.0 12.2 12.9 13.1 13.8 13.4 14.0 14.2 14.9 15.1 15.8 15.4 16.1 16.2 17.0 17.1 17.9 17.4 18.2 18.2 19.1 10.2 10.8 10.3 11.0 11.6 11.1 11.8 12.4 11.3 12.0 12.7 12.1 12.8 13.5 12.8 13.6 14.3 13.1 13.9 14.6 13.9 14.7 15.4 14.6 15.4 16.3 14.9 15.7 16.5 15.6 16.5 17.4 3.00kg 1.85kg 10.0 10.7 10.7 11.4 11.4 12.1 11.6 12.4 12.3 13.1 13.0 13.8 13.2 14.1 13.9 14.8 10.5 10.9 10.8 11.2 11.5 11.9 12.2 12.6 12.4 12.8 1000 13.1 13.5 Mode 5 Mode 5L plus Adaptor Plate plus Adaptor Plate Note: Shaded Area : Horizontal Installation (Deck) 7 A-60 Marine Fire Dampers Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of A-60 Marine Fire Dampers. A programme of extensive tests was carried out by an independent test facility, approved under the NAMAS Scheme, in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Table 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Table 2). The graph is the result of a full range of acoustic tests with the blades set in the fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) is obtained. Example: Duct with a design velocity of 8 m/sec and the A-60 Marine Fire Damper RECT damper blades in the fully open position. Pressure Drop = 22 Pa (Table 1). Multiply Velocity x Pressure Drop 8 x 22 = 176. From Sound Power Graph (Table 2) plot 176 on horizontal Velocity/Pressure axis against the A-60 Marine Fire Damper RECT outlet (induct) graph to obtain 47 dBW on Vertical Sound Power Level Axis. Add or subtract corrections to the 47dBW to provide full spectrum analysis. Damper Leakage Table 3 A-60 Marine Fire Damper damper closed blade leakage. Standard (without blade seals) Optional (with blade seals) 2000 1500 1000 500 DIFFERENTIAL PRESSURE (Pa) 100 10 1 10 50 100 200 LEAKAGE (I/s per m2) Pressure Drop Vs Velocity Table 1 100 90 80 70 60 50 40 Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) Table 2 90 80 ) CT DU (IN ET TL ) OU CT C IR DU (IN 0C ET -6 A TL OU CT RE 0 A-6 EXAMPLE LINE 70 30 EXAMPLE LINE SOUND POWER LEVEL (dBW) PRESSURE DROP (Pa) 20 A-6 0R EC T A-6 0C IRC 60 50 10 9 8 7 6 5 4 3 2 40 EC R TB EA KO UT 30 A-6 0R 20 A-6 0C IR R CB EA KO UT 10 1 1 2 3 4 5 6 7 8 9 10 15 0 4000 5000 6000 7000 8000 9000 10000 400 500 600 700 800 900 1000 40 50 60 70 80 90 100 2000 3000 200 300 10 20 30 VELOCITY (m/s) VELOCITY X PRESSURE DROP (m/s Pa) Outlet (Induct) Spectrum Corrections Octave Band63 125 250 500 1k 2k 4k 8k A-60 RECT 5 4 5 5 3 1 -3 -5 A-60 CIRC 944 5 3 1 -3 -6 Breakout Spectrum Corrections 63 125 250 500 1k 2k 4k 8k Hz 8 11 9 6 -3 -6 -14 -17 dB 6 10 8 4 -3 -3 -11 -14 dB 8 A-60 Marine Fire Dampers Certification Copies of Lloyds Fire Certification for A-60 Marine Fire Damper Approvals 9 A-60 Marine Fire Dampers Certification Copies of Lloyds Fire Certification for A-60 Marine Fire Damper Approvals 10 A-60 Marine Fire Dampers Certification Copies of Germanischer Lloyds Fire Certification for A-60 Marine Fire Damper Approvals 11 A- 60 Marine Fire Dampers w w w . a c t i o n a i r. c o . u k Standard Ordering Procedure Please Specify Series A- 60 RECT(Galv) A- 60 Marine Fire Damper 430 Ferritic Stainless Steel Blades. Square or Rectangular Flanges. Galvanised Casing. A- 60 CIRC (Galv) A- 60 Marine Fire Damper 430 Ferritic Stainless Steel Blades. Circular Flanged . Galvanised Casing. A- 60 RECT (316) A- 60 Marine Fire Damper 316 Austenitic Stainless Steel Blades. Square or Rectangular Flanges. Stainless Steel Casing. A- 60 CIRC (316) A- 60 Marine Fire Damper 316 Austenitic Stainless Steel Blades. Circular Flanged. Stainless Steel Casing. Control Modes Control Mode 5 Control Mode 6 Control Mode 120 Pneumatic 24V A.C. or D.C. 230V A.C. 50/60Hz 120V A.C. 50/60Hz 24V Solenoid Seals Standard (without blade seals) Optional (with blade seals) Flange Holes Drilled (Standard) Undrilled (Optional) Accessories (Electrical) CB Connection Box For Control Modes . PBOB Push Button Operator Box For Control Modes. DTU Damper Test Unit For Control Modes. Example 3 I Quantity / A- 60 RECT (Galv) I Series / 400 (W) x 250 (H) I Duct size / M5 / Standard Undrilled I Options / DTU I Control Modes I Accessories no compromise... Quality System Certificate No 017 Assessed to ISO 9001 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.co.uk");sQ1[38]=new Array("http://www.actionair.co.uk/pdf/AirShieldCircular.pdf","May 07 Circulair.qxd","","May 2007 Circulair Circulair Series Air Balancing Dampers Features G Manual Control G Extended bracket to suit insulated Ducts. G Common Casing Depth of 170 mm. G Eurovent Duct Sizes: 100-315 mm Dia. G Stock Item. G Suitable for inclusion into air distribution Systems to HVCA Ductwork specification as follows:­ Casing leakage conforms to DW144 up to 1000 Pa. Class B or C depending on dia. G Damper Spigots Conform to BSEN1506. Dampers Controls Fancoils Ruskin Air Management Limited www.ruskinuk.co.uk Circulair Specification Actionair Circulair/Balance dampers comprise of a single 1.2 mm galvanised steel blade housed within a 0.9 mm galvanised steel casing. Complete with Manual Control. Dimensions and Weights 170 30 70 30 2 OFF 9MM WIDE STRENGTHENING RIBS A NOMINAL DUCT DIAMETER 50 77 50 Manual Control Complete with damper blade position indicator. A Nom sizes (mm) 100 125 150 160 200 250 300 315 Open blade protrusion ­ ­ ­ ­ 15 40 65 72.5 Casing leakage Class B B B B B C C C Weight (Kg) 0.55 0.68 0.82 0.88 1.12 1.45 1.81 1.92 BROCHURE PRODUCTION www.geoffstrange.co.uk LNNN30786 Model ref C/B C/B C/B C/B C/B C/B C/B C/B Ordering Information Example Quantity 2 Series Circulair Type Balance Size 125mm Ruskin Air Management Limited South Street, Whitstable, Kent CT5 3DU England. Tel: 01227 276100 Fax: 01227 264262 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[39]=new Array("http://www.actionair.co.uk/pdf/industrial.pdf","industrial.pdf","","April 2002 H e a v y Duty Steel and Fibreglass Dampers RUSKIN Industrial and Tunnel Ventilation Dampers Industrial and Tunnel Ventilation Dampers Introduction For over 40 years, Ruskin has been the leader in designing and manufacturing durable, high performance dampers for industrial and tunnel ventilation applications. Because Ruskin customers deserve the highest quality products, Ruskin has developed an on-site A.M.C.A (Air Movement Control Association) registered air performance laboratory. Located in Kansas City, Missouri, this test facility has three high capacity wind tunnels, including the largest test tunnel in the industry. These test tunnels help Ruskin simulate demanding wind and air handling situations and are ideal for testing leakage and pressure drop. Ruskin's goal is to deliver products that meet and exceed industry standards. Experienced, professional engineers, and development, and the latest in manufacturing technology are the key ingredients that assure superiority of Ruskin products. With a history of developing original ideas, Ruskin is known for its innovation and use of leading-edge technology. This includes using the latest materials to custom build dampers and louvers to withstand the most stringent environments. Ruskin products are installed in NASA applications, hi-pressure transit tunnels, and highly corrosive environments such as naval ships and waste water treatment facilities. Ruskin Air Management Limited In January 2000, Actionair, the leading manufacture of HEVAC dampers in the UK, became part of Ruskin Air Management Limited. This has enabled Actionair and Ruskin to work closely together and now Actionair can offer the complete range of Ruskin Industrial and Tunnel damper products under the banner of Ruskin Air Management Limited. Ruskin / Actionair association for UK and Europe. Heavy Duty Control Dampers Damper Model CD80AF4 Standard Construction Description · Galvanised construction · Welded 2.6mm up to 1219mm wide, 3.25mm 1219mm to 1524mm airfoil blade · 19mm axles up 1220mm blade width, 25mm axle 1220mm to 1524mm · 203mm x 50mm x 3.25mm channel flange frame · Stainless steel sleeve bearing bolted to frame · Galvanised construction · Welded 1.6mm up to 1220mm wide, 2mm 1220mm to 1524mm airfoil blade · 19mm axles · Stainless steel sleeve bearing bolted to frame · 203mm x 50mm x 2.6mm flange frame · 203mm x 50mm x 2mm galvanised channel frame · 19mm plated axles · Stainless steel press fit bearings · 3.25mm galvanised steel clevis side linkage · Max. single section 1524mm w x 2438mm h · 203mm x 50mm x 2mm galvanised channel frame · 13mm plated axles · Stainless steel press fit bearings · 3.25mm galvanised steel clevis side linkage · Max. single section 1220mm w x 2438mm h · 205mm x 50mm x 2mm galvanised channel frame · 19mm plated axles · 1.6mm triple vee groove galvanised blades · Concealed side linkage · Stainless steel press fit bearings Damper Width (mm) Max. System (Single Sections)* Pressure (Pa) 1524 1219 914 610 310 5000 6500 8000 9000 11000 Max. System Velocity (m/s) 25.4 25.4 25.4 30.4 30.4 Leakage With/Without Seals (CFM) 20 20 20 40 65 160 160 160 200 300 Temperature Range (°C)** 121 °C to 204 °C Applications Fan discharge Isolation Stack Isolation CD80AF3 High Pressure Thermal Oxidzer Fans Fan Intake 1524 1219 914 610 305 1524 1219 914 610 305 1219 914 610 305 3500 4700 6000 7200 8500 3000 4200 5500 6700 8000 2500 3700 4800 6000 25.4 25.4 25.4 30.4 30.4 20.3 20.3 20.3 25.4 30.4 20.3 20.3 25.4 30.4 20 20 20 40 65 20 20 20 40 65 20 20 20 40 65 40 40 50 75 160 160 160 200 300 160 160 160 200 300 160 160 160 200 300 160 160 200 300 121 °C to 204 °C CD80AF2 Paint Ovens Heat Recovery Air Handler Intake 121 °C to 204 °C CD80AF1 Face and Bypass Low Pressure Light Industrial 121 °C to 204 °C CD80VG2 Air Handler Intake Drying Processes Balancing 1219 914 610 305 1700 2200 3800 5000 10.1 10.1 10.1 10.1 121 °C to 204 °C 2 Industrial Dampers Heavy Duty Control Dampers (continued) Damper Model CD80VG1 Standard Construction Description · 205mm x 50mm x 2mm galvanised channel frame · 13mm plated axles · 1.6mm triple vee groove galvanised blades · Concealed side linkage · Stainless steel press fit bearings · 2.64mm flanged channel frame · Airfoil 2mm galvanised blades · 19mm full length stainless steel axles · Stainless steel blade seals · BS476 Pt.20 approved · Round channel flange frame 3.25mm to 7.9mm · Steel blade with stiffeners (when required) · Adjustable full circumference blade seal · Full length solid steel axle · Shaft seals with outboard mounted ball bearings · · · · · Round channel flange frame 3.25mm to 6.3mm Steel blade with stiffeners (when required) Grease lubricated bearings mounted to frame Full length solid steel axle Full circumference blade stop Damper Width (mm) Max. System (Single Sections)* Pressure (Pa) 1219 914 610 305 620 930 1500 2050 Max. System Velocity (M/S) 10.1 10.1 10.1 10.1 Leakage With/Without Seals (CFM) 40 40 50 75 160 160 200 300 Temperature Range(°C) Applications Light Duty Ventilation Fresh Air Intake Damper Louver Combinations Fire Rated Tunnel Damper Cycle Tested Track Isolation Circular Duct Isolation Gas Vapour Isolation Bio-Labs Balancing Fume Extraction Process Piping 21 °C to 204 °C TD30AF2 1524 1219 914 610 310 1829 1524 1219 914 610 305 1829 1524 1219 914 610 305 1524 1219 914 610 305 1219 914 610 305 152 CDRI92 3000 4200 5500 6700 8000 3700 3700 3700 3900 4200 5000 3200 3200 3200 3500 3700 4200 1500 1500 2000 2000 2500 1000 1000 1000 1000 1000 20.3 20.3 20.3 20.3 20.3 35.5 35.5 35.5 35.5 35.5 35.5 30.4 30.4 30.4 30.4 30.4 30.4 20.3 20.3 25.4 30.4 30.4 12.7 12.7 12.7 20.3 20.3 20 20 20 40 60 11.5 9.5 7.5 5.5 4.0 2.0 300 225 175 140 125 75 225 175 140 125 75 56.5 42.5 28.5 14.5 7.0 -- -- -- -- -- -- -- -- -- -- -- 1375 1125 875 625 425 250 1125 875 625 425 250 175 140 125 75.0 37.5 250 °C (2 hour) Qualified to BS476 Pt. 20 2 Hour 121 °C CDR92 121 °C to 204 °C CDR82 · Round channel flange frame 3.25mm to 4.7mm · Steel blade with stiffeners (when required) · Stainless steel press fit bearings · Full length solid steel axle · Maximum size 1524mm · 1.6mm x 203mm galvanised circular channel frame up to 450mm · 2.64mm x 203mm galvanised circular channel frame 450mm and above · 2.64mm flange · Single skin 1.6mm blade · 13mm shaft to 680mm, 19mm shaft to 600mm and above · 4.16mm to 7.93mm thick channel frame · One piece 9.5mm to 19mm thick blades · Minimum 25.4mm stub axles · Adjustable ceramic tadpole seal · 260 C° to 650 C° service · · · · · 3.25mm steel circular channel frame Multiple 1.6mm blades 13mm Plated axles Open or bullet nose hub External linkage with stainless press fit bearings Odour Control Face and Bypass Incineration 121 °C to 204 °C CDRS82 Isolation Fume hoods Pharmaceutical Ventilation 121 °C CDRI95 Thermal Oxidisers High Temperature Circular Ducting Incineration Fan Inlet Circular Duct Blancing System Control Make Up Air System and Duct Pressure Pressure Relief 1524 1219 914 610 305 1321 1219 914 406 1500 2000 2000 2000 2000 Consult Ruskin Consult Ruskin IVD 11.3 15.3 20.8 33.1 71.6 30.4 30.4 30.4 30.4 30.4 -- -- -- -- -- 0.225 0.25 0.35 0.65 1.2 450 515 625 835 1410 200 175 140 125 100 121 °C to 204 °C PDR92 · Flanged channel frame · Offset blade · Grease lubricated bearings mounted outboard of frame · External counter weight · Elastomeric seal · Flanged channel frame · Stainless steel axles · Cast iron bearing · Aluminium plant finish · Aluminium · Blast Damper CD82HT High Temperature Consult Ruskin TD102 CBS8BL Consult Ruskin Consult Ruskin *Multiple section dampers are available in unlimited sizes. Leakage information based on pressure differential of 250 Pascals tested per AMCA 500. **Higher temperature ratings available consult Ruskin. Note: Alternate materials such as stainless steel construction available as an option. Nuclear Dampers available, consult Ruskin. 3 Industrial Dampers Industrial Rectangular and Circular Dampers When it comes to industrial ventilation, contractors and engineering firms around the world depend on Ruskin to provide the industry's finest product. From light operations to heavy-duty applications, we build dampers that meet the most demanding situations. Every damper is built with performance in mind and are designed to meet or exceed A.M.C.A (Air Movement Control Association) specifications. Since most industrial systems cannot be shut down for normal periodic maintenance, our products are designed to support options such as exposed linkages and outboard bearing packages. These facilitate easy maintenance while the system is operational. Ruskin works with a variety of materials, including galvanised steel, aluminium, stainless steel and fibreglass in order to match our customers exact specifications. By moulding and forming these materials, we can develop dampers to fit almost any application. CD80 Model CD80 is a versatile product range. Available in different material selections and configurations, this damper range is easily tailored to meet and exceed your system requirements. CD30 Model CD30 is available in airfoil or `v' grove blade design and is well suited for induct mounting applications. Factory installed face linkage and stainless steel pivot pins provide smooth operation, whatever the control option. 4 CDRI92 Model CDRI92 is the lowest leakage rated circular control damper without stepping up to Ruskin's bubble tight damper family. Fitted with a full circumference wiper seal as standard and outboard bearings with shaft seals, this damper can test to 2.5 Pa. PDR92 Model PDR92 circular purged damper has been specifically designed for both duct protection and additional make-up air applications. It is equipped with a counterbalanced arm and actuation override. This damper can be operated to open upon demand or by system pressure. Industrial Steel Products Industrial Steel Products CD80 Multi-Blade Airfoil The company has the technology and experience to design and manufacture models like the CD80 multi-blade airfoil damper series. A welded 3mm frame combined with 25mm thick axles and outboard bearings provide the damper with both structural integrity and performance. Perfect for applications requiring low levels of leakage at high static pressures. Features include: · Ability to withstand 11.5 kpa static Steel Inlet Vane Dampers for Class 1 and 2 Fans Steel, heavy duty inlet vane dampers are designed for fan shut off and volume control applications in medium pressure and variable air volume systems. Features include: · Sizes available in excess of 1650mm in diameter. pressure with blades closed at fan shut-off. Operate in temperatures up to 205 ºC. Double-skin airfoil type blades from 146mm to 196mm wide. Optional blade seals in EPDM, Silicone or stainless steel and jamb seals in stainless steel. Fan discharge and fan isolation. Electric or pneumatic actuation. Position sensors. Elevated temperature construction. · · · · · · · · Flange mount frame to allow bolting to fan. · Open, capped or bullet nose hub to increase performance. · Standard 3mm steel channel frame (heavier construction options available). · Standard design operation to 93 ºC (higher temperatures attainable through variations in design). CDRI 95 High Temperature, Low Leakage Damper High temperature applications are no problem for Ruskin. Where heat is a concern, dampers have been designed that offer bearings and linkages that extend from the frame to allow for both insulation and heat dissipation. Actuation may also be installed outboard by using Ruskin's exclusive high temperature couplers. Through constant testing and damper development, Ruskin has the information needed to calculate blade lengths and cross sections for practically any application. Although a particular blade may be designed for high temperature, it may not withstand extreme system pressures, that's why Ruskin performs actual inhouse testing. This allows us to select the right blade design to meet customer needs. With continual product development for the pollution control industry, Ruskin continues to surpass the competition. The CDRI95 damper is designed to operate efficiently in environments where low leakage is critical and where airflow temperatures are extreme. Functioning as a Diverter Valve that constantly redirects process exhaust gases from one chamber to another, the CDRI95 will enhance system efficiency through precise airflow control. Product features include: · Removable ceramic tadpole seal design, allows for ease of · · · · maintenance and minimises leakage at high temperatures. Designed for continuous operation up to 260 ºC and intermittent excursions to 650 ºC. Available in standard carbon steel or various grades of stainless steel. Centre pivoting blade design to enable `positive' seating. Engineered coupler for direct mounting of actuator in high temperature applications. 5 Tunnel Ventilation Products Tunnel Ventilation Products Ruskin tunnel ventilation dampers are relied upon worldwide. From London to Hong Kong to Los Angeles, Ruskin ventilation products are supplying commuters a breathe of fresh air even when they are underground. These specialised dampers provide fire protection as well as purge and smoke control during emergency conditions. With an option of galvanised steel, aluminium and stainless steel, tunnel dampers can withstand the harshest conditions, including the constantly changing environments found in most tunnels. Engineers designing tunnel ventilation safety systems, which include smoke and fire dampers, have relied on our expertise for over 40 years. They know that each damper is thoroughly checked, tested and cycled before it is delivered to site. In addition to this and to make certain each damper performs to specifications, leakage and performance requirements are verified through Ruskin's Research and Development department. TD102 Aluminium airfoil blade control dampers are well suited for tunnel ventilation projects. Damper blades are extruded from 6063T5 aluminium and finished with a 215RI anodised treatment. Axles are mechanically fixed in full length extruded blade tubes and supported on each end by externally mounted flanged bearings. A 3.5mm minimum hot dipped galvanised frame is provided with offset flanges for ease of installation. Tested and approved to 250 ºC for one hour. TD30AF2 (Fire Rated) Galvanised airfoil blades and stainless steel axles, provide the TD30AF with optimum performance for fire rated tunnel ventilation dampers. It's construction meets requirements of BS476 Pt.20, UL555S and NFPA 130 and has been tested in accordance to AMCA 500. Equipped with either pneumatic or electric spring return actuators, this damper provides excellent fail safe protection. Press fit stainless steel bearings and stainless steel blade and jamb seals, provide the corrosion protection needs of tunnel environments. 6 Accessories and Options Accessories and Options Ruskin has designed dampers to fit practically every industrial application. Guesswork is eliminated when ordering and selecting dampers, by offering many standard features, including bolt-on bearings and shaft seals. To make certain dampers meet specifications, Ruskin's in-house testing facility verifies damper leakage and performance. From manual to pneumatic type actuation, Ruskin can engineer and install the right actuation for any application. Auxiliary positioners, limit switches and other communication output signal devices are considered part of the complete package. All actuation packages are cycled and tested for accuracy and performance prior to shipment. Standard catalogue construction is called out on all Ruskin specification sheets. Pressure rating and leakage rates are based on standard construction. Industrial grade dampers are capable of being tailored to meet certain demands, such as larger flanges or non-standard bolt patterns. These options can be used on both rectangular and circular dampers. Elevated temperatures may require axle bolting or tolerance increase, which may change standard catalogue performance ratings. Axles It has been proven that the electrozinc plating that we use on our standard axles begins to flake off at approximately 230 ºC. When this occurs, the plating material can collect between the bearing and axle, causing increased friction and torque, with the possibility of the damper seizing up. To prevent this, 304 stainless steel axles are used when temperature exceeds 204 ºC. · All full length axles above 260 ºC to be bolted to the blade. · Rectangular dampers ­ Stub axles can be welded to the blade up to 450 ºC. Above this bolt blade to axle. · Circular dampers ­ As a rule, Ruskin recommends bolting the blade to the axle for all temperatures above 260 ºC continuous operation. Heatshields Heatshields are used to deflect the radiant heat coming off the damper frame, away from the actuator. However, this does not stop the heat from conducting through the axle and coupling from entering the actuator. Therefore the actuator is offset from the power axle to eliminate this problem. Excessive heat present in the actuator can damage internal seals and liquefy the necessary lubricants in the actuator, thus causing failure in actuator operation. Ruskin make every effort to eliminate the damaging effects that heat can have on actuators by supplying heat dissipating couplers. · Use heatshields at temperatures between 204 ºC ­ 260 ºC. · Above 260 ºC mount actuator offset of power axle. No heatshield is required if actuator is offset and temperature is below 426 ºC, unless specified. · Use high temperature seals in pneumatic actuators if offered by actuator manufacturer. Check with manufacturer on seals and temperature ratings. Bearings Maximum recommended temperature sintered stainless steel bearings is 815 ºC. For temperatures above this, use cast iron bearings. Graphite bearings are not recommended unless specified. Graphite bearings have a tendency to absorb moisture and crack. If graphite bearings are to be used, then stainless steel axles are required. Carbon steel axles may rust inside of the bearing causing axles to bind. Relube ball bearings packed with Dupont Krytox 240 AC grease can be bolted to frame up to 149 ºC. If mounted outboard of frame, the bearing could be used in applications up to 260 ºC. Consult Ruskin to discuss your particular needs and system requirements as industrial grade dampers are easily modified. Temperatures above the standard construction can be met by using many different methods. Electric spring return actuator. Double clevis crank arms and bolt on bearings are standard on CD80 series dampers. Certain elevated temperature applications may require the use of Ruskin's high temperature couplers reduced heat transfer into the actuator. 7 Accessories and Options Accessories and Options Typical Blade Seal Arrangements (Round Dampers) Swartwout Fibreglass Composite Products To compliment the range of Ruskin Industrial dampers, our sister company Swartwout has for over 30 years been supplying the air control industry with the most efficient and versatile range of fibreglass composite dampers. Our goal is to provide you with the finest and most cost effective solutions to your corrosive needs experienced engineering, drafting and manufacturing teams continue to satisfy the changing demands within the industry through on going research and development and the application of new technologies. Wiper Seal Tadpole Wiper Seal Metal to Metal Scissor Type Full circumference with Blade Seal Typical Blade Seal Arrangements (Rectangular Dampers) Stainless Steel Fold and Sewn Silicone Interlocking Extruded Seal Type Silicone Neoprene EPDM (Nordell) Tetraglass Ceramic Viton (Fluorocarbon) Stainless Steel Temperature 204 ºC Maximum 121 ºC Maximum 121 ºC Maximum 537 ºC Maximum 1204 ºC Maximum 204 ºC Maximum 537 ºC Maximum The illustrations below depict typical damper construction. Ruskin dampers may or may not use all the options shown. Depending on your application or system requirements you may require additional variations than those shown. Use these drawings as reference when selecting your next Ruskin Industrial dampers. Non-Powered Axle Web Mounting Holes Flange Shaft Seal (Packing gland) Outboard Bearing Bracket Plate Blade Seal Blade Retaining Ring Fasteners Outboard Bearing Extended Shaft (Axle) Corrosion Resistant Products Designed for Extended Service Life In harshly corrosive environments, engineering, material selection and manufacturing of appropriate ventilation system products are critical. Fibreglass composite dampers are respected industry-wide for workmanship, performance and long service life, fulfiling your ventilation product requirements for corrosive applications. So why choose fibreglass composite products? Composites are strong, durable and lightweight · Dent, crack and break resistant. · Resistant to harsh climates, salt spray and corrosive chemicals. · Corrosion liners standard on all products. · Constructed from fibreglassreinforced plastic (FRP) made with exceptionally strong vinyl ester resin. Composites offer &quot;built-in&quot; safety · Fire retardant. · Electrically non-conductive. Composites provide low operating costs · Last many years longer than the best stainless steel units, yet cost less. · Thermally non-conductive to reduce energy costs. Typical Shaft Seal Arrangements Stuffing Box Shaft Seal Seal Retaining Blade Stiffeners Blade Coupler Ring (When required) Stop Pin Actuator Coupler Web Mounting Holes Flange Shaft Seal (Packing gland) Outboard Bearing Mounting Plate Outboard Bearing (Sleeve in cast housing std, ball bearing optional) Pump Type Shaft Seal Packing Types Temperature Extended Shaft (Axle) Crank Lever For Motor Operation Jamb Seal Side Linkage Non-Asbestos and Silicone free Fibre Infused TFE 232 ºC Chrysotile Asbestos Graphite and Asbestos Core with Inconel Wire 537 ºC 100% Graphite 1371 ºC Blade Edge Seal Airfoil Blade Stainless Steel Linkage Pins Double Clevis Crank Arm 8 Fibreglass Composite Products Fibreglass Composite Products 912 and 914 Fibre-Aire Circular Control Dampers Fibre-Aire circular control dampers are designed specifically for use in corrosive environments such as: · Wastewater Treatment Plants · Pharmaceutical Facilities · Pulp and Paper Mills Features include: · Accurate control of airflow through round ductwork. · Flange mount channel frame. · Single piece blade with 3 frame style options to meet your specific requirements. · Sizes from 100mm to 1800mm in diameter. · Type 912 designed to withstand pressures up to 2500 pa. · Type 914 designed to withstand pressures up to 7500 pa. 851FG Fibre-Aire Inlet Vane Damper Fibre-Aire inlet vane dampers are designed for use with fibreglass fans in variable air volume systems. Units can be manually set, electrically or pneumatically actuated to achieve required performance. Features include: · Flange mount frame to allow bolting to fan. · Capped or bullet nose hub to increase performance. · Sizes from 300mm to 1800mm in diameter. · Blades coated using a resin transfer moulding technique (RTM) to ensure optimised corrosion resistance in the airstream. SPVC12 PVC Circular Damper Circular polyvinyl chloride control damper offers an effective and economical material resistant to most corrosive gases. Able to withstand temperatures to 82 ºC, the SPVC 12 is ideal for a wide range of industrial applications: Features include: · Material confirms to ANSI/ASTM specification D-1784-81PVC, Type 1. · Self-lubricating, ultra high molecular- weight polyethylene bearings. · Stainless steel set collar. · Sizes from 150mm to 400mm in diameter. · Ideally suited for Fume Hood systems. Options include: · Electric or pneumatic operates. · Flange mounted design. · Extended frame lengths for a variety of applications. 1108AF Multi-Blade Control Damper Model 1108AF multi-blade control damper offers low leakage and non corrosive components to provide the best fibreglass damper on the market. Uses include: · Wastewater Treatment Facilities · High Purity Electronic Chip Production · Fertiliser/Compost Production Facilities Features include: · Tooled in blade seal pockets for a variety of blade seal materials. · Flange mount or in-duct frame styles. · All vinyl ester construction. · High strength airfoil blade design. · Teflon bearings. 9 Industrial Dampers Custom Products Developments Developing products which meet the ever changing demands of the air control industry while providing the highest level of customer service. We recognise the uniqueness of each customers requirements. This is what drives us to continually research product improvements and to incorporate new technologises. We rely on versatile manufacturing capabilities to develop and manufacture customer specific products. Development of products utilising Fibreglass Reinforced Plastic is an example of our commitment to our customers. Incorporating this technology has led to the development of the FRP2000 Slide Gate and to the 426AF Backdraft damper. Both these dampers are manufactured to withstand the severely corrosive gases present in electronic chip production. FRP 2000 Slide Gate Model FRP 2000 Slide Gate Positive Shut Off Damper. This damper is laminated entirely of fire retardant, vinyl ester resin and is suited for corrosive environments. Available in manual or automatic operation and can be serviced without removal from the system. Seal package can be replaced from one of three sides. Options available: · Rectangular or circular mounting flanges. · Various types of seal materials. · Manual or motorised operation. 426AF Backdraft Damper Utilising a hollow airfoil design, the model 426AF provides high strength and low pressures drop advantages. It incorporates a tooled-in blade edge seal pocket for various types of elasto-meric materials when in conjunction with either 316 stainless steel or polycarbonate side seals. Features include: · Fully engineered backdraft damper. · Low leak minimal pressure drop airfoil blade design. · Static pressure up to 3500 pa. · Standard stainless steel counter balance side linkage. · Silicone, viton and EPDM blade seal material availability. 10 Corrosion-Resistant Materials of Construction KEY: R ­ RECOMMENDED CHEMICAL FUMES (200° MAX) FIBREGLASS STAINLESS REINFORCED STEEL PLASTIC 304 316 NR ­ NOT RECOMMENDED CHEMICAL FUMES (200° MAX) FIBREGLASS STAINLESS REINFORCED STEEL PLASTIC 304 316 CS ­ CONSULT RUSKIN FIBREGLASS STAINLESS REINFORCED STEEL PLASTIC 304 316 CHEMICAL FUMES (200° MAX) FIBREGLASS STAINLESS REINFORCED STEEL PLASTIC 304 316 CHEMICAL FUMES (200° MAX) FIBREGLASS STAINLESS REINFORCED STEEL PLASTIC 304 316 CHEMICAL FUMES (200° MAX) Acetaldehyde Acetic Acid 0-25% Acetic Acid 25-50% Acetic Anhydride Acetone Acrylonitrile Alcohol, Butyl Alcohol, Ethyl 10% Alcohol, Ethyl 100% Alcohol, Ispropyl 10% NR R R NR NR NR R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R R Chlorine Dry Gas Chlorine , Wet Gas Chlorine, Liquid Chlorine, Water Chloroascetic Acid 0-50% Chlorobenzene Chloroform Chloriosulfonic Acid Chlromic Acid 20% Chlromic Acid 30% Chromium Sulfate Citric Acid Coconut Oil Copper Chloride Copper Cyanide R R NR R R NR R NR NR R(100°) R(110°) NR NR NR NR NR R R NR R R NR NR NR NR R R NR R R R R R R R CS CS R R R R NR NR R R NR NR R R R R Glycerine R Glycol, Ethylene R Glycol, Propylene R Glycolic Acid R Gold Plating Solution: R (63% Potassium Ferrocyanide 2% Potassium Gold Cyanide 8% Sodium Cyanide) Heptane Hexane Hexylene Glycol Hot Stack Gasses Hydraulic Fluid Hydrobromic Acid 0-25% Hydrochloric Acid 0-37% Hydrocyanic Acid Hydrofluoric Acid 10% Hydrofluosillcic Acid Hydrogen Bromide, Wet Gas Hydrogen Chloride, Dry Gas Hydrogen Chloride, Wet Gas Hydrogen Peroxide Hydrogen Sulfide Dry Hydrogen Sulfide, Aqueous Hydrogen Fluoride, Vapour Hydrosulfite Bleach Hypochlorous Acid 0-10% Iron & Steel Cleaning Bath: (9% Hydrochloric 23% Sulfuric) Isopropyl Amine Isopropyl Palmitate Jet Fuel Kerosene Lactic Acid Lauryl Chloride Lauric Acid Lead Acetate Lead Nitrate Lead Plating Solution: (8% Fluorboric Acid 4% Boric Acid) Levullnic Acid Linseed Oil Lithium Bromide Lithium Sulfate Magnesium Bisulfite Magnesium Carbonate Magnesium Chloride Magnesium Hydroxide Magnesium Sulfate Meleic Acid Mercuric Chloride Mercurous Chloride Methylene Chloride Methyl Ethyl Ketone Methyl Isobutyl Carbitol Methanol (see Alcohol) Methyl Isobutyl Ketone Methyl Styrene Mineral Oils Molybdenum Disulfide Monochloro Acetic Acid Monoethynolamine Motor Oil Myristic Acid Naptha Napthalene Nickel Chloride Nickel Nitrate Nickel Plating: (8% Lead 8% Flourboric Acid 4% Boric Acid) (11% Nickel Sulfate 2% Ammonium Chloride 1% Boric Acid) (44% Nickel Sulfate 4% Ammonium Chloride 4% Boric Acid) R R R ­ R R R R R R R R R R R R R R R R R R R R NR R R R R R Nickel Sulfate Nitric Acid 0-5% Nitric Acid 20% Nitric Acid Fumes Nitrobenzene Octanoic Acid Oil, Sour Crude Oil, Sweet Crude Oleic Acid R R R R R R R R R R R R Sodium Hydroxide 0-5% Sodium Hydroxide 5-25% Sodium Hydroxide 50% Sodium Hydrosulfide Sodium Hypochlorite Sodium Lauryl Sulfate Sodium Mono-Phosphates Sodium Nitrate Sodium Silicate Sodium Sulfate Sodium Sulfide Sodium Sulfite Sodium Tetra Borate Sodium Thiocyanate Sodium Thiosulfate Sodium Tripolyphosphate Sodium Xylene Sulfonate Sorbitol Solutions Sour Crude Oil Soya Oil Stannic Chloride Stannous Chloride Stearic Acid Styrene Sugar, Beet & Candy Liquor Sugar, Sucrose Sulfamic Acid Sulfanilic Acid Sulfated Detergents Sulfur Dioxide, Dry or Wet Sulfur Trioxide/Air (76% P205) Tall Oil Tannic Acid Tartaric Acid Thionyl Cyloride R R R R R R R R R R R R R R R R R R R R R R R NR R R R R R R R R R R R R NR NR R R CS CS CS CS R R R R R R R R R R CS CS CS CS R R CS CS CS R CS CS CS CS R CS Alcohol, Ispropyl 100% R Alcohol, Methyl 10% R Alcohol, Methyl 100% NR Alcohol, Methyl Isobutyl R Alcohol, Secondary Butyl R Aluminium Aluminium Chloride Aluminium Hydroxide 5% Aluminium Nitrate Aluminium Potassium Sulfate Ammonia, Aqueous 0-10% Ammonia, Gas Ammonium Bicarbonate Ammonium Bicsulfite Ammonium Carbonate Ammonium Citrate Ammonium Fluoride Ammonium Hydroxide 5% Ammonium Hydroxide 10% Ammonium Hydroxide 20% Ammonium Nitrate Ammonium Persulfate Ammonium Phosphate Ammonium Sulfate Arsenious Acid O-Benzoyl Benzoic Acid Barium Acetate Barium Carbonate Barium Chloride Barium Hydroxide Barium Sulfate Barium Sulfide Beer Benzene 5% Benzen in Kerosene R R R R R R R R R R R R R R R R R R R R R R R R R R R R CS CS CS CS CS CS NR NR NR NR R R NR NR NR R CS CS R R R R R R R R NR R R R CS CS CS CS CS CS NR R R R CS CS R NR NR R R R R R R NR R NR NR R R R R NR R R R R R R R R R R R R R NR NR R R R R RR R R R NR R R R R R R Copper Fluoride R Copper Nitrate R Copper Plating Solution: R (Copper Cyanide 10.5% Copper, 14% Copper Cyanide 6% Rochelle Salts) Copper Brite Plating: R (Caustic Cyanide) Copper Plating Solution: R (45% Copper Fluoroborate 19% Copper Sulfate 8% Sulfuric Acid) Copper Matte Dipping Bath: (30% Ferric Chloride 19% Hydrachloric) Copper Pickling Bath: (10% Ferric Sulfate 10% Sulfuric Acid) Copper Sulfate Corn Oil Corn Starch ­ Slurry Corn Sugar Cottonseed Oil Crude Oil, Sour Crude Oil, Sweet Cyclohexane Detergents, Sulfonated Di-Ammonium Phosphate Dibromophenol Dibutyl Ether Dichloro Benzene Dichloroethylene Diesel Fuel Diethylene Glycol Dimethyl Phthalate Dicoctyl Phthalate Dipropylene Glycol Dodecyl Alcohol Esters, Fatty Acids Ethyl Acetate Ethyl Benzene Ethyl Ether Ethylene Glycol Ethylene Dichloride Fatty Acids Ferric Chloride Ferric Nitrate Ferric Sulfate Ferrous Chloride Ferrous Nitrate Ferrous Sulfate 8-8-8 Fertiliser Fertiliser (Urea Ammonium Nitrate) Flue Gas Fluoboric Acid Fluosillsic Acid 0-20% Formaldehyde Formic Acid Fuel Oil Gas, Natural Gasoline, Auto Gasoline, Aviation Gasoline, Ethyl Gasoline, Sour Gluconic Acid Glucose R Oleum (Fuming Sulfuric) NR R R Olive Oil R CS CS Oxalic Acid R NR R Peroxide Bleach R CS CS (2% Sodium Peroxide 96% 0.25% Epsom Salts 5% Sodium Silicate 42°BE 14% Sulfuric Acid 66°BE) Phenol NR R R Phenol Sulfonic Acid Phosphoric Acid Phosphoric Acid Fumes Phoshorus Pentoxide Phorphorus Trrichloride Phthalic Acid Pickling Acids (Sulfuric & Hydrochloric) Picric Acid, Alcoholic Polyvinyl Acetate Latex Polyvinyl Alcohol NR CS CS R NR R R CS CS R R R NR R R R R R R R R R CS CS R R R R CS CS CS CS R R R R R R R R R R R R R R R R R R R R R R NR NR CS CS NR NR NR R R R CS CS CS CS CS NR CS NR NR CS NR CS NR R CS CS R CS CS R R CS CS R R NR R RR R R R R R R R R R R NR R NR NR R R R R R R NR R CS CS CS CS R R R R R R R R R R CS CS CS CS CS CS NR R R R R R R R R R R R R R R R R R R R R R CS CS CS CS R R R R R R NR NR R R R R R R R R Polyvinyl Chloride Latex w/35 (Parts DOP) R Potassium Aluminium Sulfate R Potassium Bicarbonate R Potassium Bromide R Potassium Carbonate R Potassium Chloride Potassium Dichromate Potassium Ferricyanide Potassium Hydroxide R R R R R CS CS R R R R R R R R R NR NR NR R R R R CS CS R R R NR R R R RR R R R R NR R R R R R Benzen Sulfonic Acid R Benzoic Acid R Benzyl Alcohol R Benzyl Chloride NR Brass Plating Solution: R (3% Copper Cyanide 6% Sodium Cyanide 1% Zinc Cyanide 3% Sodium Carbonate) Butyl Acetate Butyric Acid 0-150% Butylene Glycol Cadmium Chloride Cadmium Cyanide Plating Solution: (3% Cadmium Oxide 10% Sodium Cyanide 1% Caustic Soda) Cadmium Bisulfite Calcium Carbonate Calcium Chlorate Calcium Chloride Calcium Hydroxide Calcium Hypochlorite Calcium Nitrate Calcium Sulfate Calcium Sulfite Caprylic Acid Carbon Dioxide Carbon Disulfide Carbon Monoxide Carbon Tetrachloride Carbonic Acid Castor oil Carbon Methyl Cellulose Chlorinated Wax Chlorine Dioxide Air Chlorine Dioxide, Wet Gas R R R R R R R R R R CS CS R R NR R CS CS CS CS NR NR R R R R R R NR NR Potassium Nitrate R R Potassium Permanganate R R Potassium Persulfate R NR Potassium Sulfate R R Propionic Acid 1-50% R NR 50-100% NR NR Propylene Pulp Paper Mill Effluent Pyridine Salicylic Acid Sebacic Acid R R R R CS CS NR R R R R R R CS CS CS CS R R Tin Plating: R NR R (18% Stannous Flouroborate 7% Tin 9% Fluoroboric Acid 2% Boric Acid) Toluene NR R R Toluene Solfonic Acid R CS CS Transformer Oils: NR R R (Mineral Oil Types Chloro-Phenyl Types) Trichlor Acetic Acid R NR NR Trichlorethylene Trichlorophenol Tricresyl Phosphate Tridecylbenzene Sulfonate STrisodium Phosphate Turpentine Urea Vegetable Oils Vinegar Vinyl Acetate NR R R NR CS CS R R R R CS CS R NR NR R R R R NR R R R R R R R R R R NR NR R R(180°) R R R CS R NR NR NR NR R R R R R R R R CS R R R R R R R R R R CS CS R CS CS R R R NR R R NR NR R NR R R R R R NR R R R R R R NR NR R R R R R R R R R R R R R R R R R R R R R R R R R NR NR NR R R R CS CS NR R R CS CS CS NR R R CS R NR NR R NR NR NR R R NR NR NR NR R NR R R R NR R R NR CS CS R R R R CS CS NR CS CS NR R R R R R R NR NR R R R R R R R R R R R R R R R Selenlus Acid R Silver Nitrate R Silver Plating Solution: (4% Silver Cyanide 7% Potassium Cyanide 5% Sodium Cyanide 2% Potassium Carbonate) Soaps R Sodium Acetate R Sodium Benzoate Sodium Bircarbonate Sodium Bifluoride Sodium Bisulfate Sodium Bisulfite Sodium Bromate Sodium Bromide Sodium Carbonate 0-25% Sodium Chlorate Sodium Chloride Sodium Chlorite Sodium Chromate Sodium Cyanide Sodium Dichromate Sodium Di-Phosphate R R R R R R R R R R R R R R R NR R R R R NR NR R R R R CS CS R R(160°)R(160°) R R R R R R R R R R R R R CS CS R R R R R R R R R R NR R R R R R CS CS NR R NR R NR R CS CS CS CS Water Deionised Demineralised Distilled Fresh Salt Sea White Liquor (Pulp Mill) Xylene Zinc Chlorate Zinc Nitrate R R R R R R R R R R R R R R R R R R R R R NR R R R NR NR R R R NR NR R R R R CS CS R R R R R R R R R R R R R R NR NR R R R R R R R R CS CS R R CS CS R R R R(80°) R R CS CS R CS CS R NR R R NR N Sodium Ferricyanide R Sodium Ferrocyanide R Sodium Fluoride R Sodium Fluoro Silicate R Sodium Hexametaphosphates R Zinc Plating Solution: R NR NR (9% Zinc Cyanide 4% Sodium Cyanide 9% Sodium Hydroxide) (49% Zinc Fluoroborate 5% Ammonium Chloride 6% Ammonium Fluoroborate) Zinc Sulfate R R R Listings above are for reference only. For specific applications contact Ruskin Air Management. 11 Industrial and Tunnel Ventilation Dampers RUSKIN Quality System Certificate No 017 Assessed to ISO 9002 BS EN ISO 9002 : 1994 Certificate No. FM1611 Ruskin Air Management Ltd. Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.co.uk");sQ1[40]=new Array("http://www.actionair.co.uk/pdf/hydropac.pdf","2744 Hydropac_April_03.qxd","","June 2003 Hydropac Hydropac Waterside Control Fan Coil Units For Horizontal and Vertical Applications Features Flush panel extra rigid construction. Low noise levels. Eleven speed transformer. Full acoustic and thermal insulation. Various filter options. All types of controls available, fitted and wired. Outputs available up to 6.4 kW cooling and 6.9 kW heating. Horizontal Hydropac PHW173 Illustrated Designed and Built in Britain Patent Nos. Pending Hydropac PHW230 and PHW170 Series Hydropac (Series PHW) Actionair Hydropac horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure hot water heating medium. Temperature control is by means of modulating 4-port diver ting valves on heating and cooling, operated by stand alone or BMS controller with room or return air temperature sensor. Designated `PHW', the series consists of standard 230mm (PHW230) deep and slimline 170mm (PHW170) deep versions. Robust construction 1.6mm top panel and fan deck, all other panels 1.2mm galvanised steel. High quality EBM Ziehl external rotor motor fans. Interchangeable spun steel spigots and insulated blanking plates. Fully insulated with Class `O' open cell thermal and acoustic foam. Quick installation with recessed reinforced slotted mounting points. 2 Hydropac Detail Construction Easy filter removal with three filter options: EU3 Filter Media. EU2 Metal Mesh. Commissioning filter (EU2 Metal Mesh + Media Filter.) High performance coils with vents and drains. Circuited to provide full contra flow. Pipe support plate. Insulated removable powder coated drain tray, with connection options. Illuminated on/off switch with 3 speed fan and fine adjustment switches. Giving 9 speeds on exterior of units. Enclosure incorporating 11 speed transformer with 24 volt output for FCU controller. 3 Hydropac PHW 230 Series PHW 230 Series Waterside control 230mm deep ceiling void mounted chassis unit 11 °C min air off ChW 6°C flow, 11°C return Model Speed Setting 2 3 PHW231 4 5 6 2 3 PHW232 4 5 6 2 3 PHW232X 4 5 6 2 3 PHW233 4 5 6 2 3 PHW234 4 5 6 2 3 PHW234X 4 5 6 2 3 PHW235 4 5 6 2 3 PHW235X 4 5 6 Airflow (I/s) 75 85 100 115 125 110 125 150 175 185 90 120 160 200 230 175 200 240 280 305 170 210 255 300 330 195 235 290 340 375 185 225 280 340 375 230 275 340 405 445 Sensible Cooling (Watts) 905 990 1120 1240 1325 1530 1710 2020 2320 2400 1310 1620 2110 2690 3050 2450 2800 3360 3920 4270 2660 3200 3650 4000 4200 2800 3350 4000 4300 4500 2650 3100 4000 4800 5300 3300 3900 4800 5400 5600 Total Cooling (Watts) 1040 1125 1255 1385 1475 1890 2080 2430 2800 2890 1640 2000 2540 3240 3720 3020 3460 4150 4850 5270 3460 4160 4950 5740 6050 3400 4050 4770 4960 5100 3210 3710 4830 5800 6400 4010 4720 5800 6370 6450 14 °C min air off ChW 10°C flow,14°C return Sensible/Total Cooling (Watts) 730 790 880 980 1050 1180 1300 1520 1730 1780 1010 1240 1570 1990 2260 1830 2070 2460 2870 3110 1970 2360 2820 3280 3530 2150 2610 3180 3680 4010 2000 2400 3010 3640 3920 2550 2990 3640 4290 4670 Thermal Performance Data LPHW 82°C flow 72°C return Heating (Watts) 1050 1130 1240 1345 1415 2150 2290 2500 2700 2800 1960 2220 2500 2900 3200 3200 3400 3800 4100 4400 3810 4200 4610 5010 5300 4110 4410 4910 5410 5700 4510 4910 5410 5910 6310 4910 5410 5910 6510 6910 Fan Input (Watts) 33 47 57 66 78 50 70 90 110 144 60 75 114 125 160 110 140 180 220 270 110 140 220 275 370 165 200 240 300 356 165 200 290 365 495 227 288 364 440 556 N.R. Guide* 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 The Fan Coil selections are based on the following entering air conditions: Cooling: Summer On-coil air 23 °C Dry Bulb, 16 °C Wet Bulb. Max Coil Pd = 20kPa Heating: Winter On-coil air temperature 20 °C Dry Bulb. Max Coil Pd = 10kPa General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. Please refer to our Fan Coil Technical Department for alternative conditions. * see page 7 for NR Predictor. 4 Hydropac PHW 230 Series PHW 230 Series Dimensions Model PHW 231 PHW 232/2X PHW 233 PHW 234/4X PHW 235/5X Dim A 380 730 1080 1430 1780 Dim B 350 700 1050 1400 1750 Weights 25kg 35kg 50kg 70kg 90kg Spigots 1-4-7 1-2-6-7 1-2-4-6-7 1-2-3-5-6-7 1-2-3-4-5-6-7 5 Hydropac PHW 170 Series PHW 170 Series Waterside control 170mm deep ceiling void mounted chassis unit 11 °C min air off 14 °C min air off ChW 6°C flow, 11°C return ChW 10°C flow,14°C return Sensible Total Sensible/Total Cooling Cooling Cooling (Watts) (Watts) (Watts) 1192 1385 1532 1701 1928 1893 2187 2380 2592 2941 2237 2573 2774 3035 3399 2825 3228 3429 3696 4002 1407 1602 1786 1673 2225 2225 2257 2751 3011 3403 2738 3136 3374 3680 4092 3427 3905 4145 4481 4808 978 1120 1255 1394 1579 1550 1790 1932 2123 2410 1675 1916 2067 2268 2557 2127 2423 2577 2786 3031 Model Speed Setting 2 3 PHW172 4 5 6 2 3 PHW173 4 5 6 2 3 PHW174 4 5 6 2 3 PHW175 4 5 6 Airflow (I/s) 90 105 120 135 155 145 170 185 205 235 155 180 195 215 245 200 230 245 265 290 Thermal Performance Data LPHW 82°C flow 72°C return Heating (Watts) 1982 2187 2357 2525 2742 3081 3390 3355 3772 4092 3655 4026 4246 4519 4861 4740 5191 5415 5706 5997 Fan Input (Watts) 40 50 62 74 89 80 101 133 160 189 80 101 133 160 189 113 143 187 224 267 N.R. Guide* 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 The Fan Coil selections are based on the following entering air conditions: Cooling: Summer On-coil air 23 °C Dry Bulb, 16 °C Wet Bulb. Max Coil Pd = 20kPa Heating: Winter On-coil air temperature 20 °C Dry Bulb. Max Coil Pd = 10kPa General: External Resistance 30Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. Please refer to our Fan Coil Technical Department for alternative conditions. * see page 7 for NR Predictor. Dimensions Unit PHW 172 PHW 173 PHW 174 PHW 175 Dim A 730 1080 1430 1780 Dim B 700 1050 1400 1750 Dim C 225 267 287 300 Weight 32kg 45kg 65kg 85kg SPIGOT OPTIONS 1-2-4-7-8 1-2-3-6-7-8 1-2-3-4-6-7-8 1-2-3-4-5-6-7-8 6 Hydropac PHW 230 / 170 Series Acoustic Performance Data Typical Horizontal Fan Coil Unit Arrangement Fresh air supply duct. Fan coil unit. Minimum 1 metre length Sonodec 25 acoustic flex. Diffuser plenum. Building structure. Wall/glazing. Return air grille/diffuser (not positioned directly below unit intakes). T Bar grid false ceiling with either 10mm thick fibre board tiles or insulated metal pan tiles. Internal room. * Notes on `NR' predictions `NR' predictions quoted are based upon extensive acoustic independent tests to the above arrangement and are intended as a guide to levels which can be expected. The following qualifications must apply:Units must be mounted correctly, using rubber washers, onto a solid structure. The units should be mounted into a false ceiling of not less than 300mm deep, constructed of a standard `T' bar grid with 10mm thick fibre board tiles or insulated metal pan tiles. Rooms of open plan or partitioned design should be furnished, carpeted and have no more than 20% glass area with no highly reflective surfaces such as ceramic tiles etc. Where a single unit is serving a room the dimensions should be based upon a cooling load of 120w/sq.m e.g a unit giving 1.2kW total cooling output should be serving a room with a floor area of not less than 10sq.m. In an open plan area units should be mounted at a minimum of 4.5m centres and no closer than 1.5m from a corner. Return air grilles should not be positioned directly below unit intakes. At least 1m of acoustic flexible ducting (Sonodec 25 or similar) is used on each spigot outlet. A maximum air velocity of 3.0m/s per outlet spigot to achieve NR35. The above should give the predicted Lp at 1.5m from the nearest diffuser. For detailed acoustic data of Inlet/Casing Radiated and Discharge Sound Power Levels, please refer to Actionair Sales Office. 7 Hydropac PVW230 Series Detail Constru Hydropac (Series PVW) Actionair vertical chassis and cased wall mounted fan coils are waterside control, suitable for free-blow, applications or vertical ducted arrangements operating up to 60 Pa external resistance, using chilled water cooling medium and low pressure hot water medium. Temperature control is by means of modulating 4-port diver ting valves on heating and cooling. Designated PVW the series consists of five models 230mm deep, with six non-cased/cased variations. Protected control enclosure. Discharge spigot can be vertical or horizontal. Slide out filters. EBM Ziehl external rotor motor fans. Condensate removal pump when used. 8 Removable front access. Hydropac ction PVW 230 Cases Options and Mounting Arrangements Option 1. Low level mounting with front angled grille outlet. Option 2. Low level mounting with front angled grille outlet and front face grille inlet. Option 3. High level mounting as per option 2 but with protection panel on underside . Option 4. High level mounting with front grille outlet and underside grille inlet. 9 Hydropac Series PVW 230 PVW 230 Series 230mm deep vertical wall mounted chassis / cased units 11 °C min air off Model Speed Setting 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 2 3 4 5 6 Airflow (I/s) 40 50 60 60 70 90 100 110 120 130 115 140 160 180 215 140 160 200 220 240 185 225 250 275 320 Sensible Cooling (Watts) 419 489 557 557 617 888 957 1025 1093 1162 1292 1525 1715 1905 2229 1530 1702 2057 2241 2428 1925 2213 2472 2697 3117 Total Cooling (Watts) 463 534 570 605 668 971 1041 1113 1185 1259 1446 1695 1898 2105 2455 1701 1881 2263 2463 2866 2122 2428 2706 2949 3404 14 °C min air off Sensible/Total Cooling (Watts) 350 380 400 410 430 778 840 903 968 1034 1017 1170 1296 1428 1666 1246 1363 1608 1738 1873 1578 1784 1970 2133 2449 ChW 6°C flow, 11°C return ChW 10°C flow, 14°C return Thermal Performance Data LPHW 82°C flow 72°C return Heating (Watts) 704 829 883 934 1017 1737 1851 1964 2077 2188 2458 2757 2992 3224 3604 3066 3303 3767 3995 4220 4018 4436 4788 5078 5594 Fan Input (Watts) 17 20 22 25 28 32 36 40 45 49 50 60 65 75 90 58 63 80 90 100 85 120 150 165 185 N.R. Guide* 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 30 32 35 38 40 . PVW231 PVW232 PVW233 PVW234 PVW235 The Fan Coil selections are based on the following entering air conditions: Heating: Cooling: Winter On-coil air temperature Summer On-coil air 23 °C Dry Bulb, 20 °C Dry Bulb. 16 °C Wet Bulb. Max Coil Pd = 10kPa Max Coil Pd = 20kPa General: External Resistance 10Pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. * see page 11 for NR Predictor. Chassis Dimensions Unit PVW 231 PVW 232 PVW 233 PVW 234 PVW 235 Dim A 785 1035 1385 1735 2085 Dim B 310 660 1010 1360 1710 Weight 30kg 43kg 62kg 86kg 110kg 10 Hydropac Series PVW 230 PVW 230 Series * Notes on `NR' predictions `NR' predictions are based upon extensive acoustic independent tests and are intended as a guide to levels which can be expected, when measured at 2.0m. The following qualifications apply:Units must be mounted correctly, using fixing points provided onto a flat, solid surface, such as concrete or brick wall in such a way that they are not subjected to undue stress and are checked for accuracy of horizontal levelling. Rooms of open plan or partitioned design should be furnished, carpeted and have no more than 20% glass area with no highly reflective surfaces such as ceramic tiles etc. Where a single unit is serving a room the dimensions should be based upon a cooling load of 120w/sq.m e.g a unit giving 1.2kW total cooling output should be serving a room with a floor area of not less than 10sq.m. In an open plan area units should be mounted at a minimum of 3m centres and no closer than 1.5m from a corner. Units installed in accordance with the above should give the predicted N.R. level when measured at a distance of 2.0m from any surrounding flat surface. For detailed acoustic data of Radiated Sound Power Levels, please refer to Technical Sales Office. Option 2 and 3 Case Option 1 Case Case Dimensional Data Option 4 Case Unit PVW 231 PVW 232 PVW 233 PVW 234 PVW 235 Dim A 815 1065 1415 1785 2115 Dim B 310 660 1010 1360 1710 Weight 35kg 50kg 70kg 95kg 120kg 11 Actionair w w w . a c t i o n a i r. c o . u k Also available NEW Technical Support Actionair provide quality products backed by a dedicated team committed to providing the very best in customer service. Specialist response from the Actionair Sales Team, administrative response from the Computerised Sales Office and product maintenance from the Team of Experienced Service Engineers, who understand fully the needs of the industry. Actionair Products For information on our comprehensive range of Fire, Smoke and Air Control Dampers, as well as Application, Technical and Pricing Advice, please refer to the Actionair Sales Office. Environpac EMC Motor Technology 40% Less Motor Energy 1/3 Less Fan Heat Constant Volume NEW Systempac Fancoil, Ductwork and Diffuser Package Fast Track Delivery Fully Acoustically Tested Sample Design Selection Aeropac Airside Control Fancoil 230mm Deep Horizontal Mounted High Energy Efficiency NO COMPROMISE Quality System Certificate No 017 Assessed to ISO
    9001: 2008 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited The information contained herein is subject to change without notice due to continuing research and development. PRODUCED BY GRAPHIC PARTNERSHIP 01227 280877");sQ1[41]=new Array("http://www.actionair.co.uk/Hydropac EC.html","Actionair Hydropac EC Series","Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke     control  and waterside control fan coil units through the pursuit of excellence.","Home Products Actionair Hydropac EC - Energy efficient fan coils using EC fan technology Flush panel extra rigid construction. Low noise levels. 0-10V Fan Input Full acoustic and thermal insulation. Minimal fan heat. Various filter options. Outputs available up to 6.4kW cooling and 6.9kW heating. Constant volume option.   Actionair Hydropac EC Energy efficient fan coils using EC fan technology Actionair Hydropac EC horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure Temperature control is by means of modulating 4 &#8211; port diverting valves on heating and cooling, operated via stand alone or BMS temperature controller and room or return air sensor. Designated &#8216;EHW&#8217;, the range consists of six size options at 230mm deep. For more information including dimensional and installation data please view the Hydropac EC Datasheet  Construction Environpac Catalogue Specification for Hydropac EC Chassis Manufactured from 1.2mm galvanised sheet steel with 1.6mm fan decks and back plates. The chassis shall incorporate recessed, slotted mounting points for drop-rods. An integral acoustically lined discharge plenum fitted with spun steel spigots and insulated blanking plates. Access Access to fans shall be via an insulated bottom panel with keyhole slots. Insulation 100Kg/m3 density, class &#8216;O&#8217; CFC and HFC free open cell foam shall be utilised for both thermal acoustic insulation. Fans/Motors Fan/motor shall be LOW ENERGY EC (Electonically commutated) external rotor ,forward curved centrifugal type, with high efficiency, low noise multiblade galvanised sheet steel impellers. Electrical supply shall be 230V 1ph 50Hz. Meets current EMC emissions and harmonic regulations. Speed Control Speed control shall be by means of a stepless potentiometer or 0-10v input via BMS. On/off control to fans shall be by means of a panel mounted illuminated two position switch. Coils Coil matrix blocks shall be copper with aluminium fins. Fitted with vents and drains as standard Condensate Tray Condensate trays shall be synthetically treated, galvanised sheet steel, foam insulated. A positive fall to drain shall be provided with 3/4&quot; B.S.P. female bottom connection. Filters Filters shall be washable EU3, continuous filament media. Please click here to copy the specification to your clipboard ready to paste into your project specification. Click to see Actionair Fancoil i-drop library and drop drawings into your Autodesk application with &#8220;Download idrop indicator&#8221; To learn more about i-drop technology click here.  (View Datasheet) All Catalogues    Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[42]=new Array("http://www.actionair.co.uk/syspack.html","Actionair Systempac Fan Coil Unit / Acoustic Flex / Diffuser System Package","Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke     control  and waterside control fan coil units through the pursuit of excellence.","Home Products Actionair Systempac - Fan coil unit / acoustic flex / diffuser system package Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box / Diffusers. Choice of Linear Slot Diffusers or 4 Way Throw Louvred-Faced Diffusers. Available in three thermal outputs 2kW / 3kW / 4kW sensible cooling and heating. Fully acoustically and thermally tested. Quick and simple design selection. Customer friendly installation and commissioning. Competitive priced solutions with fastrack delivery.   Actionair Systempac Fan coil unit / acoustic flex / diffuser system package Actionair Hydropac horizontal ceiling void mounted type fan coils are waterside control, suitable for operation against moderate duct resistances, using chilled water cooling medium and low pressure hot water. Temperature control is by means of modulating 4 &#8211; port diverting valves on heating and cooling, operated via stand alone temperature controller. For more information including dimensional and installation data please view the 8 page Systempac Catalogue  Construction Catalogue Fan Coil Unit Waterside Control 230mm deep horizontal draw through chassis type Fan Coil Units. Chassis constructed from 1.2mm galvanised sheet steel, with 1.6mm fan deck and back plates. The flush external finish prevents exposure to bare edges and incorporates recessed, reinforced slotted mounting points for ease of installation. Access to fans/motors is via an insulated bottom panel with keyslots for accurate positioning and easy removal.  (View Catalogue) All Catalogues  A package from both Actionair and Air Diffusion Specification Chassis Manufactured from 1.2mm galvanised sheet steel with 1.6mm fan decks and back plates. The chassis shall incorporate recessed, slotted mounting points for drop-rods. An integral acoustically lined discharge plenum fitted with spun steel spigots and insulated blanking plates. Access Access to fans shall be via an insulated bottom panel with keyhole slots. Insulation 100Kg/m3 density, class ‘O’ CFC and HFC free open cell foam shall be utilised for both thermal acoustic insulation. Fans/Motors Fan/motor shall be permanent split capacitor external rotor ,forward curved centrifugal type, with high efficiency, low noise multiblade galvanised sheet steel impellers. Electrical supply shall be 230V 1ph 50Hz. Speed Control Speed control shall be by means of a multi-tapped transformer giving eleven settings. A panel mounted three speed switch with additional Fine adjustment. On/off control to fans shall be by means of a panel mounted illuminated two position switch. Coils Coil matrix blocks shall be copper with aluminium fins. Fitted with vents and drains as standard Condensate Tray Condensate trays shall be synthetically treated, galvanised sheet steel, foam insulated. A positive fall to drain shall be provided with 3/4&quot; B.S.P. female bottom connection. Filters Filters shall be washable EU3, continuous filament media. Acoustic Flex 1 metre of 200mm diameter Sonodec25 acoustic flexible ducting is supplied for each outlet spigot. Sonodec25 is insulated both acoustically and thermally with 25mm fibreglass. Two 'Zip tie' clips are supplied for each discharge duct. Diffusers Linear Slot Diffusers (LS) The 3 slot linear diffuser are fully adjustable giving both horizontal and vertical projection. Manufactured from extruded aluminium and come with RAL9010 eggshell White powder coat frames Each diffuser is 1195mm x 179mm. Louvred-Faced (LF) Diffusers The louvred-faced diffusers are manufactured from extruded aluminium profiles with a 4 way removable core. All diffusers are finished in RAL9010 Eggshell White power coat. The square diffuser is 373mm x 373mm overall or an optional 595mm x 595mm overall diffuser can be ordered Plenum Box Each diffuser is supplied with a galvanised sheet steel plenum box, complete with 198mm diameter side entry spigot and cord operated damper. . Please click here to copy the specification to your clipboard ready to paste into your project specification. Click to see Actionair Fancoil i-drop library and drop drawings into your Autodesk application with &#8220;Download idrop indicator&#8221; To learn more about i-drop technology click here.   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l ALL");sQ1[43]=new Array("http://www.actionair.co.uk/pdf/Actionpacem.pdf","2726 Actionpac_EM_June 2003","","August 2003 Actionpac EM Actionair Actionpac EM Electro ­ Mechanical Control and Monitoring System Range and Features Actionpac Electro Mechanical Smoke and Fire Damper Control System. Automatic damper operation utilising Relay Logic and LED indication of damper status. Damper Panels: Customised Central Control Panel. Remote Repeater Panel. Fire Damper Monitor Panel. Specialist Panels available: q Fan Control Panel. q Fireman's Control Panel. q Mimic Panel. Example Actionpac EM Panel shown Dampers Designed and Built in Britain. Patent Nos. Pending Actionpac EM Smoke... the silent killer Electro-Mechanical Control and Monitoring System Introduction The Actionpac Electro-Mechanical Control System, consists of a number of smoke/fire dampers hard wired individually or in groups to a central control panel. The dampers may be individually or collectively controlled and continuously monitored. Dampers and control modes may have differing control and monitoring requirements and therefore will be connected to the site wiring, which when installed by the contractor, shall provide the relevant specified functions. Specification The Control Panel typically consists of the appropriate number of switches to provide individual or group control, LED indication for status monitoring and all necessary relays and timers to comply with the customer needs for fully or semi- automatic damper operation. Interface with the Fire Alarm panel is via volt-free contacts which are normally closed and open upon alarm, the damper control panel will then activate relevant dampers to their alarm status. Damper Control Panels are purposely manufactured for any particular project to suit as specific customer requirements. Features Damper control panels are purposely manufactured for any particular project to suit specific customer requirements. Dampers can be individually or collectively controlled and continually monitored. Wall mounted enclosures to IP55. Custom engraved traffolyte fascia. LED indication of damper status. Zonal inputs. Door interlocking isolator. Miniature circuit breaker protection. Options Lockable glazed door. Special paint finish to British Standard Reference Number. Flush mounting flanges. Latching push buttons. Fireman's override key switches. Test switch. Audible alarm with mute facility. B.M.S common fault relay interface. B.M.S output. Delay timers. Battery backup. Specialist panels available q Repeater Monitor Panel q Fan Control Panel q Fireman's Control Panel q Mimic Control Panel. Example Actionpac EM Panel shown 2 Actionpac EM Typical Actionpac Electro-Mechanical System Schematic Incorporating Smoke/Shield PTCTM (Control Mode 5 illustrated) SUPPLY 240V 1ph EITHER 1 No. 24V AC OUTPUT PER ZONE TO ALL MODE 5 DAMPER ACTUATORS IN THAT ZONE (SUBJECT TO LOADING) FOR INDIVIDUAL CONTROL 1 No. 24V AC OUTPUT PER MODE 5 DAMPER ACTUATOR 1 2 S5 OR FIRE ALARM PANEL ACTIONPAC ELECTRO-MECHANICAL CONTROL PANEL S6 S4 SMOKE/SHIELD PTC CONTROL MODE 5 S1 S2 FIREMANS OVERRIDE PANEL 3 CORE INDICATION BACK FROM EACH INDIVIDUAL MODE 5 S3 INTERFACE : 1 No. VOLT FREE CONTACT PER ZONE 1 X 2 CORE CABLE PER INTERFACE 1 x 2 CORE BMS DAMPER COMMON FAULT INTERFACE MODE 5 LOCAL CONNECTION BOX (OPTIONAL) For wiring and application details on the various Actionair damper and control options, please refer to relevant product brochure and Customer Service Office. Commissioning Actionair offers a comprehensive after sales service to include for precommissioning checks, complete commissioning service of all our products in line with and to encompass CIBSE guidelines and planned preventive maintenance visits. Panel Enclosure sizes No. of Dampers 1-4 5-8 9 - 12 13 - 16 17 - 20 21 - 30 31 - 40 41 - 50 Estimated enclosure size (mm) 400 x 400 x 200 400 x 400 x 200 500 x 500 x 200 500 x 500 x 200 600 x 600 x 200 600 x 600 x 200 800 x 600 x 250 800 x 800 x 250 For greater number of Dampers contact Technical Sales Office. Accessories CB Connection Box For Control Modes. (Can be factory prewired to Control Mode.) Size: 100 x 100 x 50mm. PBOB Push Button Operator Box For Control Modes. (Illuminated switch to reset and release damper.) Size: 100 x 100 x 50mm. DTU Damper Test Unit For Control Modes. Spring bias test switch providing illuminated reset and release status.) Size: 88 x 88 x 55mm. 3 Other Products w w w . a c t i o n a i r. c o . u k Actionpac LNS Addressable Smoke and Fire Damper Control System Actionair Smoke/Shield PTC Automatic Smoke and Fire Dampers Panel PC driven system For control of a greater number of Dampers, offering a more flexible approach through software configuration. For more details please contact our Technical Sales Office. q Fully compliant to the new International (ISO 10294-1), European (EN 1366-2) and British (BS ISO 10294-1 and BS 476 Part 20), Fire Damper test standards. q Unique SnaplockTM drive interface ensures user friendly connection of control mode to damper. q New proportional torque control for optimised torque performance q Unique and patented electrical thermal release for ultimate safety. q Easy connection to square, rectangular, circular and flat oval ductwork. The information contained herein is subject to change without notice due to continuing research and development. Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. NO COMPROMISE. Quality System Certificate No 017 Assessed to ISO 9001:2000 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited PRODUCED BY GRAPHIC PARTNERSHIP 01227 280877");sQ1[44]=new Array("http://www.actionair.co.uk/pdf/ActionpacLNS.pdf","Actionpac LNS 3.qxd","","November 2005 Actionpac LNS 3 Actionpac LNS3 Intelligent Damper Control and Monitoring System Range and Features Panel PC Driven system. User friendly, no need for operating and maintenance manual. Full diagnostic for system and device integration from Panel PC. Flexible system architecture, enables sophisticated as well as simple fire engineering configurations. Network ­ unidirectional 2 core cable, utilising daisy chain method of wiring to all devices ­ reducing wiring costs. Centralised or localised wiring to input and output devices, reducing wiring costs. Graphic User Interface operates on a windows platform making it universally accepted. Localised supplies to all devices. Will control and monitor many variants of Actionair motorised Dampers. www.actionair.co.uk N EW ED C AN H EN D AN Actionpac LNS3 Smoke... the silent killer Control and Monitoring System Introduction Consultants in the field of fire engineering have long recognised the damage and danger to human life that can be caused by smoke spreading through buildings, even when the fire is confined to a small area. Smoke/fire protection can save human lives as well as keeping damage to property and contents to an absolute minimum. C o n t ro l measures for smoke/fire protection in old and new buildings comprise a wide variety of systems and items of equipment, that must be carefully integrated in order to ensure maximum safety. One of the most important tasks is performed by the automatic smoke and fire dampers that are incorporated into HVAC systems. In an emergency they must close immediately to contain the smoke and fire and prevent their spread through the ducting, or open immediately to allow smoke extraction to take place. The Actionpac LNS3 system represents a new generation of smoke/fire damper control. The system has been designed with the user in mind, providing an advanced tool that simplifies installation and commissioning of smoke/fire dampers and peripheral devices. The Panel PC operates on a WindowsTM platform making it universally accepted and utilises solid state technology for optimum reliability. It's server architecture delivers new benefits such as reduced commissioning time, simplified operation and scope for future growth. The Actionpac LNS3 Intelligent Smoke and Fire Damper typical Control System application. The Actionpac LNS3 system is designed to protect life and property from damage caused by smoke and fire, by providing the means to:­ · · Compartmentalise fire zones. Reduce the spread of smoke and fire. · · Keep escape routes and fire-fighting access open. Allow pressurisation and smoke extract by combined operation of dampers and fans. Denotes Automatic Smoke and Fire Damper in smoke containing Mode on the first floor whilst offering pressurisation to immediate floors (above and below) and stairwell. S + + + + Actionpac Ground Level Entrance + + + 2 www.actionair.co.uk Control and Monitoring System Actionpac LNS3 Specification Control Panel The Actionpac LNS3 System consists of a Panel PC,UPS and preloaded software. The system communicates with the damper interfaces to provide intelligent control and monitoring of motorised dampers. The data network cabling enables substantial reduction in costs when compared with conventional systems. Digital inputs and outputs (DX-8) can be accommodated on the network cable or located within the panel enclosure. The Panel PC is supplied with Actionpac LNS3 software and operates on a WindowsTM platform, making it extremely user friendly. The server architecture delivers new benefits, such as reduced commissioning time, ease of configuration, simplified operation and system growth. Full diagnostics for system and device integration from the Panel PC, along with automatic scheduled damper testing facility to meet new European damper test standards. Digital Input / Output Device DX-8 This device accepts eight volt free contact inputs into the Actionpac LNS3 system. Typical inputs would be from fire alarm panels, fireman 's override switches,manual call points and smoke detectors. This device also provides eight relay outputs to be driven from the Actionpac LNS3 system. Typical outputs would be to fans and BMS systems. Large strategy (cause and effect) lists can be driven from these input / output devices and they can be placed anywhere on the network to reduce cabling costs, or located within the Panel PC enclosure. Mimic Panels Bespoke LED mimic panels are available to clients' specification. Firefighter's Override Panels (FOP) Bespoke key switch or push button firefighter's override panels are available to clients' specification. Damper Interfaces All the damper interfaces accept local auxiliary inputs (normally smoke detectors) which can drive cause and effect schedules. Smoke Fire Damper Interface (SFDI) This device,which is a registered LonMark ® FSDAC product, can be used with the Actionpac LNS3 system or in smaller distributed systems as it is supplied complete with software. The SFDI controls and monitors motorised smoke/fire dampers. The device ensures correct operation and status of the damper and provides an alarm at the PC Panel in the event of local power supply failure. Smoke Damper Interface (SDI) This device controls and monitors motorised smoke dampers. Fire Damper Interface (FDI) Monitors damper position and provides facility for energising an electromagnet. Damper failsafes closed via spring mechanism and must be manually reset. www.actionair.co.uk 3 Actionpac LNS3 Control and Monitoring System Wiring Detail Control Mode Smoke Fire Damper interface CONTROL MODE DRIVE L N 90° 0° 1 2 S1 S2 S3 S4 S5 S6 L N ISOLATE ISOLATE IN OUT TF 72 °C POWER IN NETWORK ELECTRICAL THERMAL RELEASE SMOKE FIRE DAMPER INTERFACE (SHOULD BE POSITIONED &lt; 1 METRE FROM THE DAMPER CONTROL MODE TO ALLOW FOR DIRECT CONNECTION OF THE FLYING LEADS, 3 + 5 METERS FLYING LEADS AVAILABLE ON REQUEST Control Options System will control and monitor any motorised damper and offer monitoring of any manual reset. Typical operation Power On ­ Damper resets Power Off ­ Spring release External mechanical position indicator with pointer. Release Time 20 secs. Reset Time 60 secs. 24V A.C.or D.C. Connect 24V via a safety isolating transformer. 220 ­ 240V A.C.50 / 60Hz To isolate from main power supply, the system must incorporate a device which disconnects the phase at least 3mm contact gap. Power Consumption 24V A.C. or D.C. 220V - 240V A.C. M a x i m u m power consumption for c o m b i n e d SFDI plus 24V or 230V actuator is &lt;13W. Cable Specifications Cable Type Belden 8471NH Pirelli FP200 Gold Pirelli FP PLUS Firetuf Firetuf Plus Max device to device 400m 400m 400m 400m 400m Max total cable 500m 500m 500m 500m 500m Conductor size 1.3mm2 1.5mm2 1.5mm2 1.5mm 2 1. Maximum number of devices per cable segment is 64. If &gt;64 and / or &gt;500m cable segment, use a network extender kit. 2. If wired as a loop,the network is polarity sensitive. In all other instances, the network is polarity insensitive. 3. Each cable segment must be wired in a `daisy chain' i.e. in and out and no stubs will be allowed. 4. Belden 8471NH is not fire rated. 1.5mm2 These cable specifications are fundamental to the stable and reliable operation of your smoke/fire control and monitoring system. Failure to adhere to these specifications will result in unstable and unreliable network communications and will void all warranties. 4 www.actionair.co.uk Control and Monitoring System Actionpac LNS3 Typical Network Schematic General Schematic of Actionpac LNS Damper Control System Panel PC Data Network B.M.S. Vent Panel SFDI SFDI SFDI OUTPUTS SFDI Smoke Fire Damper Interface One per Control Mode Damper Control Mode* DX - 8 INPUTS Device located in Panel on Network SFDI DX - 8 Digital Input / Output Device Interface to Fire System BMS Inputs Fire Alarm Inputs Fireman's Switch Inputs To additional devices as required *If more than one Damper to be controlled by an SFDI, SDI or FDI please refer to Actionair Sales Office. Supply to each Damper Interface from nearest local distribution board. Benefits · Completely flexible to meet practically any building's damper requirements · Allows for exact location of devices in text · Multiple wiring configurations to include Radial or Loop Topology · 3 levels of alarm priority Panel PC driven system with real-time graphic displays · Panel PC utilises solid state technology for optimum reliability · Damper operational count provided · Flexibility to accommodate any last minute changes to strateg, zones, damper additions, damper locations etc. · Operates on windowsTM platform ­ user friendly · Full configuration and diagnostics from Panel PC · Guaranteed input response times of &lt;10 seconds on a 512 damper system to meet the new draft BS EN 12101-9. · Automatic scheduled Damper testing www.actionair.co.uk 5 Actionpac LNS3 Control and Monitoring System Panel Specification Enclosure Specifications Standard enclosure sizes and weights are dependent on number of panel routers and DX8's required. Max load (Watts) 500 500 500 500 Enclosure Size (mm) 600 x 600 x 300 800 x 800 x 300 1000 x 800 x 300 1200 x 800 x 300 Colour Hinged Power cables Network cables I/O cables Protection Max ambient temperature RAL 7032 Left Bottom entry right hand side Top entry Top entry IP 20 (230 Volt terminals shrouded) 30 °C (Panel must be in a ventilated environment) 150mm Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. System Commissioning Actionair offers a comprehensive after sales service to include precommissioning checks and a complete commissioning service for all our products. Minimum clearance for vents 6 www.actionair.co.uk Control and Monitoring System Actionpac LNS3 Control Mode 5 PTC and Control Mode 6 PTC Control Mode 5 PTC and Control Mode 6 PTC 60 seconds MAX Reset/ 20 seconds Release operation. These new series of control modes achieve 60 seconds to drive to the end position, with a 20 second spring return time. This brings Actionair dampers in line with imminent European standardisation for fire and smoke control. As with all PTC modes, this series uses the snaplockTM interface. Fire rated dampers are primarily designed to be fitted into a wall or floor, and the interface displaces the mode from the line of the wall. Dampers may be installed and finally the mode removed from storage for easy fitting, thus preventing damage to the mode before it is required. End switches and LSF cable are provided as standard on all modes. Versions are available to allow fail-safe close for fire safety (Smoke/Shield) or fail-safe open for smoke extract (Vent/Shield) and may be combined with protective enclosures (Hot/Shield) to provide enhanced operation for 1 hour at 300 °C or 2 hours at 300 °C. The Electro Thermal Release (ETR) supplied for fire damper use has integral fail-safe devices to ensure that it is installed into the ductwork correctly. ETR units are not supplied with Hot/Shield, because these are designed to operate at temperatures in excess of 72 °C, should a fire cause any temperature rise. End switches are provided with each mode, so that damper Reset and Release positions may be monitored. The mode is permanently attached to the mechanism driving the damper blades. Smoke/Shield and Vent/Shield M5 PTC M6 PTC M5 PTC Vent M6 PTC Vent M5 PTC NON ETR M6 PTC NON ETR 24V 7W (10VA), 24V 7W (10VA), 24V 7W (10VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A XNNN00015 XNNN00016 XNNN00019 XNNN00020 XNNN00017 XNNN00018 XNNN00021 XNNN00022 Smoke/Shield Thermal Release / Power Off ­ Fail-safe Close* Smoke/Shield Thermal Release / Power Off ­ Fail-safe Close* Vent/Shield Vent/Shield Thermal Release / Power Off ­ Fail-safe Open* Thermal Release / Power Off ­ Fail-safe Open* 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A ETR Indication light As standard, a green LED lamp is built into the ETR housing. This gives the user a simple and clear visual check that the Actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. Smoke/Shield Power Off ­ Fail-safe Close Smoke/Shield Power Off ­ Fail-safe Close Vent/Shield Vent/Shield Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open M5 PTC Vent NON ETR 24V 7W (10VA), M6 PTC Vent NON ETR 230V 8W (12.5VA), end switches SPDT 250V 6(3)A *Smoke/Shield and Vent/Shield Control Modes M5 PTC and M6 PTC are supplied as standard with the Electrical Thermal Release (ETR). The units Fail-safe by means of the unique and patented ETR device which operates at 72 °C, or if the power supply is off/interrupted. Complying with BS 5588 Part 9 1999. Non ETR versions Fail-safe when the power is off/interrupted. Hot/Shield and Hot/Vent/Shield HM5 PTC HM6 PTC HM5 PTC Vent HM6 PTC Vent HM5-2H PTC HM6-2H PTC HM5-2H PTC Vent HM6-2H PTC Vent 24V 7W (10VA), 24V 7W (10VA), 24V 7W (10VA), 24V 7W (10VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A XNNN00281 XNNN00282 XNNN00283 XNNN00284 XNNN00285 XNNN00286 XNNN00287 XNNN00288 Hot/Shield Hot/Shield Hot/Vent/Shield Hot/Vent/Shield Hot/Shield Hot/Shield Hot/Vent/Shield Hot/Vent/Shield Power Off ­ Fail-safe Close Power Off ­ Fail-safe Close Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open Power Off ­ Fail-safe Close Power Off ­ Fail-safe Close Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A Hot/Shield and Hot/Vent/Shield Control Modes HM5 PTC and HM6 PTC (operational for 1 hour @ 300 °C) and HM5 ­ 2H PTC and HM6 ­ 2H PTC (operational for 2 hours @ 300 °C) are not supplied with the Electrical Thermal Release (ETR). They Fail-safe when the power is off/interrupted). www.acwiww.aatiir.naoc.o.uk t on c o cir. u k 7 Actionpac LNS3 w w w . a c t i o n a i r. c o . u k Actionpac Electro Mechanical Smoke and Fire Damper Hard Wired Control Panels EMS ­ Standard EMB ­ Bespoke Control and Monitoring System Actionpac Electro Mechanical Smoke and Fire Damper Control System. Automatic damper operation utilising Relay Logic and LED indication of damper status. Damper Panels: Customised Central Control Panel. Remote Repeater Panel. Fire Damper Monitor Panel. Specialist Panels available: G Fan Control Panel. G Fireman's Control Panel. G Mimic Panel. Example Actionpac EMB Panel Please Note: Actionpac LNS3 is recommended when greater numbers of Smoke/Shield Dampers are to be controlled / monitored. Sometimes, depending on project requirements, it may also be advantageous to utilise Actionpac LNS3 on smaller numbers of Smoke / Fire Dampers. Please refer to Actionair Sales Office. Example Actionpac EMS Panel no compromise... Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited Quality System Certificate No 017 Assessed to ISO 9001:2000 PRODUCED BY: www.graphicpartnership.com");sQ1[45]=new Array("http://www.actionair.co.uk/pdf/fire.pdf","2966 Fire/Shield May 2004.qxd","","May 2004 Fire/Shield Innovative cassette, new design with even easier singlehanded reset. Actionair Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Features and Design Guide Damper tested by LPC/BRE up to 4 hour applications, Product Certification Awarded by the Loss Prevention Certification Board Limited. (LPCB). Tested to BS ISO 10294-1: 1996, BS EN 1366-2: 1999 and BS 476 Part 20: 1987 Fire Test Standards. Corrosion tested. New Self-Latching Removable Cassette, with even easier Single Handed Reset. Stainless Steel folding curtain. Choice of 230 Volt A.C. or 24 Volt A.C. and D.C. remote electro magnet fail-safe releases on cassette type options only. Fire/Shield Innovative cassette, The Range The Fire/Shield range of quality engineered dampers are suitable for air conditioning and ventilation systems requiring up to 4 hour fire protection. These stainless steel bladed Actionair Fire/Shield Dampers fail-safe closed and are supplied with the new innovative, even easier Single-Handed Reset Self Latching Removable Release Mechanism Cassette, which permits single handed reset. Application Parameters Fire/Shield Dampers are designed for application in normal dry filtered air systems. If exposed to fresh air intakes and/or inclement conditions the damper should be subject to a planned inspection programme. Any specialists and/or aggressive applications (e.g. swimming pools) may invalidate our warranty, please refer to Actionair Sales Office. Cassette Ordinary steel curtain fire dampers involve a complex pull and lift curtain opening operation, further complicated by having to hold the curtain in the fully open position against the constant tension of closure springs whilst attempting to reset or replace the fusible link unsighted. Cassette Details q Patented design. q Made of Polyphenylenesulphide (PPS) resin reinforced with 40% glass (GF-PPS). q Technically advanced engineering polymer. Blade Features The Type 1.4016 (430) Ferritic Stainless Steel folding blade curtain, providing maximum strength, form a fire shield. The wide profile blades maximise the damper free area and ensure compact grouping to minimise blade stacking height. Optional blade construction Type 1.4401 (316) Austenitic Stainless Steel. Side Seal Gasketing Stainless Steel side seal gasketing provides constant pressure on blade edges, minimising the spread of smoke and other products of combustion. Ordinary steel curtain fire dampers may not have side seal gasketing. q PPS is stable at temperatures up to 200 °C. makes these dampers suitable for inclusion into air distribution systems to the test methods of Eurovent Class A, B & C and HVCA Ductwork specification DW144. These galvanised casings are manufactured with either Square, Rectangular, Circular or Flat Oval duct connections. As an option, casings can be manufactured in Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic Stainless Steel. q Cassette construction is of very high strength and has excellent creep and fatigue resistance. q Low smoke and toxic emissions in fire conditions. q Halogen free q PPS has a very low moisture absorption. q PPS is corrosion resistant. q The Cassette construction is environmentally friendly (recyclable material). q The new Cassette is retrofittable to existing Fire/Shield Dampers (by use of a simple optional adaption bracket). q One Cassette to suit all damper material options. Ordinar y steel curtain fire dampers for low or medium velocity operation and having the blades and/or part of the casing frame in the airstream may not have casings of continuous welded airtight construction. Stainless Steel Closure Springs Stainless Steel constant tension springs are fitted and positioned out of the airstream to close and latch the damper, regardless of vertical or horizontal operation. Spigotted Casing Features The spigotted casing with continuously welded corners and spigot connections, 2 Fire/Shield ... new design with even easier single-handed reset Self Latching Removable Release Mechanism Cassette The cassette mechanism is completely removable from the Fire/Shield Damper by manually releasing the retaining clip. This allows replacement of the cassette without the use of tools. Simple hand operation enables the damper curtain to be reset and latched in the fully Open Position. This increases the ease and speed with which the Fire/Shield Damper can be reset following periodic functional testing in accordance with British Standard BS 5588: Part 9 Code of Practice for Ventilation and Air Conditioning Ductwork. The thermal actuator in the form of a helical memory metal compression spring is produced from a special Cu-Zn-AI brass alloy. On temperature rise this expands and at 72 °C, causes the Fire/Shield damper blades to release. On cooling, the spring reverts to the close-coiled state offering the significant advantage of repeated operation, unless it has reached temperatures in excess of 170 °C, where it will remain extended, preventing reset. Cassettes are only available for 72 °C. For Dampers where alternative thermal link temperatures are required a chain-link can be offered in place of a cassette. Electrical release is only available with a cassette i.e. 72 °C. Please refer to Actionair Sales Office. Please note: For dampers with dimensions of 150mm and below ensure that there is adequate access to enable re-setting. Release Mechanism Support Bracket Retaining clip Cassette Set Position Manual Operation Manual Operation for periodic functional testing in accordance with British Standard BS 5588: Part 9 Code of Practice for Ventilation and Air Conditioning Ductwork. Thermal Actuator Operation Memory metal coil springs, specially designed to fully expand at 72 °C and actuate damper closure. Remote Release Operation Remote release operation to close the Fire/Shield Damper is by Bowden cable with Manual action or Electrical 230V A.C. or 24V A.C. and D.C. Electro Magnet fail-safe action and independent of the thermal actuators. Reset Operation Single hand operation. Each blade pushes the latch back under spring tension. On full blade reset the latch springs out to secure. 3 Fire/Shield External Visual Blade Position Indication An external indicator is factory fitted to the access (cassette) side of the damper casing giving visual indication of damper blade position. A spring steel actuator ensures automatic resetting of the external indicator in either horizontal or vertical applications. The external indicator is especially beneficial at the system balancing and commissioning stage eliminating the necessity of internal duct inspection to determine the fire damper open or closed position. Accessories Galvanised Steel Installation Frames (as required by HVC 6/5/83 Rev.1 July 1999.) Installation frames are delivered to site as a complete assembly with the appropriate Fire/Shield Damper fitted therein. The frame shall be installed centrally in the thickness of a brick, blockwork or concrete surrounding wall or floor, or in the case of thick walls or floors, so that the centre line of the frame is at least 50mm away from the nearest face of the wall or floor in which the assembly is mounted. The four tabs (building tie) forming each fixing point shall provide a positive fixing into the structure. Multiple assembly dampers up to 1500 x 1500 or 2000 x 1000 can be fitted into fully assembled installation frames and delivered as one piece. Dampers in excess of this size will be supplied in sections with the installation frame supplied in kit form. A drawing and method statement will be supplied for the assembly to be fitted on site. The maximum size of kit form installation frames will be to accommodate a four section assembly. a. In brick or blockwork walls the tabs shall be bent out and solidly built into the mortar joints between the brick or blockwork. b. In the case of reinforced concrete walls and floors, the tabs shall be bent out and tied with wire to the reinforcing bars which will be deliberately left protruding into the opening. The gap between the installation frame and builders work shall be backfilled with mortar or concrete on both sides of the flange. Adjacent frame assemblies must be separated by builders work of a minimum thickness of 225mm (between installation frame upstand flanges) unless approval has been previously obtained from the appropriate Authority. For solutions below this dimension please refer to Actionair Sales office. In no case shall the HEVAC/HVCA frame and damper assembly be held in position merely by the adjacent ductwork, and it should be noted that in reinforced concrete structures (especially floors), it will not be sufficient to only backfill between the damper installation frame and the surrounding opening with mortar or fine aggregate concrete mix without provision for tying in the frame to the surrounding reinforced concrete structure. Galvanised steel frame, the corners left open with predetermined clearance space to permit the expansion of the complete assembly in a fire condition. Pressed steel corner brackets retain frame open corners in such a manner that all corners maintain their integrity against the passage of smoke or flame between the frame and the damper casing. Aluminium rivets fix the pressed steel corner brackets to the frame and collapse in a fire situation to allow internal expansion of the installation frame. A binder containing certain approved installation illustrations is available, please contact the Sales Office or visit our website, www. actionair.co.uk. Although the included methods have been tested and assessed, it is recommend, that these, as with all installation methods must be confirmed with Building Control / Local Authority prior to manufacture. Actionair can also provide applications of other proposed methods of installation, please contact our Sales Office to discuss your specific requirements. These again are the responsibility of the client to ensure that these are acceptable to Building Control / Local Authority before construction commences. Fluorescent Red Display Indicating damper blades in closed position. Note: External visual blade position indication is not available with special finished casings, certain multiple assemblies, miscellaneous Damper configurations and due to physical size limitations is not available below 125mm dia. on Series 301 Dampers. Galvanised steel spacer sections located at each corner maintain clearance between frame and damper casing to permit the expansion of the latter in a fire condition. All Fire Damper installations require relevant Local Authority approval. 4 Fire/Shield Multiple Assemblies Square and rectangular casings are available in multiple module arrangements, supplied complete with connecting channels for site fixing by others. Multiple Vertical Arrangement (1) Series 201 or 101 as required mounted on Series 101 can also be arranged 3 off dampers high to give maximum duct height of 3100mm. Duct width as required. Bottom d a m p e r s only provided with external v i s u al indication of blade position. Note: Should more than 3 off dampers high be required, adequate damper supports are necessary and must be provided. Please refer to Actionair Sales Office. (2) Multiple Vertical Arrangement (2) Series 101 shown. Series 201 can be mounted similarly. Maximum duct height 1000mm. Maximum duct width as required. Horizontal arrangement similar. External visual indication of blade position provided with all dampers. (1) Weights Approximate Weights (Kg) SQUARE/CIRCULAR DUCT SIZE (MM) SERIES 101 +I/F SERIES 201 +I/F SERIES 301 +I/F 4.4 5.5 6.9 9.0 10.4 11.7 13.6 15.5 16.5 18.5 20.3 22.2 42.5 27.8 30.4 32.8 35.2 38.9 42.0 SERIES 101 SERIES 201 SERIES 301 2.3 3.0 4.0 4.1 4.6 5.4 6.0 7.1 8.0 9.3 10.5 12.1 12.7 14.4 16.0 17.5 19.0 20.5 22.0 7.4 8.5 9.6 10.4 12.6 13.8 15.3 16.8 18.0 20.3 21.7 23.6 25.5 27.6 29.8 32.0 5.4 6.5 7.6 8.8 10.2 11.7 13.2 14.9 16.9 18.7 20.5 22.4 24.5 26.7 28.8 31.0 ACCESS SIDE 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 1.6 2.1 2.8 3.5 4.2 5.0 5.7 6.9 7.5 8.6 9.5 10.9 12.0 13.1 13.8 15.2 16.7 18.1 19.0 3.8 4.6 5.7 6.8 8.0 9.2 10.7 11.8 12.9 14.1 15.8 17.9 19.1 20.2 21.3 23.3 25.2 27.4 29.2 Please use series 101 dampers for duct heights below 250mm Multiple Horizontal Arrangement (3) Series 201 shown. Series 101 can be mounted similarly, four or more sections. Maximum duct height 2050mm. External visual indication of damper blade position not relevant to this application. (3) 950 1000 For Series 401 and Series 401 +I/F please contact Actionair Sales Office. Note: For Series 201 Multiple Height Arrangement specify Vertical or Horizontal application. Remote Electrical Fail-Safe Releases 230 Volt A.C. and 24 Volt A.C. and D.C. Electro magnet releases are available, for use with cassette mechanisms only. 280 CORRUGATED CONTAINER SIZE 330 X 150 X 130mm Weight = 1.6 Kg APPROXIMATELY Micro Switches All Series Fire/Shield Dampers are available with factory fitted single or double pole micro switches as optional extras to provide remote electrical indication of damper status and/or controls interface. 105 75 230V A.C. BROWN BLUE GREEN/YELLOW L N SUPPLY 230V 1PH 50Hz 10mA CONTINUOUS LOADS PUSH FIT TO BRACKET E 24V A.C. and D.C. BROWN BLUE GREEN/YELLOW + E SUPPLY 24V 1PH 50Hz 120mA CONTINUOUS LOADS Note: For Dampers below 200 x 200mm or 200mm diameter micro switches will be factory fitted on the non access side. Terminal blocks supplied by others. 5 Fire/Shield Dimensional Data Basic Dampers Series 101 Fire/Shield Dampers with blades partly in airstream Dampers with Installation Frames OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 90 (Damper spigots 5mm under duct size) 25 DUCT HEIGHT DUCT HEIGHT 25 DUCT WIDTH 100-1250 25 100 - 1000 Series 201 Fire/Shield Dampers with blades effectively outside airstream (Damper spigots 5mm under duct size) 50 75 100 * USES SERIES 101 DAMPERS FOR DUCT HEIGHTS BELOW 250 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 90 57 DUCT HEIGHT 25 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 92 38 78 38 25 DUCT HEIGHT 25 * 250 - 624 625 - 850 851 - 1000 Series 301 Fire/Shield Dampers with blades effectively outside airstream (Damper spigots 3mm under duct size) 25 50 75 100 57 DUCT DIAMETER 25 57 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 114 92 38 78 38 25 DUCT WIDTH 100-1250 DUCT DIAMETER 100 - 249 250 - 624 625 - 850 851 - 1000 25 60 82 60 25 DUCT DIAMETER 100-1000 Series 401 Fire/Shield Dampers with blades effectively outside airstream (Damper spigots 3mm under duct size) 25 50 DUCT HEIGHT DUCT HEIGHT 25 57 DUCT WIDTH 300-1250 25 100 - 249 250 - 500 60 82 60 25 6 100 - 249 250 - 500 57 83 100 - 249 250 - 624 625 - 850 851 - 1000 57 83 108 133 * 250 - 624 625 - 850 851 - 1000 83 108 133 100 - 1000 57 Fire/Shield Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of Fire/Shield Stainless Steel Curtain Fire Dampers. A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound Research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos., 4196, 4773, 4856, 4857 and 4954. This independent test facility is approved under the NAMAS Scheme. For a selection of duct velocity within the operational parameters of the dampers a resultant pressure drop can be determined and the sum of these two components applied to the Velocity X Pressure Drop Vs Sound Power Level Graph. The Sound Power Level Graphs are a result of a full range of acoustic tests on Fire/Shield Series 101, 201 and 301 dampers. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Breakout (casing radiated) and Outlet (in duct) is obtained. Specification Pressure Drop Vs Velocity 100 90 80 70 60 50 40 Fire/Shield Curtain fire dampers comprising of a stainless steel folding curtain having unbroken movable joints, stainless steel constant tension closure springs for positive closure and stainless steel peripheral gasketing. The Self Resettable, Latching Removable Release Mechanism Cassette, shall ensure the closure of the stainless steel curtain under full fire conditions. All housed in a galvanised steel fully welded spigotted type casing suitable for square, rectangular, circular or flat oval connections. Fire/Shield as supplied by Actionair. (Alternative rated release temperatures to 72 °C are catered for by a chain type link, please refer to Actionair Sales Office for details.) 301 30 20 PRESSURE DROP (Pa) 10 9 8 7 6 5 4 3 01 S1 S2 01 SE R IES RIE SE 1 1 2 3 4 5 6 7 8 910 20 VELOCITY m/s Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) 90 1 20 ut (O let ) SE RIE 2 A Fire Rated Damper in accordance with British Standard 5588: Part 9: 1999 should be held in the Open Position by means of a Thermally Actuated Device set to operate at approximately 74 °C. All Fire/Shield Stainless Steel Curtain Fire Dampers are Fire Rated Dampers as they are held in the Open Position by a Thermally Actuated l i n k operating at a temperature of approximately 72 °C ± 4 °C. The fitting of a Thermally Actuated Link operating at a higher temperature requires approval by the local relevant Local Authority. 80 E RI SE S SOUND POWER LEVEL (dBW) 70 1 30 t) le ut (O 60 let ) ES RI SE 50 S I ER ES 10 1 (O ut 40 1& 10 IES ER S 1 20 ut) kO rea (B SE 40 RI ES 30 1 (B a re k Ou t) Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. Testing and Maintenance Fire/Shield Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication in accordance with good industry practice. All Fire/Shield Dampers should be tested by competent persons on completion of the installation and at regular intervals not exceeding two years. Spring operated fire dampers should be tested annually and fire dampers situated in dust laden and similar atmospheres should be tested much more frequently, at intervals suited to the degree of pollution. (All in accordance with BS5588-9 1999 Test Frequency). 30 6000 7000 8000 9000 10000 500 600 700 800 900 1000 50 60 70 80 90 100 2000 3000 4000 5000 200 300 400 10 20 30 VELOCITY X PRESSURE DROP (m/s Pa) Fire/Shield Breakout Spectrum Correction Octave band 63 125 250 500 SERIES 101 ­10 ­7 ­3 ­9 SERIES 201 ­10 ­7 ­3 ­9 SERIES 301 ­13 ­10 ­3 ­7 Fire/Shield Outlet (Induct) Spectrum Octave band 63 125 250 SERIES 101 ­4 ­12 ­16 SERIES 201 ­4 ­11 ­17 SERIES 301 ­4 ­10 ­16 1K ­13 ­13 ­11 2K ­20 ­20 ­12 2K ­29 ­30 ­24 4K ­30 ­30 ­26 4K ­32 ­33 ­30 8K ­33 ­33 ­42 8K ­38 ­40 ­38 Hz dB -dB -dB Hz dB dB dB Correction 500 1K ­18 ­22 ­19 ­22 ­18 ­21 7 Fire/ Shield w w w . a c t i o n a i r. c o . u k Standard Ordering Procedure Please Specify Quantity Series Number Required. FS101 Square/Rectangular (blades partly in airstream). FS201 Square/Rectangular (blades outside airstream). FS301 Circular (blades outside airstream). FS401 Flat Oval (blades outside airstream). Accessories IF Installation Frame. Product Range Smoke/Shield PTCTM Automatic Smoke and Fire Dampers Vent/Shield PTCTM Automatic Smoke Release Dampers Hot/Shield PTCTM High Operating Temperature Automatic Smoke and Fire Dampers Hot/Shield Vent PTCTM High Operating Temperature Automatic Smoke Release Dampers Actionpac LNS Addressable Smoke and Fire Damper Control Systems Actionpac EM Electro Mechanical Smoke and Fire Damper Control Systems Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Trans/Shield Air Transfer Smoke and Fire Dampers EM240 240V A.C. Electromagnet release. EM24 24V A.C. and D.C. Electromagnet release. MSSP Single pole microswitch. MSDP Double pole microswitch. Duct Size Nominal Damper Spigot Size. Example 2 / FS201 / IF / 1000(W) x 600(H) Air/Shield System Air Balancing and Shut-off Dampers Energy/Shield Heavy Duty Air Control and Shut-off Dampers Flame/Shield Adjustable Coated Baffle Grease Filters Access/Shield Series Circle / Oval / Tab Type Removable Access Doors PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.com Quantity Series Accessories Duct Size For further application, technical and pricing information, please refer to Actionair Sales Office. Hydropac PHW 230 Horizontal Waterside Control Fan Coil Units Aeropac PHA 230 Horizontal Airside Control Fan Coil Units Hydropac PHW 170 Horizontal Slimline Waterside Control Fan Coil Units Hydropac PVW 230 Vertical Waterside Control Fan Coil Units A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects Systempac Fan Coil Unit / Acoustic Flex / Diffuser System Package no compromise... Quality System Certificate No 017 Assessed to ISO 9002 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited");sQ1[46]=new Array("http://www.actionair.co.uk/newredcatalogues/HotShield.pdf","2871 Hot/Shield Nov 05.qxd","","March 2004 NOV 2005 PAGES 1 , 2 , 3 , 4 , 5 , 7 , an d 8 Hot/Shield PTCTM BROCHURE UPDATED * Actionair TM Hot /Shield PTC High Operating Temperature Smoke Management and Fire Dampers Features and Design Guide Smoke Management and Fire Dampers operational up to 300 °C for a period of 1 or 2 hours (two versions available). Thermally insulated electric Control Modes. Pneumatic option available 250 °C for one hour. Halogen free low smoke and fume cabling supplied as a standard feature. Low closed blade leakage. Dampers when closed are compliant to BS 476 Part 20 Fire Damper Test Standard. Actionpac Damper Control System compatibility. Hot/Shield Vent PTCTM reverse action dampers for High Operating Temperature Smoke Control and Extract applications. www.actionair.co.uk Dampers Designed and Built in Britain Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers Introduction Killers ­ have to be managed and controlled quickly and effectively to avoid confusion and panic from the threat posed to life safety and the extraction and control of these deadly gases is of paramount importance for the safe evacuation of the buildings occupants. The importance of the subsequent smoke damage that can occur to adjacent property and fittings is also recognised, as this can have disastrous effects on homes and businesses as recognised in the Loss Prevention Council Design Guide for Fire Protection in Buildings. Actionair have developed the Hot/Shield PTCTM High Temperature Smoke Management and Fire Dampers along with the Hot/Shield Vent PTCTM Smoke Control and Extract Dampers to enable the concepts of fire engineering to be employed in ducted smoke ventilation systems. These dampers designed, tested and approved to deliver high temperature operation at up to 300 °C for 1 and 2 hours, provide the designer with the capability of extracting hot smoke and combustion gases through a common smoke extraction duct linked to adjacent fire zones and floors. As smoke can spread rapidly and efficiently through a building ductwork system, damper operation needs to be initiated by a smoke detection system, as thermal sensing can often be too late. Hot/Shield PTCTM and Hot/Shield Vent PTCTM dampers are designed to be interfaced with a smoke detection/fire alarm system. Casings Features With double skin spigotted galvanised steel (to BS EN 10142) casing the Hot/Shield PTCTM dampers comply to Class A and B of Eurovent Document 2/2 and Test Procedures for Classes A, B and C of HVCA Ductwork Specification DW144. Damper casings are manufactured with fully welded spigotted connections suitable for Square, Rectangular, Circular and Flat Oval duct connections. As an extra cost option, casings can be manufactured in Type 1.4016 (430) Ferritic or Type 1.4401 (316) Austenitic Stainless Steel. Actionair have developed a new technically advanced thermal enclosure that actually has the ability to absorb heat energy when subjected to a high temperature environment. The performance criteria involves continuous operation of the complete damper and actuator assembly at elevated temperatures. This new enclosure is made from a phenolic composite resin with excellent endothermic properties. A chemical reaction occurs within the insulating material when it is heated. This reaction has the effect of lowering the temperature inside the enclosure, thus prolonging the duration of the actuator's operation at elevated temperatures. Smoke and other products of combustion kill at least 80% of recorded `fire victims', smoke is debilitating and can render people unconscious minimising their chances of survival. Many more die weeks or months later from the lingering effects and toxic effects of smoke inhalation. Smoke and toxic gases ­ the Silent Proportional Torque Control A new generation High Operating Temperature Smoke Management and Fire Damper, thermally Insulated Control Mode assembly, with a unique and dedicated Proportional Torque Control for optimised D a m p e r / C o n t ro l Mode torque performance. The unique snaplockTM drive interface ensures user friendly, easy and secure connection of the Control Mode to the Damper. The drive interface, which is totally independent of the ductwork, and provides ease of connection to square, rectangular, circular and flat oval ductwork, including Fire Rated Ductwork. Blade Features The Damper blades are aerodynamic,double skin (Type 1.4016 to BS EN 10088-2 Ferritic Stainless Steel) which are 75mm deep and interlock to form a positive smoke and fire resisting shield. Incorporated within the blade profile is a silicone seal to ensure low closed blade leakage at temperatures up to 300 °C for 1 or 2 hours. Stainless Steel blade end bearings and peripheral gasketting maintain the low closed blade leakage allowing for expansion under full fire conditions. Optional Blade construction Type 1.4401 (316) Austenitic Stainless Steel. Application Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers are designed for installation in high temperature ductwork systems with mechanical smoke extraction. As these ductwork systems regularly serve more than one fire zone or floor when smoke extraction is conducted from one area, it is essential to fully fire protect adjoining fire zones from ductwork penetrations that are connected to the smoke extract duct. For this purpose Hot/Shield PTCTM dampers, when closed are a fire rated damper to BS 476 part 20 for up to 2 hours, thus providing the fire isolation required. Closure of the Damper is achieved by removal/loss of the electrical supply.When used for smoke extraction, under authorised control, the Hot/Shield PTCTM damper will remain open under electrical power for a period of 1 or 2 hours at temperatures of up to 300 °C thus allowing the safe extraction of www.actionair.co.uk smoke and hot gases of combustion through the extended fire compartment created by the fire rated ductwork. Hot/Shield PTCTM Smoke Management Fire Dampers may also be used for controlled supply of make up air as a function of the fire engineering process. Hot/Shield Vent PTCTM High Operating Temperature Smoke Control and Extract Dampers provide flexible smoke management where other fire compartments are not interconnected to a common fire rated ductwork system. Designed to spring to the open position by stored energy and remain closed when powered. Hot/Shield Vent PTCTM dampers allow controlled smoke extraction to take place with a dedicated smoke control system if required, but retaining low leak closure of the smoke extract duct penetrations into the protected space during normal conditions. Parameters Hot/Shield PTCTM and Hot/Shield Vent PTCTM Dampers to maximum width and height dimensions (see page 6) can be used where the operating total system pressure is up to 1500 Pascals and duct velocities to 15m/second. As with any life safety damper product, a suitable planned inspection programme should be implemented. For specialist and /or aggressive applications, please refer to Actionair Sales Office. 2 High Operating Temperature Smoke Management and Fire Dampers Hot/Shield PTCTM Control Options A choice of a 24V or 230V Control Modes located outside the ductwork and (protected by its own thermally insulated e n c l o s u re ) and Halogen Free Low S m o k e and Fume cables, allows Hot/Shield PTCTM Damper control up to 3 0 0 °C for a period of 1 or 2 hours. The Control Mode upon receipt of the Hot/Shield and Hot/Vent/Shield HM5 PTC HM6 PTC HM5 PTC Vent HM6 PTC Vent HM5-2H PTC HM6-2H PTC HM5-2H PTC Vent HM6-2H PTC Vent 24V 7W (10VA), 24V 7W (10VA), 24V 7W (10VA), 24V 7W (10VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A XNNN00281 XNNN00282 XNNN00283 XNNN00284 XNNN00285 XNNN00286 XNNN00287 XNNN00288 Hot/Shield Hot/Shield Hot/Vent/Shield Hot/Vent/Shield Hot/Shield Hot/Shield Hot/Vent/Shield Hot/Vent/Shield Power Off ­ Fail-safe Close Power Off ­ Fail-safe Close Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open Power Off ­ Fail-safe Close Power Off ­ Fail-safe Close Power Off ­ Fail-safe Open Power Off ­ Fail-safe Open I I I I I I I I 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A 230V 8W (12.5VA), end switches SPDT 250V 6(3)A relevant supply voltage will motor the Damper to the open position. Closure of the Damper is achieved by removal/loss of the electrical supply. The Damper when closed will provide protection in accordance with BS 476 Part 20. Control Modes have two separate volt free contacts for the provision of external damper status indication. (No thermal links available). H o t / S h i e l d Vent PTCTM Dampers and associated Control Modes are reverse action with spring opening. I I See wiring detail below. Hot/Shield and Hot/Vent/Shield Control Modes HM5 PTC and HM6 PTC (operational for 1 hour @ 300 °C) and HM5 ­ 2H PTC and HM6 ­ 2H PTC (operational for 2 hours @ 300 °C) are NOT supplied with the Electrical Thermal Release (ETR). They Fail-safe when the power is off/interrupted). Hot/Shield and Hot/Vent/Shield HM5-3P PTC HM5-3P PTC Vent 24V 7W (10VA) end switches SPDT 250V 6(3)A XNNN00294 24V 7W (10VA) end switches SPDT 250V 6(3)A XNNN00295 Hot/Shield Power Off ­ Fail-safe Close 2-10V Set position 2-10V Set position Hot/Vent/Shield Power Off ­ Fail-safe Open Hot/Shield and Hot/Vent/Shield Control Modes HM5 ­ 3P PTC (operational for 1 hour @ 300 °C) are NOT supplied with Electrical Thermal Release (ETR) and Fail-safe when the power is off/interrupted. NOTE: 1 hour version only available. HM9 PTC Pneumatic Air Off ­ Fail-safe Close XNNN00301 XNNN00298 XNNN00299 HM9 PTC Vent Pneumatic Air Off ­ Fail-safe Open XNNN00304 Pneumatic version rated at 250 °C for 1 hour. Hot/ Shield and Hot/ Vent/ Shield 2 Position Drive Open / Drive Closed HM5-2P PTC HM6-2P PTC 24V 7W (10VA), 230V 8W (12.5VA), end switches SPDT 250V 6(3)A end switches SPDT 250V 6(3)A HM5-2P and HM6-2P are NOT supplied with ETR and remain in the desired emergency position when power is interrupted. Application and Wiring Mode HM5 (24V System) and HM5 2H Power On ­ Damper motors open. Power Off ­ Spring closure. Cable specification: Si HF Low Smoke and Fume, Halogen Free, to IEC 754-1. Conforming to 73/23/EEC directive. Release Time 22 secs. Reset Time 60 secs. (Connect 24V via a safety isolating transformer.) Mode HM6 (230V System) and HM6 2H Power On ­ Damper motors open. Power Off ­ Spring closure. Cable specification: Si HF Low Smoke and Fume, Halogen Free, to IEC 754-1. Conforming to 73/23/EEC directive. Release Time 22 secs. Reset Time 60 secs. (To isolate from main power supply, the system must incorporate a device which disconnects the phase conductors, with a least 3mm contact gap.) 1 A.C./D.C.24V 50 / 60 Hz ­ + SUPPLY 24V A.C. or D.C. M 2 1 10 V A 7/2 W A.C. 250V 6(3)A 2 3 4 VOLT FREE CONTACT CLOSED WHEN DAMPER RELEASED ­ 30...+50 °C CONTINUOUS VOLT FREE CONTACT CLOSED WHEN DAMPER RESET BLUE N L1 SUPPLY 230V A.C 50/60 Hz A.C. 230V 50 / 60 Hz M BROWN 1 12.5 V A 8/3W A.C. 250V 6(3)A 2 3 4 VOLT FREE CONTACT CLOSED WHEN DAMPER RELEASED ­ 30...+50 °C CONTINUOUS VOLT FREE CONTACT CLOSED WHEN DAMPER RESET Hot/Shield Vent wiring as above. www.actionair.co.uk 3 Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers Multiple Assemblies Square and rectangular casings are available in multiple module arrangements, supplied complete with blanking strips for site assembly by others. Additional support as well as provision for thermal expansion (4mm/metre) should be allowed for on multiple assemblies. Multiple assemblies require installation approval by the relevant local authority. Installation Frame (Accessory) (as required by HVC 6/5/83) Approximate Weights (Kg) Series 2601 Circular + Installation Frame Series 2501 Square + Installation Frame Series 2601 Circular Series 2501 Square Square or Circular Duct Size (mm) 100 150 200 250 300 Installation frames are delivered to site as a complete assembly with the Hot/Shield PTCTM Damper fitted therein. The frame shall be installed centrally in the thickness of a brickwork or concrete surrounding wall or floor, or in the case of thick walls or floors, so that the centre line of the frame is at least 50mm away from the nearest face of the wall or floor in which the assembly is mounted. The four tabs (building tie) forming each fixing point shall provide a positive fixing into the structure. Multiple assembly dampers up to 1500 x 1500 or 2000 x 1000 can be fitted into fully assembled installation frames and delivered as one piece. Dampers in excess of this size will be supplied in sections with the installation frame supplied in kit-form, AAF Drg.8057. A drawing and method statement will be supplied for the assembly to be fitted on site. The maximum size of kit-form installation frames will be to accommodate a four section assembly. a. In brickwork or blockwork walls the tabs shall be bent out and solidly built into the mortar joints between the brickwork or blockwork. 4 www.actionair.co.uk b. In the case of reinforced concrete walls and floors, the tabs shall be bent out and tied with wire to the reinforcing bars which will be deliberately left protruding into the opening. The gap between the installation frame and builders work shall be backfilled with mortar or concrete on both sides of the flanges. Adjacent frame assemblies must be separated by builders work of a minimum thickness of 225mm (between installation frame upstand flanges) unless approval has been previously obtained from the appropriate Authority. In no case shall the HEVAC/HVCA frame and damper assembly be held in position merely by the adjacent ductwork, and it should be noted that the reinforced concrete structures (especially floors), it will not be sufficient to only backfill between the damper installation frame and the surrounding opening with mortar or fine aggregate concrete mix without provision for tying in the frame to the surrounding reinforced concrete structure. All Fire Damper Installations require relevant local authority approval. 350 400 450 500 550 600 650 700 750 800 850 900 950 3.4 3.4 3.4 4.2 4.8 5.6 6.5 7.4 8.6 9.6 10.8 12.4 13.6 14.9 16.2 17.7 19.2 20.8 6.2 6.2 6.2 7.4 8.7 10.3 11.9 13.2 14.6 16.3 18.5 20.5 22.1 24.0 25.9 28.1 30.3 32.4 34.5 5.3 5.3 5.3 6.1 7.2 8.4 9.6 11.2 12.6 14.0 15.9 17.5 19.1 20.7 22.5 24.3 26.2 29.3 32.1 8.5 8.5 8.5 10.0 11.9 13.7 15.4 17.1 19.2 21.8 24.0 26.0 28.2 30.4 32.8 35.3 37.8 40.3 43.1 1000 23.5 Control Modes 5 & 6 7.6 Kg (including drive interface) Stud Partition Dry Wall Fixing For preferred tested method, please refer to report number 21065 and/or contact our sales office. High Operating Temperature Smoke Management and Fire Dampers Hot/Shield PTCTM Dimensional Data Series 2501 and 3501 (square/rectangular) Duct widths and/or heights between 100mm ­ 175mm, will have nominal damper size of 200mm. Duct widths and/or heights between 176mm ­ 200mm. Please refer to the Actionair Technical Sales Office. Dampers with duct widths and/or heights of between 200mm ­ 1000mm are supplied as nominal damper sizes and without transformation sections. 50 Series 2501 Hot/Shield PTCTM TRANSFORMATION SECTION Series 3501 Hot/Shield Vent PTCTM 25 DUCT WIDTH 100 - 1000 25 90 28 83 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT WIDTH + 116MM DAMPER SPIGOTS 5MM UNDER DUCT SIZE SQUARE OR RECTANGULAR SQUARE OR RECTANGULAR * DUCT HEIGHT 57 * DUCT HEIGHT 100 - 1000 38 38 78 38 38 Dampers with Installation Frames Series 2601 and 3601 (circular) Transformation sections are always included. Dampers with duct diameters between 100mm diameter ­ 150mm diameter, will have nominal damper size of 200mm diameter. Dampers with duct diameters between 151mm diameter ­ 982mm diameter, will have nominal damper size +50mm. Dampers with a nominal damper size between 983mm diameter ­ 1000mm diameter, please refer to the Actionair Technical Sales Office. 25 75 Series 2601 Hot/Shield PTCTM Series 3601 Hot/Shield Vent PTCTM 50 DUCT DIAMETER 100 - 1000 50 90 28 108 25 OVERALL WIDTH OF INSTALLATION FRAME IS DUCT DIA + 166MM DAMPER CIRCULAR SPIGOTS 3MM UNDER DUCT SIZE DUCT DIAMETER CIRCULAR CIRCULAR 100 - 1000 25 82 Series 2701 and 3701 (flat oval) refer to Actionair Sales Office. General All dampers are suitable for both horizontal and vertical application, for airflow in either direction. This information is for guide purposes only, the Actionair Technical Sales Office will provide full dimensional data on request. www.actionair.co.uk All Hot/Shield PTCTM dampers are life safety products and should be treated with care during installation. 50 65 38 78 38 65 25 25 Dampers with Installation Frames 5 Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers. A programme of extensive tests was carried out in the Reverberation Chamber and North Transmission Chamber of Sound research Laboratories Limited, Holbrook Hall, Sudbury, Suffolk, generally in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. This independent test facility is approved under the NAMAS Scheme. From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Table 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Table 2) The graph is the result of a full range of acoustic tests on Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers with the blades set in then fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) is obtained. Example: PRESSURE DROP (Pa) Pressure Drop Vs Velocity 100 90 80 70 60 50 40 30 EXAMPLE LINE Duct with a design velocity of 8 m/sec. Hot/Shield PTCTM Damper Series 2501 fully open. Pressure Drop = 22 Pa (Table 1). Multiply Velocity x Pressure Drop 8 x 22 = 176. From Sound Power Graph (Table 2) plot 176 on horizontal Velocity/Pressure axis against 2501 outlet (induct) graph to obtain 47 dBW on Vertical Sound Power Level Axis. Add or subtract corrections to the 47 dBW to provide full spectrum analysis. 10 9 8 7 6 5 4 3 2 1 1 2 3 4 5 6 7 8 9 10 15 Table 1 VELOCITY (m/s) Damper Leakage Hot/Shield PTCTM and Hot/Shield Vent PTCTM closed blade leakage as tested on a damper 1000mm wide x 1000mm high. Leakage data at Ambient temperature (Cold Smoke). 1500 Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) 90 PRESSURE DIFFERENTIAL ACROSS CLOSED DAMPER (Pa) 80 CT ) 70 26 01 T OU LE T (IN DU 1000 900 800 700 600 500 400 300 SOUND POWER LEVEL (dBW) 60 2 1 50 OU TL E IN T( DU CT ) 200 50 EXAMPLE LINE 40 0 25 1B RE A U KO T 100 90 80 70 60 50 40 30 30 E O AK UT 20 2 1 60 BR 20 10 0 5000 6000 7000 8000 9000 10000 500 600 700 800 900 1000 50 60 70 80 90 100 2000 3000 4000 200 300 400 10 20 30 40 10 5 6 7 8 9 10 20 30 40 50 60 80 100 70 90 Table 2 VELOCITY X PRESSURE DROP (m/s Pa) Table 3 LEAKAGE (I/s) Hot/Shield PTCTM Outlet (Induct) Spectrum Corrections Octave Band63 125 250 500 1k 2k 4k 8k Series 2501 +5 +4 +5 +5 +3 +1 -3 -5 Series 2601 +9 +4 +4 +5 +3 +1 -3 -6 Hot/Shield PTCTM Breakout Spectrum Corrections 63 125 250 500 1k 2k 4k 8k Hz +8 +11 +9 +6 -3 -6 -14 -17 dB +6 +10 +8 +4 -3 -3 -11 -14 dB The leakage as detailed in Table 3 was achieved after a total immersion test at 300 °C for 1 hour (as witnessed by the Loss Prevention Council). 6 www.actionair.co.uk TY PE 25 01 TY PE 26 01 20 High Operating Temperature Smoke Management and Fire Dampers Hot/Shield PTCTM Damper Installation and Control Mode Fitting Dimensional Data 161 411 DAMPER DRIVE SHROUD TRANSIT PLATE 27 snaplockTM RETAINING PIN LOCATION HOLE Series 2501 421 Install the Hot/Shield PTCTM Damper (complete with factory fitted damper shroud and transit plate) into the structure, connect and fit ductwork to damper spigots. Remove transit plate and discard. Slide the snaplockTM drive interface into the damper drive shroud, snaplockTM into position. (Care must be taken when back filling to ensure that the snaplockTM retaining pin location hole and the entry slot of the damper drive shroud is clear of builders work debris). The above dimensional data is for guide/general arrangement purposes. Specification Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers comprising of 75mm stainless steel aerodynamic interlocking blades incorporating synthetic seal, with stainless steel blade end bearings and peripheral gasketing. Housed in a galvanised fully welded, spigotted casing suitable for square, rectangular, circular or flat oval connections. The totally enclosed precise movement opposed blade drive shall be positioned out of the airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplockTM drive interface mechanism, which is totally independent of the ductwork. Hot/Shield PTCTM High Operating Temperature Smoke Management and Fire Dampers in association with their appropriate insulated control modes shall be arranged for motor open and spring closed operation interfaced with a smoke detection/fire alarm system. Hot/Shield PTC Damper and selected thermally insulated Control Modes (HM5, HM5 2H, HM6 and HM6 2H) as supplied by Actionair. Hot/Shield Vent PTCTM High Operating Temperature Smoke Control and Extract Dampers comprising of 75mm stainless steel aerodynamic blades incorporating synthetic seal, with stainless steel blade end bearings and peripheral gasketing. Housed in a galvanised fully welded, spigotted casing suitable for square, rectangular, circular or flat oval connections. The totally enclosed precise movement opposed blade drive shall be positioned out of the airstream for protection against damage, be hard wearing and free running. The Control Mode/Damper connection shall be by means of the snaplockTM drive interface mechanism, which is totally independent of the ductwork. Hot/Shield Vent PTCTM High Operating Temperature Smoke Control and Extract Dampers in association with their appropriate insulated control modes shall be arranged for motor close and spring open operation interfaced with a smoke detection/fire alarm system. Hot/Shield Vent PTCTM Damper and selected thermally insulated Control Modes (HVM5. HM5 2H, HM6 and HVM6 2H) as supplied by Actionair Approvals Heat Degradation test witnessed by the Loss Prevention Council. Complies with the latest DW 144 casing leakage specification. Hot/Shield PTCTM dampers, when closed, are compliant to BS 476 Part 20 Fire Damper Test Standards. The insulated Control Modes satisfy the requirements of EN 50081-1 and EN 50082-1 electro magnetic compatibility. Customer Service Actionair provides quality products backed by a dedicated team committed to providing the very best in customer service. Offering experienced technical backup, comprehensive sales and administrative customer support, product commissioning and maintenance service. The information contained herein is subject to change without notice due to continuing research and development. www.actionair.co.uk 191 7 Hot/Shield PTCTM no compromise... Product Range Smoke/Shield PTCTM Automatic Smoke and Fire Dampers Vent/Shield PTCTM Automatic Smoke Release Dampers Standard Ordering Procedure Please specify Series HS2501/PTC Hot/Shield PTCTM Square or Rectangular (Motor Open/Spring Closure). Hot/Shield PTCTM Circular (Motor Open/Spring Closure). Hot/Shield PTCTM Flat Oval (Motor Open/Spring Closure). HSV3501/PTC Hot/Shield Vent PTCTM Square or Rectangular (Motor Close/Spring Opening). HSV3601/PTC Hot/Shield Vent PTCTM Circular (Motor Close/Spring Opening). HSV3701/PTC Hot/Shield Vent PTCTM Flat Oval (Motor Close/Spring Opening). Hot/Shield PTCTM High Operating Temperature Automatic Smoke and Fire Dampers Hot/Shield Vent PTCTM High Operating Temperature Automatic Smoke Release Dampers Actionpac LNS Addressable Smoke and Fire Damper Control Systems Actionpac EMS and EMB Electro Mechanical Smoke and Fire Damper Control Systems Fire/Shield Stainless Steel Bladed Curtain Fire Dampers Trans/Shield Air Transfer Smoke and Fire Dampers HS2601/PTC HS2701/PTC Accessories Duct Size IF Installation Frame Nominal Damper Spigot Size Control Modes HM5 PTC HM6 PTC HM5 PTC Vent HM6 PTC Vent HM5-2H PTC HM6-2H PTC HM5-2H PTC Vent HM6-2H PTC Vent HM5-3P PTC HM5-3P PTC Vent HM5-2P PTC HM6-2P PTC HM9 PTC Pneumatic HM9 PTC Vent Pneumatic Air/Shield System Air Balancing and Shut-off Dampers Energy/Shield Heavy Duty Air Control and Shut-off Dampers Flame/Shield Adjustable Coated Baffle Grease Filters Access/Shield Removable Hinged Insulated Access Doors For full descriptive list of Control Modes see page 3. Example 5 I Quantity / HS2501 I Series / IF I Accessories / 600(W) x 400(H) I Duct Size / HM6 2H I Control Options Hydropac PHW 230 Horizontal Waterside Control Fan Coil Units Aeropac PHA 230 Horizontal Airside Control Fan Coil Units Hydropac PHW 170 Horizontal Slimline Waterside Control Fan Coil Units Hydropac PVW 230 Vertical Waterside Control Fan Coil Units PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.com Quality System Certificate No 017 Assessed to ISO 9001 Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Part of Ruskin Air Management Limited LNNN00122 - 3/04");sQ1[47]=new Array("http://www.actionair.co.uk/pdf/systempac.pdf","systempac.pdf","","January 2002 Systempac Features and Design Guide Specifically Designed for Design and Build Projects. Complete package including Waterside Control Fan Coil Unit / Controls / Flexible Ducting / Plenum Box / Diffusers. Choice of Linear Slot Diffusers or 4 Way Throw Louvred-Faced Diffusers. Available in three thermal outputs 2kW / 3kW / 4kW sensible cooling and heating. Fully acoustically and thermally tested. Quick and simple design selection. Customer friendly installation and commissioning. Competitive priced solutions with fastrack delivery. Systempac Fan Coil Unit / Acoustic Flex / Diffuser System Package Systempac Product Specification Fan Coil Unit Waterside Control 230mm deep horizontal draw through chassis type Fan Coil Units. Chassis constructed from 1.2mm galvanised sheet steel, with 1.6mm fan deck and back plates. The flush external finish prevents exposure to bare edges and incorporates recessed, reinforced slotted mounting points for ease of installation. Access to fans/motors is via an insulated bottom panel with keyslots for accurate positioning and easy removal. The thermal and acoustic insulation is 100 kg/m3 density, class `O' CFC and HFC free open cell foam and complies with `Section 20' requirements. External condensate tray insulation is similar in specification, but closed cell type. Fans are double inlet, resiliently mounted direct driven, forward curved centrifugal type and are mounted on an easily removable deck. The motors are permanent split capacitor type external rotor, totally enclosed, speed controllable. A ventilated controls housing mounted on the same side as the control valves, includes a hinged removable cover, three speed selector switch and illuminated on/off switch. Coil matrix blocks are manufactured from seamless copper tube mechanically expanded into aluminium fins having die formed collars, providing a tight bond to optimise heat transfer. Vents and drains are fitted as standard with easily accessible slotted / hexagonal plugs. Coils are pressure tested using dry air under water to 15 bar. Filters are washable EU3 continuous filament filter media to Eurovent 4/5, with F1 fire resistance to DIN 53438 and a dust holding capacity of 380g/m2. Condensate trays are one piece, welded, galvanised sheet steel, synthetically treated, foam insulated and extended to cover the entire coil and valve assembly and can be easily removed for cleaning / maintenance. The tray has a positive fall to drain with a BSP female connection fitted at the lowest point, on the underside. digital unit, mounted on the outside of the fan coil controls enclosure. The T8078B1027 is designed for individual zone temperature management, but can accept remote set point adjustment from Flexibility Each diffuser is 1195mm x 179mm overall size including end flanges, which can either lay-in or fit below a grid, or be second fixed into a plaster margin. Plenum Box Each diffuser is supplied with a galvanised sheet steel plenum box complete with both 198mm diameter side entry spigot and cord operated damper allowing adjustment from the diffuser face. Easy Fixing Each diffuser is complete with `U' bracket fixings which enable the installer to simply second fix the diffuser within the ceiling. This method is particularly useful when diffusers have to be installed in a ceiling with limited access. Louvred-Faced (LF) Diffusers and Plenum Boxes The louvred-faced diffusers are manufactured from extruded aluminium profiles and offer exceptional performance from a 4 way removable core. All diffusers are finished in RAL9010 Eggshell White power coat. Flexibility The 373mm x 373mm overall size square diffuser can be accommodated within almost all types of ceiling systems. Installation Option Should the installer prefer not to cut a diffuser into a tile, then a 595mm x 595mm overall diffuser can be ordered which simply lays within the ceiling grid. Plenum Box Each diffuser is supplied with a galvanised sheet steel plenum box complete with both 198mm diameter side entry spigot and cord operated damper allowing adjustment from the diffuser face. Easy Fixing Both the 373mm and 595mm overall diffusers are complete with removable cores, which enable the installer to secretly fix by means of either rivet or PK screw. a BMS. The unit provides proportional plus integral (P+I) control of valve/actuators to regulate heating and cooling output. The control has a self calibrating and commissioning function to ensure correct synchronisation of valve/actuators is always maintained. (9 minute test cycle). A remote sensor (encapsulated silicon type) is fitted to the inlet of the fancoil unit after the filter and wired to the T8078B with a 1.5m flying lead. Honeywell 4 port valves with 24 Volt modulating actuators are fitted and wired to both the heating and cooling coils with compression fitting and hydraulically tested to 10 bar. Optional remote temperature sensor and setpoint adjuster are also available. Acoustic Flex 1 metre of 200mm diameter Sonodec25 acoustic flexible ducting is supplied for each outlet spigot. Sonodec25 is insulated both acoustically and thermally. The inner duct is micro-perforated aluminium / polyester flexible with steel spring coil. This is insulated with 25mm fibreglass having a density of 16 kg/m3. It is completely enclosed in a seamless fibreglass reinforced aluminium outer duct. A polyester barrier is applied between the micro-perforated inner duct and the fibreglass, to prevent ingress of the fibreglass into the airstream. The flex conforms to BS476 parts 6, 7 and 20. Two 'Zip tie' clips are supplied for each discharge duct. Diffusers Linear Slot Diffusers (LS) and Plenum Boxes The 3 slot linear diffuser offers both unobtrusive good looks with functional efficiency and are fully adjustable giving both horizontal and vertical projection. Slot diffusers are manufactured from high quality extruded aluminium sections and come with RAL9010 Eggshell White powder coat frames and Black internal components/blades as standard. Controls The controller is a Honeywell T8078B1027 24 Volt non-addressable 2 Systempac Unit Selection Data Package Reference SP2-LS/LF SP2-LS/LF SP2-LS/LF Speed Setting I II III Room NR 35 38 40 Total Air Volume (l/s) 150 170 190 Sensible Cooling (kW) 1.5 2.0 2.4 Total Cooling (kW) 1.6 2.2 2.4 Air Off (°C DB) 14.6 13.2 12.7 CHW Flowrate (l/s) 0.08 0.10 0.12 Coil + Valve (kPa) 12.4 19.6 27.9 Heating Duty (kW) 1.5 2.0 2.5 Air Off (°C) 28.3 29.8 31.0 LTHW Flowrate (l/s) 0.03 0.04 0.06 Coil + Valve (kPa) 3.3 4.4 9.2 Input Watts 70 90 110 Numbers of Outlets 2 2 2 SP3-LS/LF SP3-LS/LF SP3-LS/LF I II III 35 38 40 205 225 250 2.5 3.0 3.3 2.8 3.6 3.8 12.8 12.0 12.1 0.13 0.17 0.18 14.8 33.8 36.3 2.5 3.0 3.5 30.2 32.1 32.7 0.06 0.07 0.08 2.9 4.3 5.1 110 160 180 3 3 3 SP4X-LS/LF SP4X-LS/LF SP4X-LS/LF I II III 35 38 40 270 305 340 3.6 4.0 4.3 3.9 4.5 4.7 12.2 12.3 12.6 0.19 0.21 0.22 31.0 42.0 43.0 3.5 4.0 4.3 30.8 30.7 31.3 0.08 0.09 0.10 5.2 6.6 8.3 200 220 240 4 4 4 The Fan Coil selections are based on: Cooling: Summer On-coil air 23 °C Dry Bulb, 16 °C Wet Bulb. Chilled Water flow temperature 6 °C. Chilled Water return temperature 11 °C. Heating: Winter On-coil air temperature 20 °C Dry Bulb. LTHW flow temperature 82 °C. LTHW return temperature 71 °C. General: External Resistance 15pa. Electrical Supply 230 Volts/ 1 phase /50 Hz. The following refers to specific diffuser performance:­ Type LS ­ Linear Slot Diffuser Fully adjustable Linear Slot Diffusers with both horizontal and vertical projection. Throw data is based upon a temperature differential of 10 °C cooling to terminal velocity of 0.25 m/s for 1150mm active length with a room height of 2.7m, when mounted flush with an unobstructed flat ceiling. Package Reference SP2-LS Speed Setting I II III I II III I II III Total Air Volume per Package (l/s) 150 170 190 205 225 250 270 305 340 Slot Diffusers Supplied as Standard 2 x 1195 long Plenum Boxes Supplied as Standard 2 x 1145 long Volumetric Flow Rate (l/s per m) 66 74 83 60 66 73 59 66 74 Throw (m) 3.0 3.4 4.3 2.2 3.0 3.4 2.2 3.0 3.4 SP3-LS 3 x 1195 long 3 x 1145 long SP4X-LS 4 x 1195 long 4 x 1145 long Type LF ­ Louvre-Faced Diffuser 4 Way Louvred-Faced Diffuser (horizontal diffusion), 225mm x 225mm neck size. Throw data is based on a temperature differential of 10 °C cooling to a terminal velocity of 0.5 m/s to give average room velocity of 0.18 m/s with a room height of 2.7m, when mounted flush with an unobstructed flat ceiling. Package Reference SP2-LF Speed Setting I II III I II III I II III Total Air Volume per Package (l/s) 150 170 190 205 225 250 270 305 340 Number of Diffusers per Package 2 Air Volume per Diffuser (l/s) 75 85 95 68 75 92 68 76 85 Throw Based upon 4 Way Diffuser (m) 1.8 2.0 2.2 1.6 1.8 2.1 1.6 1.8 2.0 SP3-LF 3 SP4X-LF 4 3 Systempac Acoustic Performance Data Typical Horizontal Fan Coil Unit Arrangement FRESH AIR SUPPLY DUCT FAN COIL UNIT MINIMUM 1 METRE LENGTH SONODEC 25 ACOUSTIC FLEX DIFFUSER PLENUM CONCRETE 1.5 metres WALL/GLAZING RETURN AIR GRILLE/DIFFUSER (NOT POSITIONED DIRECTLY BELOW UNIT INTAKES) All associated components have to be be mounted in accordance with manufacturer instructions. The fan coil units must be mounted within a false ceiling void of not less than 300mm deep. The false ceiling should be constructed of standard 10mm thick fibre tiles or metal pan tiles with a 15mm acoustic backing. Rooms of open plan or partitioned design have to be be furnished, carpeted and have no more than 20% glass area with no highly T BAR GRID FALSE CEILING WITH EITHER 10mm THICK FIBRE BOARD TILES OR METAL PAN TILES reflective surfaces such as ceramic tiles etc. Where a single package is serving a room the dimensions should be based upon a cooling load of 0.12 kW per m 2. In an open plan area units should be mounted at a minimum of 4.5m centres and no closer than 1.5m from a corner. Retur n air grilles / diffusers (not included within the package, but can be supplied as an optional extra cost item) should be positioned at least 1.5m from the fan coil unit INTERNAL ROOM intake. A 1m active length of Sonodec25 acoustic flexible ducting is supplied and must be fitted to each fan coil outlet. The remainder of interconnecting ductwork can comprise up to 3m of rigid spiral ductwork (including one ­ 90 degree bend) or up to 2m additional flexible ducting, on each spigot (supplied by others). For further information a full acoustic report is available on request. Installation Units should be positioned so that access is available for routine maintenance and removal of coils, fans, filters and to open the controls enclosure. All units must be installed in accordance with good engineering standards and due care and attention to eliminate any possible damage. The installation must ensure level positioning to facilitate correct operation and condensate removal. The recommended method of unit 4 suspension (see below) is by means of M10 studding (supplied by others). The accessory pack includes 3mm rubber washers and large supporting washers. All connecting metal ductwork must be supported independently of the fan coil unit spigot connections, in accordance with DW 144. All wiring must comply with all relevant British Standard Codes of Practice and good engineering principles. Drain tray connection fittings should not protrude above the level of the tray to avoid condensate to be held back in the tray. Please refer to the full operation and maintenance instructions prior to installation. Systempac Type LS Linear Slot Diffuser Option Cord operated Damper 20 1 No. 8mm hole each end for suspension 300 ø1 98 32 25 20 179 (Overall) 1165 Ceiling opening 151 200 1145 (Inside) 179 160 32 1195 (Overall) Cord operated Damper Ceiling opening Type LF Louvred-Faced Diffuser Option B A 8mm holes for suspension 20 300 ø1 98 32 C (Overall) Dimensions Type LF3 LF6 A 225 447 B 298 520 C 373 595 D 225 447 E 225 447 All dimensions shown are in mm. 5 D (Inside) 200 E (Inside) Systempac Fan Coil Dimensions SP2 REMOVABLE FILTER RETURN Unit SP2 Weight 35kg HTG Conns ø15mm CLG Conns ø15mm FLOW CONTROL ENCLOSURE VALVE FIXING CENTRES 726 276 50 120 290 FIXING CENTRES 160 104 40 66 95 540 100 KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION DIRECTION OF AIR FLOW LHS 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) 700 15 (FIXING CENTRES) HTG INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED 230 730 200 50 CLG DRAIN CENTRE LINE 45 Ø 197 SPIGOTS SP3 REMOVABLE FILTER RETURN Unit SP3 CONTROL ENCLOSURE 115 115 Weight 50kg HTG Conns ø15mm VALVE FIXING CENTRES CLG Conns ø22mm FLOW DIRECTION OF AIR FLOW LHS 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) 50 726 276 120 290 FIXING CENTRES 160 104 40 66 95 540 100 KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION 1050 15 (FIXING CENTRES) HTG INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED 230 1080 200 50 CLG DRAIN CENTRE LINE 540 350 45 Ø 197 SPIGOTS SP4X REMOVABLE FILTER RETURN Unit SP4X 115 115 Weight 70kg HTG Conns ø15mm VALVE FIXING CENTRES CLG Conns ø22mm FLOW CONTROL ENCLOSURE DIRECTION OF AIR FLOW LHS 4 No. RAPID POSITION FIXING SLOTS (TO SUIT M10 STUDING) 50 726 276 120 290 FIXING CENTRES 160 104 40 66 95 540 100 KEYHOLE REMOVABLE ACCESS PANEL 3/4 INCH FEMALE BSP DRAIN CONNECTION 230 1430 1400 15 (FIXING CENTRES) 200 50 INSULATED COVER PLATE FITTED WHERE SPIGOT IS NOT PROVIDED HTG CLG DRAIN CENTRE LINE 540 350 350 45 Ø 197 SPIGOTS 6 115 115 Systempac Type LS Linear Slot Diffuser Option LINEAR SLOT DIFFUSER (LS) PLENUM BOXES SONODEC 25 ACOUSTIC FLEX SP3 FANCOIL UNIT Type LF Louvred-Faced Diffuser Option SONODEC 25 ACOUSTIC FLEX 4 WAY LOUVRED FACE DIFFUSER (LF6) SP3 FANCOIL UNIT 7 Systempac www.air-diffusion.co.uk w w w . a c t i o n a i r . c o . u k Ordering Procedure LS Range Reference - SP2-LS Systempac is available in 9 packages 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:2 ­ 3 Slot Linear Diffusers (1195mm long), 2 ­ Plenum Boxes 1 ­ 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 3kW Thermal Output: 1 Size 3 Fan Coil Unit including:3 ­ 3 Slot Linear Diffusers (1195mm long), 3 ­ Plenum Boxes 1 ­ 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 4kW Thermal Output: 1 Size 4x Fan Coil Unit including:4 ­ 3 Slot Linear Diffusers (1195mm Long), 4 ­ Plenum Boxes 1 ­ 4m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack Reference - SP3-LS Reference - SP4X-LS LF3 Range Reference - SP2-LF3 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:2 ­ 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 2 ­ Plenum Boxes 1 ­ 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 3kW Thermal Output: 1 Size 3 Fan Coil Unit including:3 ­ 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 3 ­ Plenum Boxes 1 ­ 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 4kW Thermal Output: 1 Size 4X Fan Coil Unit including:4 ­ 4 Way Louvred-Faced Diffusers (373 x 373mm O/A), 4 ­ Plenum Boxes 1 ­ 4m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack Reference - SP3-LF3 Reference - SP4X-LF3 LF6 Range Reference - SP2-LF6 2kW Thermal Output: 1 Size 2 Fan Coil Unit including:2 ­ 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 2 ­ Plenum Boxes 1 ­ 2m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 3kW Thermal Output / 1 Size 3 Fan Coil Unit including:3 ­ 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 3 ­ Plenum Boxes 1 ­ 3m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack 4kW Thermal Output / 1 Size 4X Fan Coil Unit including:4 ­ 4 Way Louvred-Faced Diffusers (595 x 595mm Overall*), 4 ­ Plenum Boxes 1 ­ 4m minimum length of Acoustic Flexible Ducting (200mm diameter) 1 - Accessory pack Reference - SP3-LF6 Reference - SP4X-LF6 *225 x 225 active Please Note: All handings for pipework / controls are left hand only. Packages detailed include components as listed, refer to individual product specifications as detailed on page 2. Systempac data is based upon the design data as detailed on pages 3 and 4. Any deviation will result in differing thermal / volumetric / acoustic performance characteristics. Please specify Systempac reference (e.g. SP4X-LS) and package quantity required. Optional extra cost items are available, please contact our Customer Service Offices. P l e a s e refer to our websites for current prices or contact either Customer Service Office Actionair, South Street, Whitstable, Kent CT5 3DU England Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk Unit 10 Sutherland Court, Brownfields Welwyn Garden City, Herts, AL7 1AN Tel: 0845 095 1212 Fax: (01707) 294170 International Code: +441707 Email: sales@air-diffusion.co.uk Website: www.air-diffusion.co.uk Quality System Certificate No 017 Assessed to ISO 9002 PRODUCED BY GRAPHIC PARTNERSHIP www.graphicpartnership.co.uk Optional Extras A. Remote room mounted set point adjuster / temperature sensor ( fitted by others). B. Additional 10m lengths of Sonodec25 acoustic flex. C. Return air packages using any of the diffusers shown above.");sQ1[48]=new Array("http://www.actionair.co.uk/la.html","Actionair Sales Representative Les Atkinson","","Home Actionair Sales Representation Actionair sales area manager - Les Atkinson SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 33 LANCASHIRE MERSEYSIDE GREATER MANCHESTER CHESHIRE CLWYD(DENBITH &amp; FLINT) GWYNEDD(MERIONETH, CAERNARVON &amp; ANGLESEY) DERBYSHIRE (EXCLUDING CHESTERFIELD) LES ATKINSON AREA SALES MANAGER MOBILE TEL : 07710 601523  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[49]=new Array("http://www.actionair.co.uk/tb.html","Actionair Sales Representative Trevor Bradley","","Home Actionair Sales Representation Actionair sales area manager - Trevor Bradley SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 31 WEST MIDLANDS WARWICKSHIRE WORCESTERSHIRE HEREFORDSHIRE STAFFORDSHIRE SHROPSIRE OXFORDSHIRE BIRMINGHAM LEICESTERSHIRE NORTHAMPTONSHIRE TREVOR BRADLEY AREA SALES MANAGER MOBILE TEL : 07710 601527  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[50]=new Array("http://www.actionair.co.uk/kl.html","Actionair Sales Manager Keith Lander","","Home Actionair Sales Representation Actionair sales area manager - Keith Lander SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 24 LONDON SW1-SW3, SW7-SW20 EAST SUSSEX WEST SUSSEX DORSET HAMPSHIRE SURREY KEITH LANDER AREA SALES MANAGER MOBILE TEL : 07710 601524  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[51]=new Array("http://www.actionair.co.uk/dl.html","Actionair Sales Manager Dave Leek","","Home Actionair Sales Representation Actionair sales area manager - Dave Leek SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 26 GLAMORGAN (MID, SOUTH WEST) GWENT (MONMOUTH) DYFED (CARDIGAN, CARMARTHEN, &amp; PEMBROKE) POWYS (BRECON, RADNOR &amp; MONTGOMERY) GLOUCESTERSHIRE AVON WILTSHIRE SOMERSET DEVON &amp; CORNWALL DAVE LEEK AREA SALES MANAGER MOBILE TEL : 07710 601530  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[52]=new Array("http://www.actionair.co.uk/jw.html","Actionair Sales Representative John Webber","","Home Actionair Sales Representation Actionair sales area manager - John Webber SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 21 LONDON EC1-EC4, N1-N22, NW1-NW11, SE1-SE28, SE99, W1-W13, WC1-WC2 MIDDLESEX HERTFORDSHIRE BERKSHIRE BEDFORDSHIRE BUCKINGHAMSHIRE JOHN WEBBER AREA SALES MANAGER MOBILE TEL : 0410 601526  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[53]=new Array("http://www.actionair.co.uk/intersales.html","Actionair International Sales Agents Map","","Home Actionair Sales Representation Actionair International Sales Please select the relevant Agent location below from the International Sales Map:  Actionair International Sales GRAHAM COOPER Mobile : 07710601515   Actionair Sales Office, Joseph Wilson Ind. Estate, South Street, Whitstable, Kent CT5 3DU United Kingdom Tel: (01227) 276100 Fax: (01227) 264262 International Code: +441227 Email: sales@actionair.co.uk Website: www.actionair.co.uk ALLAN AGATE EMPHASIS ON GLASS LOUVRES MOBILE : 07970 231644&quot; alt=&quot;Mike Warnock EMPHASIS ON METAL LOUVRES MOBILE : 07970 231650 ALLAN AGATE EMPHASIS ON GLASS LOUVRES MOBILE : 07970 231644&quot; &gt; Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2007 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[54]=new Array("http://www.actionair.co.uk/gc.html","Actionair Export Sales Manager Graham Cooper","","Home Actionair Sales Representation Actionair Sales Representation Export sales manager - Graham Cooper SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE N/A GRAHAM COOPER EXPORT SALES MANAGER MOBILE TEL : 07710 601515  International Exhibitions Attended The 44th International Boat Show Genova  The 2004 METS show in Amsterdam (Marine Engineering Equipment Show)  Product Demonstrated Actionair A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects  Product Demonstrated Mist Separator Air intake mist separator The 44th International Boat Show recorded an overall number of 326 thousand visitors. The organisers - Fiera di Genova SpA and UCINA - expressed their great satisfaction with the level reached by the Show, which constantly aims at generating new business - the turnover was one billion Euros - and increasing its appeal, through a wide range of products on display and a calendar of side events capable of attracting a higher and higher number of people to the world of pleasure boating. Some figures clearly highlight the importance of Genoa Boat Show: 1,547 exhibitors were present, over a 288 thousand-square-metre exhibition area; there were 1,987 boats on display, 201 of which in the water in the two equipped marinas, the basins, and at Yacht Club Italiano. Genoa forty fifth International Boat Show will be held from 8 through 16 October 2005.  Graham Cooper at the METS (Marine Equipment Trade Show) - held at the magnificently appointed RAI Centre in Amsterdam and ran from November 15th to 17th. Graham commented, &#8216;&#8216;Yet another successful show and a smashing shop window for our products&#8221;.    Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence.  Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[55]=new Array("http://www.actionair.co.uk/int8.htm","International Sales Representation - Austria &amp; Republic of Slovenia","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 800 AUSTRIA REPUBLIC OF SLOVENIA MECKE KLIMA GMBH UNGARGASSE 46 1030 WIEN AUSTRIA ACTUAL TIME GMT + 1 HR TEL NUM 00 43 1 713 3783 FAX NUM 00 43 1 713 8636 EMAIL office@meckeklima.at WEBSITE N/A PERSONNEL C MECKE G DEIFEL M BRAUN Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[56]=new Array("http://www.actionair.co.uk/int3.htm","International Sales Representation - Denmark","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 880 DENMARK Gugliotta & Co Aavaeget 11, Morgestrup DK-4700 Naestved DENMARK ACTUAL TIME GMT + 1 HR TEL NUM 0045 55 71 11 10 FAX NUM 0045 55 71 11 12 EMAIL diego@gugliotta.net WEBSITE www.gugliotta.com PERSONNEL Diego Gugliotta Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[57]=new Array("http://www.actionair.co.uk/int4.htm","International Sales Representation - Norway","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 875 NORWAY BVS Brannvernsystemer AS RYFYLKEGATEN 22 N-4014 STAVANGER NORWAY ACTUAL TIME GMT + 1 HR TEL NUM 00 4751547200 FAX NUM 00 47 51547202 EMAIL See Below Please WEBSITE www.brannvernsystemer.no PERSONNEL Frank Hinrichsen - General Manager (Head Office) Tel: +47 51547200 Fax +47 51547202 frank@brannvernsystemer.no Thore Thomassen - Manager Shipping (Shipping Department) Tel: +47 90042414 Fax +471547202 thore.thomassen@brannvernsystemer.no Holger Hinrichsen - Country Manager (Plant Hamburg-Germany) Tel: +49 40 525 66 33 Fax +49 40 5251010 holger.hinrichsen@brannvernsystemer.no Jan Ove Søgård - Regional Manager (Department Oslo) Tel: +47 97721635 Fax +47 51547202 janove@brannvernsystemer.no Jan Hantho - Regional Manager (Department Haugesund) Tel: +47 98242800 Fax +47 51547202 jan@hbas.no Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[58]=new Array("http://www.actionair.co.uk/int5.htm","International Sales Representation - Netherlands","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 840 NETHERLANDS SCHILT LUCHTTECHNIEK BV ATT. RODACO ENERGLEWEG 29 4231 DJ MEERKERK THE NETHERLANDS ACTUAL TIME GMT + 1 HR TEL NUM 0031 183 35 24 44 FAX NUM 0031 183 35 23 13 EMAIL info@schilt-meerkerk.nl WEBSITE www.schilt-meerkerk.nl PERSONNEL A.L. 't Jong Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[59]=new Array("http://www.actionair.co.uk/int6.htm","International Sales Representation - Sweden","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 850 SWEDEN SCANDFILTER AB BOX 202 S - 512 SVENLJUNGA SWEDEN ACTUAL TIME GMT + 1 HR TEL NUM 00 46 325 126 80 FAX NUM 00 46 325 11490 EMAIL N/A WEBSITE N/A PERSONNEL BO LINDVERT H ULLEGAARD R OHLANDER A HAKANSSON U SALL Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[60]=new Array("http://www.actionair.co.uk/int7.htm","International Sales Representation - Portugal","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 850 PORTUGAL DECFLEX R. VELOSO SALGADO, 1104 * 4450 - 801 LECA DA PALMEIRA, PORTUGAL ACTUAL TIME GMT + 1 HR TEL NUM 00 351 22 999 11 00 FAX NUM 00 351 22 999 11 19 EMAIL geral@decflex.com WEBSITE www.decflex.com PERSONNEL MR LUIZ ARAUJO Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[61]=new Array("http://www.actionair.co.uk/int9.htm","International Sales Representation - Switzerland","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVE 870 SWITZERLAND RONAIR AG WITELLIKERSTRASSE 23 POSTFACH 46 CH 8702 ZOLLIKON ZH ZURICH SWITZERLAND ACTUAL TIME GMT + 1 HR TEL NUM 00 411 391 33 44 FAX NUM 00 411 391 26 77 EMAIL N/A WEBSITE N/A PERSONNEL M ROHNER Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[62]=new Array("http://www.actionair.co.uk/int10.htm","Actionair International Sales Representation - BELGIUM &amp; LUXEMBOURG","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 805 BELGIUM LUXEMBOURG RUCON VENTILATOREN NV HESTSTRAAT 49/4 2630 AARTSELAAR ANTWERP BELGIUM ACTUAL TIME GMT + 1HR TEL NUM 00 32 3 877 0776 FAX NUM 00 32 3 877 0857 EMAIL N/A WEBSITE N/A PERSONNEL A RAENDERS J DE BRUYN Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[63]=new Array("http://www.actionair.co.uk/int12.htm","Actionair International Sales Representation - TURKEY","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 815 TURKEY ATC. AIR TRADE CENTRE IBRAHIM KARAOGLANOGLU CADDESI NO: 101 34418 SEYRANTEPE ISTANBUL TURKEY ACTUAL TIME GMT + 2HR TEL NUM 00 90 212 287 7034 FAX NUM 00 90 212 287 7037 EMAIL dec@iris.com.tr WEBSITE N/A PERSONNEL A ALTUNKESER B KARAGOZOGLU SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 815 TURKEY DERYA MARINE SARIANA MH.27, SK.NO:2/3 48700 MARMARIS TURKEY TEL NUM 1 00 90252 4125225 TEL NUM 2 00 90252 4132479 FAX NUM 00 90252 4136630 MOBILE 00 90532 6502687 EMAIL deryamarine@superonline.com WEBSITE N/A PERSONNEL PHILIPPE BOISVIEUX Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[64]=new Array("http://www.actionair.co.uk/int13.htm","Actionair International Sales Representation - UNITED ARAB EMIRATES","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 960 UNITED ARAB EMIRATES GULF ACCOUSTICS LLC POST BOX 12150 DUBAI UNITED ARAB EMIRATES ACTUAL TIME GMT + 4HR TEL NUM 00 971 4 3477937 FAX NUM 00 971 4 3477232 EMAIL pansonjv@emirates.net.ae WEBSITE N/A PERSONNEL R GRATTON RAJESH Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[65]=new Array("http://www.actionair.co.uk/int14.htm","Actionair International Sales Representation - POLAND","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 960 POLAND MERCOR SP Z.O.O UL GRZEGORZA Z SANOKA 2 80 - 408 GDANSK POLAND ACTUAL TIME GMT + 2HR TEL NUM 00 48 583 414245 FAX NUM 00 48 583 413985 EMAIL mercor@mercor.com.pl WEBSITE N/A PERSONNEL MR M POPINIGIS MISS K KHLOPECK MISS P PROTASIEWICZ RADOMIR SPIOLEC Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[66]=new Array("http://www.actionair.co.uk/int15.htm","Actionair International Sales Representation - CHINA, HONG KONG &amp; MACAU","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 900 CHINA, HONG KONG &amp; MACAU  STAR GLORY TECH LTD ROOM 1702, 17TH FLOOR, NO. 41-47, MARBLE ROAD, NORTH POINT HONG KONG ACTUAL TIME GMT + 8HR TEL NUM 00852 34275028 FAX NUM 00852 21465050 EMAIL info@starglory.net WEBSITE N/A PERSONNEL PAUL CHAN Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[67]=new Array("http://www.actionair.co.uk/int16.htm","Actionair International Sales Representation - BAHRAIN","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 955 BAHRAIN KHAYBER TRADING COMPANY PO BOX 1976 MANAMA BAHRAIN ACTUAL TIME GMT + 3HR TEL NUM00357 2 492775 00 973 720747 FAX NUM 00 973 720331 EMAIL khayber@batelco.com.bh WEBSITE N/A PERSONNEL M KARAOLIS B OXFORD Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[68]=new Array("http://www.actionair.co.uk/int17.htm","Actionair International Sales Representation - SINGAPORE","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 905 SINGAPORE COLT VENTILATION EAST ASIA PTE LTD 4 LENG KEE ROAD 03-11 SIS BUILDING SINGAPORE 159088 ACTUAL TIME GMT + 7HR TEL NUM00357 2 492775 00 65 250 1581 FAX NUM 00 65 250 2334 EMAIL coltsales@pacific.net.sg WEBSITE www.coltgroup.com PERSONNEL MATTHEW SIMM KEITH RICKINSON Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[69]=new Array("http://www.actionair.co.uk/int18.htm","Actionair International Sales Representation - OMAN","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 925 OMAN MOHSIN HAIDER DARWISH COMMERCIAL HVAC DEPT PO BOX 880 RUWI SULTANATE OF OMAN ACTUAL TIME GMT + 4HR TEL NUM00357 2 492775 00 968 703777 FAX NUM 00 968 793256 EMAIL N/A WEBSITE N/A PERSONNEL S SANGHAVI J JACOB Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[70]=new Array("http://www.actionair.co.uk/int19.htm","Actionair International Sales Representation - MALAYSIA","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 910 MALAYSIA FITTERS SDN BHD BANGUNAN FITTERS LOT 2221, KG.JAYA INDUST EST SG. BULOH 47000 SELANGOR DARUL ESHSAN MALAYSIA ACTUAL TIME GMT + 8HR TEL NUM00357 2 492775 00603 657266 FAX NUM 00603 657146 or 00603 657 6720 EMAIL N/A WEBSITE N/A PERSONNEL R GOH Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[71]=new Array("http://www.actionair.co.uk/int20.htm","Actionair International Sales Representation - SOUTH KOREA","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 933 SOUTH KOREA DONG YANG AIR CONDITIONING LTD 206-1 ANYANG - 7 DONG MANANKU ANYANG CITY KYUNGGIDO SOUTH KOREA ACTUAL TIME GMT + 9HR TEL NUM00357 2 492775 0082 343 69 2268 FAX NUM 0082 343 69 2269 EMAIL N/A WEBSITE N/A PERSONNEL YOUNG - YUL CHOI SANG-HAE PARK Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[72]=new Array("http://www.actionair.co.uk/int21.htm","Actionair International Sales Representation - QATAR","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 930 QATAR DARWISH TRADING AIR CONDITIONING DIVISION PO BOX 82 DOHA QATAR ACTUAL TIME GMT + 3HR TEL NUM00357 2 492775 00 974 4422781 FAX NUM 00 974 4417599 EMAIL dtemain@qatar.net.qa WEBSITE N/A PERSONNEL J S ASHAI A SHAH J JACOB N HOSSEIN Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[73]=new Array("http://www.actionair.co.uk/int22.htm","Actionair International Sales Representation - CYPRUS","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 860 CYPRUS NIANPA (PATATOS) LTD P.O. BOX 25528 54A, 28TH OCTOBER AVENUE 2414 MAKEDONITISSA NICOSIA CYPRUS ACTUAL TIME GMT + 2HR TEL NUM 00357 22 353 808 FAX NUM 00357 22 353 173 EMAIL nianpa@cytanet.com.cy WEBSITE www.nianpa.com PERSONNEL PANTELIS PATATOS, MD PANAGIOTIS FARMAKIS, Sales Manager Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[74]=new Array("http://www.actionair.co.uk/int23.htm","Actionair International Sales Representation - GREECE","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 860 GREECE AIRLEX HELLAS S.A. 108 ANDREA PAPANDREOU ST GR 166 74 ATHENS GREECE ACTUAL TIME GMT + 2HR TEL NUM 00 301 965 0850 FAX NUM 00 301 965 0755 EMAIL N/A WEBSITE N/A PERSONNEL LEONIDIS DOURIDAS NIKOS SALMATANIS Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2008 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[75]=new Array("http://www.actionair.co.uk/int24.htm","International Sales Representation - CATEF SRL - ITALY","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 830 ITALY CATEF SRL Via dei Lecci, 145 55049 Viareggio (LU) Italy Tel: +39 0584 390609 - Fax: +39 0584 397752 Office and Workshop Via Grecale, 33 55049 Viareggio (LU) Italy Global supplier of fire protection system to the marine industry CATEF srl is a major supplier of fire safety systems and accessories to the global maritime and off-shore market. With more than 30 years experience CATEF (and its product division Estintori Cassiano) delivers the most reliable and competitive fire extinguishing and fire detection systems. Situated in Viareggio - the heart of the Italian yacht building industry - CATEF is a long-time supplier to all the key national boatbuilders and has in recent years been expanding with unqualified success into the international market. Our systems meet the highest standard requirements of all major classification societies and customer expectations. CATEF srl can provide fire protection systems incorporating all the recognised fire extinguishing agents, e.g.: Clean Agent pre-engineered and engineered fire suppression systems: FM200 , FE-227 , FE-25 , NOVEC CO2 engineered fire suppression systems and CO2 portable fire extinguishers Dry Powder portable extinguishers and Dry Powder piped pre-engineered systems; Wet Chemical Extinguishers for Class F (oil) fires Water Mist for accommodation, public areas, high risk and total flooding Foam high and low expansion fire extinguishing systems for engine rooms, pump rooms and ro-ro spaces. CATEF srl also supplies a full range of fire alarm and smoke detection systems, Marine Fire Dampers (A-60), Shut-off Dampers and Mist Eliminators. ACTUAL TIME GMT + 1HR TEL NUM 0039 0584 390 609 FAX NUM 0039 0584 397 752 EMAIL FOR INFORMATION: info@marine-fire.com FOR SALE DEPARTMENT: sales@marine-fire.com WEBSITE http://www.marine-fire.com/ PERSONNEL JACAPO CASSIANO Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[76]=new Array("http://www.actionair.co.uk/int25.htm","International Sales Representation - LEBANON","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 915 LEBANON THERMOTRADE S.A.L. CITY STADIUM BUILDING NAOUS DALAME CTR P O BOX 155156 BEIRUT LEBANON ACTUAL TIME GMT + 2HR TEL NUM 00 9611 841 065 FAX NUM 00 9611 871 060 EMAIL N/A WEBSITE N/A PERSONNEL SAMIR TRABOULSI Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[77]=new Array("http://www.actionair.co.uk/int26.htm","International Sales Representation - EGYPT","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 894 EGYPT MINTA 21 AL ALFY ST CITY CENTRE 11111 ATABA CAIRO EGYPT ACTUAL TIME GMT + 2HR TEL NUM 00 202 02591 3992 FAX NUM N/A EMAIL N/A WEBSITE N/A PERSONNEL MAHMOUD BIALI MAHMOUD ADEL DALIA Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[78]=new Array("http://www.actionair.co.uk/int2.htm","International Sales Representation - REPUBLIC OF","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 820 REPUBLIC OF IRELAND SAFEGARD SYSTEMS SYSTEMS HOUSE UNIT 34 SOUTHER CROSS BUSINESS PARK BRAY COUNTY WICKLOW IRELAND ACTUAL TIME GMT TEL NUM 00353 1 276 1600 FAX NUM 00353 1 276 1611 EMAIL INFO@SAFEGARD.IE WEBSITE www.safegard.ie PERSONNEL Connor Walsh SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 820 REPUBLIC OF IRELAND VENTAC &amp; COMPANY LIMITED THE VENTILATION CENTRE 11 FITZWILLIAM QUAY RINGSEND DUBLIN 4 IRELAND TEL NUM 003531 6671077 FAX NUM 003531 6671055 EMAIL vent@iol.ie WEBSITE N/A PERSONNEL T KING E KING Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[79]=new Array("http://www.actionair.co.uk/int27.htm","International Sales Representation - SPAIN","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 855 SPAIN Eurotechnicas Industriales SL Techmanaval SL P Maragall 121 - ENT 2 08041 Barcelona Spain ACTUAL TIME GMT + 1HR TEL NUM 0034 933 493 712 FAX NUM 0034 933 405 258 EMAIL techmanaval@sct.icnet.es eurotecnicas@teleline.es WEBSITE N/A PERSONNEL Francisco Ros Carretero Jose Maria Sanchez Carrion SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 855 Balearic Islands OS SAFETY EQUIPMENT SL Carni Fondo s/n 07007 Palma de Mallorca Spain TEL NUM 0034 971 247 211 FAX NUM 0034 971 241 046 EMAIL palma@oscarsierra.com yessica@oscarsierra.com WEBSITE www.oscarsierra.com PERSONNEL David Miller Yessica Llabres Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2005 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[80]=new Array("http://www.actionair.co.uk/int29.htm","Actionair International Sales Representation - RUMANIA","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 830 ROMANIA ROMEC TRADE s.r.l Strada Elanului 21, sector 1 8700 Bucharest Romania ACTUAL TIME GMT + 1HR TEL NUM +40 21 5190051 FAX NUM +40 21 5190001 EMAIL ioana.popa@romectrade.com WEBSITE N/A PERSONNEL Ioana Popa Constantin Tanasa Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[81]=new Array("http://www.actionair.co.uk/int31.htm","Actionair International Sales Representation - NIGERIA","","International Sales Representation SALES AREA CODE OPERATIONAL AREA SALES REPRESENTATIVES 999 NIGERIA SEASONS GLOBAL RESOURCES LTD 130, AGGREY ROAD, PORT HARCOURT RIVERS STATE, NIGERIA (*NEW ADDRESS*) ABOUT SEASONS GLOBAL RESOURCES LIMITED Seasons Global Resources Limited were registered on July 10, 2003. We are primarily manufacturers&#8217; representative and about 60% of our clients are within the Oil &amp; Gas Sector. The remaining 40% are in other essential sectors of the economy. We are equally involved in essential Engineering and Technical Services. We represent and supply equipment in the following fields among others: ENVIRONMENTAL PRODUCTS SUPPLY: Oil Spill Detectors, Oil Spill Control/Cleanup Equipment and Chemicals, Air Pollution Control Equipment, Waste Water Treatment Chemicals, Geo-Textile Products. PIPES, PUMPS AND VALVES: Valves, Hoses and Fluid Handling Equipment, Pumps, Parts and Accessories. OCTG- Casing, Tubing, Drill Pipe, Pipe Fittings and Flanges, Products. DRILLING: Oilfield Drilling Chemicals, Oilfield Drilling Equipment, Onshore Land Drilling Rigs, Offshore Oilfield Drilling Rigs, Remote Operated Vessels. EQUIPMENT &amp; INSTRUMENTATION: Automation and Control, Flow Instrumentation, Laboratory Equipment, Marine and Subsea Equipment, Measuring Instruments, Offshore Instrumentation, Process and Control Equipment, Wire line &amp; Down hole Instruments, Alluvial Mining Equipment, Expansion Joints. REFINERY AND PETROCHEMICAL: Heat Exchangers, HVAC Equipment and Supplies, Pressure Vessels and Boilers, Petrochemical, Refinery Equipment, Separators and Filters, Compressors and Turbines. MECHANICAL &amp; ELECTRICAL SUPPLY: Engines, Motors and Parts, Generators and Transformers, Heavy Duty Equipment &amp; Machinery, Lifting Equipment and Cranes, Lightings and Electrical Products, Mechanical and Electrical Parts, Equipment. OILFIELD SAFETY SUPPLY: Fire Protection Equipment, Supplies, Industrial and Personal Gas Detectors, Equipment, and Rescue Boats. MEDICAL EQUIPMENT SUPPLY: Surgical Equipment and Hospital Furniture. MARINE EQUIPMENT SUPPLY: Swamp Buggies, Hovercrafts, Work Boats, Tug Boats, Survey Boats, Supply Boats, Dredging Equipment, Cable Handling Boats. ACTUAL TIME GMT + 1HR TEL NUM 009 234 84 234178 Mobile: +234-805-6319302 FAX NUM N/A EMAIL seasonsglobank@yahoo.co.uk aikuomola@yahoo.com WEBSITE www.seasonsglobanet.com PERSONNEL ADEOLA IKUOMOLA Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2007 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[82]=new Array("http://www.actionair.co.uk/installguides.html","Actionair Installation Guides - Smoke damper - SmokeShield Installation guide","","Home Installations Installation Guides Installation Guides New SmokeShield Installation Guide With the publication of the revised Approved Document B (ADB) on Fire safety, the guidance on the use of fire dampers in ventilation ducts to protect fire compartmentation is now much clearer. It states requirements for dampers to have ES classifications to protect escape routes and areas with sleeping risk and that generally dampers should have a minimum E classification for general areas and run out ducting. To coincide with this Actionair has produced a new SmokeShield (and HotShield) installation guide. It presents an introduction explaining what changes have occurred and a summary of the presently tested installation methods giving the E and ES classifications. This is followed by an explanation section on the background to the ADB changes and the relevant standards. This is followed by a full two page description and drawing of each method. Finally there is an appendix, which shows some of the installation methods in terms of a storyboard with photographs. Each of the sections/methods/storyboards are available as a download from the website, as is the entire document (just follow the INSTALLATIONS link). Hard copies are also available for you to keep as a reference on your shelf. It is strongly suggested that deviations from the methods given are discussed with Building Control before use, if the requirements for E and ES classifications exist. They should be able to make a judgment that the proposed method is close enough to that tested to be able to approve it. It is still possible to use dampers tested to BS476 for installations where the fan will be turned off in the case of a fire or smoke incident. All the existing methods for installations meeting the requirements for BS476 are still available on the website. Documents are available in PDF format allowing you to download. To save the file to your computer, right click on the relevant link and then click 'Save Target As':  Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[83]=new Array("http://www.actionair.co.uk/data.html","Actionair Product Data Sheets / Operating &amp; Maintenance","","Home Products Data Sheets / Operating & Maintenance Product Data Sheets Please Note: - If the data sheet you require is not provided below it will be in development for the Actionair website, so please contact Actionair on 01227 276100 for further information. All Documents are provided in PDF format. M5-3P-CMS Mode 5 Three Position Control and Monitoring Station. 113kb Mode 5-3P Control Mode 3 Position Control Mode AC/DC 24V. 165kb Mode 5-2P Actuator Motor OPEN Motor CLOSED 235kb Mode 5 and 6 PTC Compact data sheet updated January 2008 118kb (*Updated) Mode 5 and 6 PTC Regular data sheet updated January 2008 159kb (*Updated) Access/Shield Series O - Removable Insulated Access Doors. 68kb Access/Shield Series C - Removable Access Doors for Circular Ductwork. 73.5kb Access/Shield Series T - Removable Insulated Square and Rectangular. Access Doors with Tab type Fixing. 39.3kb Actionpac EM - Electro Mechanical Smoke and Fire Damper Control Systems. 70.4kb Energy/Shield 35 - Air Control and System Balancing Dampers. 66.3kb Energy/Shield 36 - Air Control and Shut-off Dampers. 67.2kb Aeropac Series PHA 230 - 230mm Deep Airside Control Fan Coil Units. For Horizontal Applications 69.8kb Hydropac Series PHW 170 - 170mm Deep Waterside Control Fan Coil Units. For Horizontal Applications. 71.8kb Hydropac Series PHW 230 - 230mm Deep Waterside Control Fan Coil Units. For Horizontal Applications. 70.7kb Trans/Shield Modes1&amp;2 - Stainless Steel Sliding Plate Fire Dampers 80.9kb Trans/Shield ACS - Fully Automated Intumescent Fire and Sliding Plate Smoke Damper 78.6kb Product Operating and Maintenance Please Note: - If the O &amp; M you require is not provided below it will be in development for the Actionair website, so please contact Actionair on 01227 276100 for further information. All Documents are provided in PDF format. A-60 Marine Fire Damper - Installation, Operating &amp; Maintenance Instructions 359kb A-60 Marine Pneumatic Fire Damper - Installation, Operating &amp; Maintenance Instructions 789kb Actionpac EMS panels - Operating &amp; Maintenance Instructions 446kb Fancoil Units - Operating &amp; Maintenance Instructions 172kb Hydropac &#8211; Horizontal waterside control; Series PHW230, Series PHW170 Aeropac &#8211; Horizontal Airside control; Series PHA230 Hydropac &#8211; Vertical waterside control ; Series PVW230 Smoke/Shield PTC, Vent/Shield PTC, Hot/Shield PTC, and Hot/Shield Vent PTC - Installation &amp; Operating Instructions 332kb Trans/Shield - Stainless Steel Sliding Plate Fire Dampers - Installation, Operating &amp; Maintenance Instructions 984kb Actionair CSS dampers - CSS Smoke ES Rated Fire Damper - Installation and maintenance instructions 614kb DRIM (Damper Release &amp; Indication Module) Installation and Operating Instructions 133kb DRIM 24 VFC (Damper Release and Indication Module with Volt Free Contacts) Installation &amp; Operating Instructions 113kb Product Document Jump Menu Catalogues All Catalogues Fire / Shield Damper Smoke/Shield PTC Damper Hot/Shield PTC PTC Control Modes and Ancillaries Energy / Shield Damper Storm Louvre Hydropac Fancoil Aeropac Fancoil A60 Marine Fire Damper Trans/Shield Modes 1&amp;2 Trans/Shield ACS Circulair Damper Actionpac LNS Controls Actionpac 60 and 120 Actionpac EMS &amp; EMB Systempac Fancoil Package Air/Shield Control &amp; Shut Off Dampers Ruskin Industrial Dampers Hot/Shield Damper Interface Enclosure DWFX-F Installation Guide Actionair DWFX Pressure Relief Flaps CSS damper Datasheets All Data Sheets M5-3P-CMS Mode 5-3P Mode 5-2P MK II Mode 5 &amp; 6 PTCTM Access/Shield Series O Access/Shield Series C Access/Shield Series T Actionpac EM Energy/Shield 35 Energy/Shield 36 Aeropac Series PHA 230 Hydropac Series PHW 170 Hydropac Series PHW 230 Trans/Shield Modes1&amp;2 Trans/Shield ACS Operating &amp; Maintenance Manuals All Operating &amp; Maintenance Manuals A-60 Marine Fire Damper A-60 Marine Pneumatic Fire Damper Fancoil Units Smoke/Shield PTC Vent/Shield PTC Hot/Shield PTC Hot/Shield Vent PTC Trans/Shield CSS Damper Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2008 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[84]=new Array("http://www.actionair.co.uk/maintenance.html","Actionair Product Recommended Spares","","Home Products Planned Maintenance Planned Maintenance 07 June 2007 PLANNED MAINTENANCE PROGRAMME Applicable to fresh air intakes, aggressive/hostile/inclement conditions and coastal areas. Suitable access to dampers, for maintenance and inspection purposes, shall be provided by others. The Maintenance department responsible for this programme should keep a Log of Date and type of Maintenance carried out. &middot; Dampers should be visually inspected and their operation checked a minimum of once every three months. &middot; Any dirt or foreign matter that may affect the correct operation of the damper should be cleared, from the blades and blade drive area. &middot; Damper inner casing and Blades should be cleaned and sprayed with a light protective lubricant (such as Rocol Z30 *), with special attention being given to the blade end bearings and the damper being worked manually through its full travel to ensure free running of the gear train. &middot; On dampers with External Linkages the blade linkage pivoting points shall be sprayed with a light oil (*) to aid movement. &middot; Dampers with concealed linkages can be sprayed with a light oil (*) to the drive areas. &middot; Spring Return Motorised Damper blades can be wound and locked open for inspection purposes without the electrical supply by means of a manual crank key that is supplied attached to the actuator. The damper will revert to its initial position when unlocked and allowed to rewind. &middot; Generally no spares are required for the Damper head units. The actuators are maintenance free and should be replaced in the event of failure. Documents are available in Microsoft Word format allowing you to add your details. To save the file to your computer, right click on the relevant link and then click 'Save Target As': PLANNED MAINTENANCE PROGRAMME   Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l");sQ1[85]=new Array("http://www.actionair.co.uk/map.html","Actionair Location Map","","Click here to print these maps Actionair - Dampers &amp; Fancoils Joseph Wilson Ind. Estate, South Street, Whitstable, Kent CT5 3DU Tel: (01227) 276100 Fax: (01227) 276100 International Code: +441227 Email: sales@actionair.co.uk Web site: www.actionair.co.uk   From the: North Dartford River Crossing (northern approach). Branch left (signposted Canterbury M2) and at roundabout take 1st exit A2. Take right hand lane to join Motorway M2 . Over M2 Medway Bridge. Junction 7 (Brenley Corner) (Junction with A2/A299) Take right-hand lane leaving Motorway (signposted Margate, Ramsgate) into Thanet Way A299. Junction with A290/A2990/B2205, Branch left A2990 (signposted Whitstable) &quot; The Long Reach&quot; public house, At roundabout take 2nd exit (signposted Chestfield, Ramsgate A299) At roundabout take the 3rd exit onto Millstrood Road, Turn right at Tescos and Actionair is located behind. From the: West M3, M25, M26, M20, A249, M2, A299 then procedure as for North. Image produced from the Ordnance Survey Get-a-map service. Image reproduced with kind permission of Ordnance Survey and Ordnance Survey of Northern Ireland. Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Products | Catalogues | Contact Copyright © 2004 actionair. All Rights Reserved Minimum system requirements | Lega l");sQ1[86]=new Array("http://www.actionair.co.uk/newredcatalogues/A60Marine.pdf","A-60_Marine Jan 08 WEB.qxd","","January 2008 A- 60 Marine Fire Dampers Includes new casing depths and thickness, Atex rated motor and visual indication options. A-60 Marine Fire Damper Designed for inclusion in Marine and Offshore Projects EW N Features Blades G 430 stainless steel and 316 stainless steel options. Casings G Lightweight cost effective design. G Rectangular and circular flanges. G Galvanised and 316 stainless steel options. G 1.2, 2, and 3mm options. G 150 and 210mm depths. G Standard and customer flange drilling options. G Visual indicator option. Actuators Electrical G 24, 120 and 230 volt options G Factory fitted ETR option. Pneumatic G 3 second reset time. G PTR release. Atex rated G Universal voltage 24 - 230V AD/DC. G Factory fitted STS option. YY denotes last two digits of year that Wheelmark is affixed to damper. A- 60 Marine Fire Dampers Introduction Actionair has, for many years, been associated in the design, development and manufacture of life safety equipment, including the supply of fire damper products to the offshore and marine industry. The Actionair A-60 Marine Fire Damper has been specifically engineered to meet stringent legislation. The A-60 Marine Fire Damper compliments the comprehensive range of automatic fire and smoke dampers and associated controls, provides the complete solution for shipboard air conditioning and ventilation systems fire safety engineering strategies. The A-60 Marine Fire Damper has been designed for inclusion in air conditioning and ventilation systems, in dry filtered air, and is tested and approved for fitting to class A-60 divisions (bulkheads and decks), when suitably insulated (refer to insulation details). With continuing research and development Actionair has extended the A-60 Product Range to include 2mm and 3mm thick casings and ATEX (Ex) rated motor options. Specification The Actionair A-60 Marine Fire Damper is constructed from galvanised steel 1.2mm thick, (2 and 3mm options available), 40mm flanged rectangular or circular casing, (All 316 stainless steel option available). 75mm interlocking 430 grade stainless steel aerodynamic blades, steel blade end bearings and 300 grade stainless steel peripheral gasketting. (316 grade stainless steel blade and blade end bearing available). The totally enclosed precise movement opposed blade drive is positioned out of the airstream for protection against damage, and is hard wearing and free running. Electrical The Actionair direct-coupled spring return fail-safe electrical control modes are fitted with halogen free low smoke and fume electrical cable. They have a 60 second reset time and a 20 second release time. Each actuator has a 72 °C rated electrical thermal release (ETR). The ETR incorporates a safety electrical interlock that only permits actuator operation when correctly fitted. A green 'Healthy' indication lamp is built into the ETR housing to give a simple and clear visual check that the actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. A manual test switch allowing periodic operation of the damper for testing purposes simulates actual fail-safe release under smoke/fire conditions. End switches are provided with each mode for reset and release monitoring. Electrical ATEX (Ex) rated. The Actionair direct-coupled spring return fail-safe ATEX (Ex) electrical control modes are fitted with 1 metre of cable for connection inside hazardous areas. They have the benefit of a Universal electrical supply using any Voltage between 24230 V AC/DC, which is self adaptable. They have Variable (3-15-30 - 60 -120 sec/90°C) Reset and (3-10 sec/90°C) Release times, which are selectable on site. Each actuator has a Integral safety temperature sensor (STS) rated at 72°C. The STS incorporates a triple fail-safe thermal fuse arrangement, 2 induct and one outside, to ensure the fail-safe actuator operates in all conditions. A manual test switch allowing periodic operation of the damper for testing purposes simulates actual fail-safe release under smoke/fire conditions. End switches are provided with each mode for reset and release monitoring. An Integral heater allows the unit to be operated within ambient temperatures down to 40°C. Pneumatic The Actionair direct coupled spring return fail-safe pneumatic control mode requires an air pressure of between 5 to 8 bar (72 to 116 psi) to operate. They have 3 second reset and release time. Each actuator has a pneumatic thermal release (PTR). The PTR assembly is supplied with 500mm nylon tubing that connects to the quick fit couplings of the PTR and actuator. Incorporated is a fail-safe 74°C fusible link. When this operates, air exhausts from the actuator, permitting the spring return actuator to go to the failsafe position, thus closing the damper. Switch box and solenoid accessories are available for monitoring and control. Tests and Approval list *Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3, for Class A60 bulkheads and decks. *Marine Equipment Directive 96 /98 /EC. *USCG Approved (product category 164.139). *Germanischer Lloyds Approved to IMO Res. A.754. (18) and IMO Res. MSC61(67), Annex 1 Part 3. *American Bureau of Shipping Approved to: 2005 Steel Vessel Rules 1-1-4/7.7. Please note maximum size restrictions see page 4. Corrosion tested. Vibration tested. All certificates are available via the Actionair website. www.actionair.co.uk 2 www.actionair.co.uk A- 60 Marine Fire Dampers Range and Application The A-60 dampers can be used where the maximum system pressure is up to 1500 Pa and duct velocities to 15m/s. A-60 Marine Fire Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication, to the blade and drive area, in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions please refer to Actionair Technical Sales Office. The A-60 Marine Fire Damper is suitable for both vertical and horizontal applications, with airflow in either direction. The dampers are normally open, and failsafe to the closed position. Electrical Fail-safe is by means of a unique and patented Electrical Thermal Release (ETR) which operates at 72 °C, or if power supply is interrupted. The ETR incorporates a safety feature, that ensures the fail-safe status of the damper if the ETR is not fitted on to the ductwork. Additionally a green LED lamp is built into the ETR housing. This gives the user a simple and clear visual check that the Actuator is receiving power, the ETR is correctly fitted, and the thermal fuse is intact. A manual test switch allows periodic operation of the damper for testing purposes, simulating actual fail-safe release under fire conditions. The associated electrical control Modes are available in 24 volt, 120 volt or 230 volt versions. Electrical Thermal Release (ETR) Electrical ATEX (Ex) rated. Fail-safe is by means of a Safety Temperature Sensor (STS) which operates at 72 °C, or if power supply is interrupted. A manual test switch allows periodic operation of the damper for testing purposes, simulating actual fail-safe release under fire conditions. The associated electrical control Modes are available in one Universal version with 24 ­ 230 volt AC/DC supply. Safety Temperature Sensor (STS) Pneumatic The special purpose design Pneumatic Thermal Release (PTR) assembly is supplied with 500mm nylon tubing that connects to the quick fit couplings of the PTR and actuator. Incorporated is a failsafe 74°C fusible link. When this activates, air exhausts from the actuator, enabling the PTR to spring return to the fail-safe position, thus closing the damper. Pneumatic Thermal Release (PTR) www.actionair.co.uk 3 A- 60 Marine Fire Dampers Insulation Details Bulkhead (Vertical) STRUCTURAL STEEL CORE 75 Deck (Horizontal) COAMING See page 7 300 See Below ** See Below 40 ** 50 DAMPER COAMING See Below CONNECTION OF DAMPER TO COAMING ** 225 See page 7 40 25 40 40 CONNECTION OF DAMPER TO COAMING MINERAL FIBRE INSULATION (110Kg PER CUBIC METRE) 50 25 DAMPER * Table of Minimum Total Coaming Insulation Length (Applies to all approval bodies) Application Vertical bulkhead up to 750 x 750 (0.5625msq) Vertical bulkhead above 0.5625 msq Horizontal deck up to 750 x 750 (0.5625msq) Insulation Thickness 75mm 40mm 75mm Minimum Total Insulation Length 725mm refer to graph below 725mm refer to graph below 725mm Horizontal deck above 0.5625 msq Horizontal deck (all sizes) The same area/insulation criteria applies for multiple arrangements Graph Showing Minimum Insulation length for Damper above 750mm x 750mm Base Damper (Applies to all approval bodies with the exception of ABS) 1100 1050 Coaming Insulation Example For a damper size of 910mm x 925mm. Area = 0.85 msq Vertical Installation Insulation Thickness = 75mm (line 2 of table) Insulation Length = 975mm (refer to graph) Horizontal Installation Insulation Thickness = 40mm Insulation Length = 975mm Insulation Thickness = 75mm Insulation Length = 725mm 0.5 0.55 0.6 0.65 0.7 0.8 0.85 0.9 0.95 1 Total Insulation length (mm) 1000 950 900 850 800 750 700 (line 4 of table) (refer to graph) (line 5 of table) (line 5 of table) Area (msq) Note: for circular, use square base damper area. 4 www.actionair.co.uk A- 60 Marine Fire Dampers Testing Casing Features The standard 1.2mm galvanised steel flanged type casing,(optional 2 and 3mm thick), having a single penetration for the drive control, complies to Class A & B of Eurovent 2/2 and Test Procedures for Classes A, B ,& C of the HVCA Ductwork Specification DW144. Pre-punched bolt holes are provided as standard (refer to page 7 and 8). 1.2mm Casing In addition Stainless Steel peripheral gasketing is included, which allows for expansion under full fire conditions. The 1.2mm casing has obvious benefits, for example being lighter in weight, allowing easier installation. Casings manufactured in Type 1.4401 (316 grade) Austenitic Stainless Steel are available as an optional extra. The Actionair A-60 Marine Fire Damper has undergone extensive fire testing in single and multiple arrangements. The dampers were incorporated in steel bulkheads and decks and tested to the Marine Fire Resistance Test in accordance with IMO resolution A754. (18) for a duration of 60 minutes. Changes to the originally supplied product may invalidate the certification and/or warranty. Certification EC Type Examination (Module B) Certificate. EC (Module D) Certificate of Conformity. Certificate of Fire Approval. Germanischer Lloyds Fire Certification. ABS Approved. ISO 9001; 2000 Certification. *Corrosion Tested to BSEN 60068-2-52, severity 2 conditions. *Vibration Tested to BS EN 60068-2-6 (5Hz to 350Hz @ 2g). Copies of All Certification and Test Reports are available from our website. Factory fitted Actuator Options (Electrical only) Changes/ modifications to the original supplied product may invalidate certification and/or warranty. 2 and 3mm Casing Casing Mounted ETR A-60 Electrical with fitted ETR A-60 Atex with fitted STS www.actionair.co.uk 5 A- 60 Marine Fire Dampers Electrical Control Modes Standard Control Modes The IP54 rated Control Modes, are located outside of the ductwork for ease of access and installation.Control Modes fitted to dampers up to 400mm high, can be fitted in any one of three orientations i.e. vertically down,horizontally or vertically up. Positions 1, 2, or 3). Two sizes (Compact and Universal) of Control Mode are utilised. This flexibility ensures that the smaller damper sizes and Control Mode require the minimal amount of room. For damper sizes above 400mm high the control mode is fitted vertically. Correctly sized Control Modes are designed to fit only to the relevant sized damper. The control modes are direct coupled to the damper utilising a unique user friendly positive connection system. This allows the dampers and actuators to be supplied separately, offering shipping and storage benefits. DAMPER DRIVE SHAFT MOUNTING PLATE ADAPTOR PLATE 150 or 210 85 Position 3 Position 2 LABEL SIDE Position 1 30 100 Fig. 1 Three Position Compact 150 or 210 123 Position 3 Position 2 248 Position 1 100 LABEL SIDE Control Mode Standard Parameters 1000 Fig.2 Three Position Universal 150 or 210 DAMPER HEIGHT 400 Single Position Universal Fig. 3 LABEL SIDE Three Position Compact Fig. 1 Three Position Universal Fig. 2 100 100 100 400 DAMPER WIDTH 1000 Fig. 3 Single Position Universal Blade Features The damper blades are aerodynamic double skin, Type 1.4016 (430 grade) Ferritic Stainless Steel, which are 75mm wide and when closed interlock to form a positive fire resisting shield. Incorporated in the blade are steel blade end bearings. Optional blades in Type 1.4401 (316 grade) Austenitic Stainless can be provided. Incorporated in the blade are 316 Stainless Steel blade end bearings. 12.7 1 Position Actuator Optional Silicon blade seals can be provided for low leakage requirement at ambient temperature. 41.5 75 6 www.actionair.co.uk 248 155 A- 60 Marine Fire Dampers Electrical Application and Wiring Standard Application and Wiring Control Mode 5 24V A.C. or D.C. Control Mode 6 230V A.C. 50/60Hz Control Mode 120 120V A.C. 50/60Hz A.C./D.C.24V 50 / 60 Hz Mode 5 24V System BLACK 1 2 ­ + M WHITE SUPPLY 24V A.C. or D.C. TYPICALLY 10W (MOTORING) 2W (RESET) Power On Power Off ETR Operates - Damper motors open. Damper springs closed. Damper springs closed. 1 2 CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED 12W (Maximum Motoring). 4W (Maximum Reset). End Switches Rated at 250V 1.5 Amp (Maximum). To isolate from main power supply, the system must incorporate a device, which disconnects the phase conductors, with at least 3mm contact gap. TF 72 °C 12.5 V A 10 / 2 W Imax 8.3A @ 5ms 3 A.C. 250V 6(3)A 4 5 6 CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET 2 x 1 metre of halogen free, low smoke and fume electric cables are included with each control mode. The ETR is also prewired with 0.5 metre halogen free low smoke and fume cable. ­ 30...+50 °C CONTINUOUS ELECTRICAL THERMAL RELEASE (MUST BE FITTED FOR DAMPER OPERATION). (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Mode 6 230V System (Also 120V Typical) BLUE N L1 M A.C. 230V 50 / 60 Hz BROWN SUPPLY 230V A.C.50/60 Hz TYPICALLY12W (MOTORING) 4W (RESET 1 2 3 4 14 V A 12 / 4 W CONTACT MADE BETWEEN 1 AND 2 WHEN DAMPER FULLY RELEASED A.C. 250V 6(3)A 5 6 CONTACT MADE BETWEEN 4 AND 6 WHEN DAMPER FULLY RESET ­ 30...+50 °C CONTINUOUS TF 72 °C ELECTRICAL THERMAL RELEASE (MUST BE FITTED FOR DAMPER OPERATION). (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE www.actionair.co.uk 7 A- 60 Marine Fire Dampers ATEX (Ex) Rated Control Modes The ATEX rated Control Modes, are located outside of the ductwork for ease of access and installation. Control Modes can be fitted in any one of three orientations, i.e. vertically down, horizontally or vertically up. Positions 1, 2, or 3. The control modes are direct coupled to the damper utilising a unique user friendly positive connection system. This allows the dampers and actuators to be supplied separately, offering shipping and storage benefits. 8 www.actionair.co.uk A-60 Marine Fire Dampers ATEX (Ex) Rated Actuator, Application and Wiring Atex (Ex) Rated Electrical Control Modes Universal supply unit from 24 to 230V-AC/DC. Power On - Damper motors open. Power Off - Damper springs closed. STS Operates - Damper springs closed. 20W (Maximum Blocking), 16W (Heater). End Switches Rated at 250V 1.5 Amp (Maximum). To isolate from main power supply, the system must incorporate a device, which disconnects the phase conductors, with at least 3mm contact gap. A metre of halogen free, low smoke and fume electric cable is included with each control mode. The STS is also prewired with a metre of halogen free low smoke and fume cable. PE On-off 1-wire-spring return + EEx-i circuit Integrated aux, switches max 24V/3A, 230V/O, 5A switching at 5° and 85° Supply at aux. switches must be the same like supply of the actuator on the same fuse &lt; 5° &lt; 85° EEx-i circuit for passive + potential free push button on site and safety temperature sensor (Type STS accessories. 24...230 VAC/DC ­ ~ + Attention ~ If you use this typeof wiring the heaterdoes not work in case of open contact STS °C Push button A B 1 2 3 4 5 6 7 8 9 10 11 1 2 PA Heater Standard wiring = spring return in ~10 sec Additional wiring terminal 5 = spring return in ~3 sec Power input depending on supply voltage Power supply design The design of the on-site supply, depends on the selected motor running time and selected supply voltage. Accompanying values are&quot;about values&quot;, since there can be construction unit dispersions within electronics. The power consumption in the blocking position is run time independently with max 20W. The power consumption for the heater is approximately 16W. The heading is running only if the motor is in idle position. The initial starting supply voltage required by the actuators power supply unit is around 2.0A for about 1 sec. (Please consider this while concepting the cross section of the supply line.) Dimensioning of the line cross section with24....48 Volt AC/DC supply voltages Dimensioning / Design of the supply line On long distances between voltage and drive, voltage drops occur due to line resistances. As a consequence with 24V AC/DC the actuator receives a too low tension and does not start. In order to prevent this, the cross section of the inlet line is to be designed/dimensioned accordingly. The accompanying formula allows the calculation of the necessary line cross section, perhaps provides the maximally conduit length utilising the existing line cross section. Alternatively the secondary voltage can be increased by selecting a transformer. For calculation purposes, following characteristics are essential: UV = supply voltage in [V] A = line cross section in [mm2] L = conduit length in [m] Factor 0.0714 = drive-specific factor [Vmm2/m] 9 based on the electrical conductivity of electrolytic copper with a coefficient of 56/Wmm2) Rated current in acc. with motor running time Voltage 230V 120V 48V 24V Current Irated Irated Irated Irated 3/7,5s 0.5A 0.75A 2.0A 4.7A 15s 0.3A 0.4A 0.5A 1.45A 30s 0.15A 0.3A 0.3A 0.52A 60s 0.10A 0.25A 0.2A 0.4A 120s 0.10A 0.25A 0.2A 0.4A Panel Uv [m] 28 27 26 25 24 23 22 21 20 50 100 150 200 250 300 350 400 L [m] 4mm2 1mm2 1.5mm2 2.5mm2 Voltage &quot;Uv&quot; [V] Line cross section &quot;A&quot; [mm2] Terminal box Actuator Lenght &quot;L&quot; [m] Formula for maximum cable length &quot;L&quot; at cable cross section &quot;A&quot; L = A · (Uv-18V) : 0.0714 Example: A = 1.5mm2, Uv = 24V Length of cable L = 126m Formula of needed cable cable cross section &quot;A&quot; at a cable length of &quot;L&quot; A = 0.0714 · L : (Uv-18V) Example: L = 250m, Uv = 30V Cross section of A = 1.5mm2 Example: 24V power supply with diameter 1.5mm2 = 126m www.actionair.co.uk 9 A- 60 Marine Fire Dampers Pneumatic Control Mode Pneumatic Thermal Release (PTR) 4mm diameter tubing 500mm length connection to actuator All dimension are in millimetres 2 off quick release connectors, supplied Input: 6mm diameter, quick release connector, pressure range 5 - 8 Bar Pneumatic Operation Air On - Damper opens. Air Off - Spring closure. Release time 2 ­ 4 secs. Reset time 2 ­ 4 secs. Air inlet 6mm dia. quick fit coupling. 74 °C Pneumatic Thermal Release (PTR). Air consumption to reset @ 5.5 bar = 535cc. External mechanical position indicator. Test operation by removing fusible link element. 255 160 55 59 222 Dimensional Data Pneumatic Spring Return Actuator *SWITCHBOX / STATUS BEACON CABLE ENTRY POINTS 115 95 102 *SOLENOID *Optional Extras Pneumatic Actuator 8 25 Plan view cross section showing Control Mode dimensions 78 40 MINIMUM REMOVAL DIMENSION 275mm 10 www.actionair.co.uk A- 60 Marine Fire Dampers Dimensional Data Square and Rectangular (A-60 RECT) 150 or 210 MIN 75 MAX 150 150 150 MIN 75 MAX 150 40 MIN 75 MAX 150 All dimension are in millimetres Circular (A-60 CIRC) 230 or 290 40 SEE TABLE BELOW FOR NUMBER OF HOLES, TO BE EQUALLY SPACED ON PCD ALIGNMENT OF HOLES TAKEN FROM CENTRE LINE OF SQUARE SECTION PLATE 40 50 40 MIN 75 MAX 150 20 DAMPER WIDTH* 100 - 1000 20 40 DAMPER DIA 100 -1000 DAMPER HEIGHT 100 -1000 150 150 PCD = NOM . DIA. + 40mm HOLE DIM. SEE TABLE BELOW Electrical Actuator 56 8 25 Atex Electrical Circular Damper Fixing Hole Details Damper Dia. No. of Holes 100 - 250 251 - 500 100 Hole Dia. 7.0 10.0 12.0 12.0 4 off 8 off 12 off 16 off 78 14 501 - 750 751 - 1000 40 MINIMUM REMOVAL DIMENSION 90mm MINIMUM REMOVAL DIMENSION 110mm 40 Multiple Assemblies DAMPER WIDTH 1580 Maximum Multiple width assemblies (2 x 1) have been tested and approved to a size of 1580mm wide x 750mm high. 50 TOP DAMPER HEIGHT 750 Maximum MOTOR MOTOR 12mm DIA. HOLES IN EACH CORNER AND EQUALLY SPACED AT 150mm MAX. CENTRES BOTH SIDES OF FLANGES ON EACH INDIVIDUAL DAMPER 20 40 FLANGE ALL AROUND 75mm WIDE JOINING STRIP. (BOTH SIDES) RIVETTED WITH 3.2mm STEEL RIVETS AT 100mm CENTRES, ON SITE BY OTHERS 150 or 210 20 www.actionair.co.uk 11 A- 60 Marine Fire Dampers Weights 1.2mm Galvanised Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 3.0 3.9 4.1 4.7 5.3 5.6 6.2 7.1 7.4 8.0 8.6 8.9 9.5 150 3.4 4.3 4.6 5.2 5.8 6.1 6.7 7.7 8.0 8.6 9.3 9.5 10.2 200 3.8 4.8 5.0 5.7 6.4 6.6 7.3 8.3 8.6 9.2 9.9 250 4.2 5.2 5.5 6.2 6.9 7.2 7.8 8.9 9.2 9.9 10.6 300 4.6 5.7 5.9 6.7 7.4 7.7 8.4 9.5 9.7 350 5.1 6.1 6.4 7.2 7.9 8.2 8.9 400 5.5 6.6 6.9 7.6 8.4 8.7 9.5 450 5.9 7.0 7.3 8.1 8.9 9.2 500 6.3 7.5 7.8 8.6 9.5 9.7 550 6.7 7.9 8.2 9.1 600 7.1 8.4 8.7 9.6 650 7.6 8.8 9.1 10.1 11.0 11.3 12.2 13.6 13.8 14.8 15.8 16.1 17.0 18.0 18.3 19.2 20.2 20.5 21.5 700 8.0 9.3 9.6 10.5 11.5 11.8 12.8 14.2 14.4 15.4 16.4 16.7 17.7 18.7 19.0 20.0 21.0 21.3 22.3 750 8.4 9.7 10.0 11.0 12.1 12.3 13.3 14.7 15.0 16.1 17.1 17.4 18.4 19.4 19.7 20.7 21.8 22.1 23.1 800 8.8 10.2 10.5 11.5 12.6 12.9 13.9 15.3 15.6 16.7 17.7 18.0 19.1 20.2 20.4 21.5 22.6 22.8 23.9 3.00kg 3.50kg 850 9.2 900 9.7 950 10.1 1000 10.5 12.0 12.3 13.5 14.7 14.9 16.1 17.7 18.0 19.2 20.4 20.6 21.8 23.0 23.3 24.5 25.7 26.0 27.2 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 4.6 6.8 8.1 9.8 12.0 13.4 15.4 18.2 19.8 22.0 24.6 26.4 28.9 31.7 33.6 36.3 39.4 41.5 44.5 10.6 11.1 11.5 10.9 11.4 11.8 12.0 12.5 13.0 13.1 13.6 14.1 13.4 13.9 14.4 14.5 15.0 15.6 15.9 16.5 17.1 16.2 16.8 17.4 17.3 17.9 18.5 18.4 19.0 19.7 18.7 19.3 20.0 19.8 20.5 21.2 20.9 21.6 22.3 21.2 21.9 22.6 22.3 23.0 23.8 23.4 24.1 24.9 23.6 24.4 25.2 24.7 25.6 26.4 10.0 10.5 10.3 10.8 11.1 11.7 12.4 13.0 12.7 13.3 13.6 14.2 14.5 15.1 14.8 15.4 15.7 16.3 16.6 17.3 16.8 17.5 17.7 18.5 18.6 19.4 18.9 19.7 19.8 20.6 10.0 10.6 11.2 11.8 11.5 12.1 12.3 13.0 13.2 13.8 13.4 14.1 14.3 15.0 15.1 15.8 15.4 16.1 16.2 17.0 17.1 17.8 17.3 18.1 18.2 19.0 10.1 10.6 10.3 10.9 10.5 11.1 11.7 11.2 11.9 12.5 11.5 12.1 12.8 12.2 12.9 13.6 13.0 13.7 14.4 13.2 13.9 14.7 14.0 14.7 15.5 14.7 15.5 16.3 15.0 15.8 16.5 15.7 16.5 17.4 1.85kg 3.00kg 10.2 10.8 10.9 11.5 11.5 12.2 11.8 12.5 12.5 13.2 13.1 13.9 13.4 14.2 14.1 14.9 10.1 10.8 10.3 11.1 11.0 11.7 11.5 12.3 11.8 12.6 1000 12.4 13.2 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate Weights 2mm Galvanised Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 4.1 5.2 5.6 6.3 7.1 7.5 8.2 9.3 9.8 150 4.7 5.8 6.2 7.0 7.8 8.2 8.9 10.1 10.5 200 5.3 6.4 6.8 7.6 8.4 8.9 9.7 250 5.9 7.0 7.4 8.3 9.1 9.6 10.4 300 6.4 7.6 8.1 8.9 9.8 350 7.0 8.3 8.7 9.6 400 7.6 8.9 9.3 10.2 450 8.2 9.5 9.9 500 8.8 10.1 10.5 550 9.4 600 10.0 650 10.6 12.0 12.4 13.5 14.6 15.0 16.1 17.6 18.1 19.2 20.3 20.7 21.8 23.0 23.4 24.5 25.6 26.1 27.2 700 11.1 12.6 13.0 14.2 15.3 15.7 16.9 18.4 18.8 20.0 21.1 21.5 22.7 23.9 24.3 25.4 26.6 27.0 28.2 750 11.7 13.2 13.6 14.8 16.0 16.4 17.6 19.1 19.6 20.8 21.9 22.4 23.6 24.7 25.2 26.4 27.5 28.0 29.2 800 12.3 13.8 14.3 15.5 16.7 17.1 18.3 19.9 20.3 21.5 22.8 23.2 24.4 25.6 26.1 27.3 28.5 28.9 30.2 3.00kg 3.50kg 850 900 950 1000 14.7 16.3 16.7 18.1 19.4 19.9 21.2 22.9 23.3 24.7 26.0 26.5 27.8 29.2 29.6 31.0 32.3 32.8 34.1 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 12.9 13.5 14.1 14.5 15.1 15.7 14.9 15.5 16.1 16.1 16.8 17.4 17.4 18.0 18.7 17.8 18.5 19.2 19.0 19.7 20.5 20.6 21.4 22.2 21.1 21.8 22.6 22.3 23.1 23.9 23.6 24.4 25.2 24.0 24.8 25.6 25.3 26.1 27.0 26.5 27.4 28.3 26.9 27.8 28.7 28.2 29.1 30.0 29.5 30.4 31.4 29.9 30.8 31.8 31.1 32.1 33.1 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 6.1 8.8 10.7 12.9 15.6 17.6 20.1 23.4 25.6 28.4 31.6 33.9 37.0 40.5 43.0 46.3 50.1 52.7 56.4 10.7 11.3 11.2 11.8 12.2 12.8 13.2 13.9 13.7 14.4 14.7 15.4 16.1 16.9 16.5 17.3 17.6 18.4 18.7 19.5 19.1 19.9 20.1 21.0 21.2 22.1 21.6 22.5 22.7 23.6 23.7 24.7 24.1 25.1 25.2 26.2 10.9 11.5 11.9 12.6 12.3 13.0 13.3 14.0 14.6 15.4 15.0 15.8 16.0 16.8 17.0 17.8 17.4 18.3 18.4 19.3 19.4 20.3 19.8 20.7 20.8 21.7 21.8 22.8 22.2 23.2 23.2 24.2 10.5 11.2 10.2 10.9 11.6 11.1 11.8 12.5 12.3 13.1 13.9 12.8 13.5 14.3 13.7 14.5 15.2 14.5 15.4 16.2 15.0 15.8 16.6 15.9 16.7 17.6 16.7 17.6 18.5 17.2 18.1 18.9 18.1 19.0 19.9 18.9 19.9 20.9 19.4 20.3 21.3 20.3 21.2 22.2 1.85kg 3.00kg 10.8 11.6 11.3 12.0 12.1 12.9 12.9 13.7 13.3 14.2 14.2 15.0 15.0 15.9 15.4 16.3 16.2 17.1 17.0 18.0 17.5 18.4 18.3 19.3 10.5 11.3 11.3 12.1 11.7 12.5 12.4 13.3 13.2 14.1 13.6 14.5 14.4 15.3 15.1 16.1 15.5 16.5 1000 16.3 17.3 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate 12 www.actionair.co.uk A- 60 Marine Fire Dampers Weights 3mm Galvanised Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 5.5 6.8 7.4 8.3 9.3 9.9 150 6.3 7.6 8.2 9.2 10.2 10.8 200 7.1 8.4 9.1 250 7.9 9.3 9.9 300 8.7 350 9.5 400 10.3 450 500 550 600 650 14.3 15.9 16.5 17.8 19.2 19.8 21.1 22.7 23.4 24.7 26.0 26.6 27.9 29.2 29.8 31.2 32.5 33.1 34.4 700 15.1 16.8 17.4 18.7 20.1 20.7 22.0 23.7 24.3 25.7 27.0 27.6 29.0 30.3 31.0 32.3 33.6 34.3 35.6 750 15.9 17.6 18.2 19.6 20.9 21.6 22.9 24.7 25.3 26.7 28.0 28.7 30.1 31.4 32.0 33.4 34.8 35.4 36.8 800 16.7 18.4 19.0 20.4 21.8 22.5 23.9 25.6 26.3 27.7 29.1 29.7 31.1 32.5 33.1 34.6 36.0 36.6 38.0 3.00kg 3.50kg 850 900 950 1000 19.9 21.8 22.4 23.9 25.4 26.1 27.6 29.5 30.1 31.7 33.2 33.8 35.4 36.9 37.6 39.1 40.7 41.3 42.8 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 11.1 11.9 12.6 13.4 13.2 14.0 14.4 15.2 15.6 16.5 16.2 17.1 17.3 18.3 18.9 19.8 19.5 20.5 20.7 21.7 21.8 22.9 22.5 23.5 23.6 24.7 24.8 25.9 25.4 26.5 26.6 27.8 27.8 29.0 28.4 29.6 29.6 30.8 12.7 13.5 14.3 15.1 14.9 15.7 16.1 17.0 17.4 18.2 18.0 18.9 19.2 20.1 20.8 21.8 21.4 22.4 22.7 23.7 23.9 24.9 24.5 25.6 25.8 26.8 27.0 28.1 27.6 28.7 28.9 30.0 30.1 31.3 30.8 31.9 32.0 33.2 17.5 18.3 19.1 19.3 20.1 20.9 19.9 20.7 21.5 21.3 22.2 23.0 22.8 23.6 24.5 23.4 24.3 25.2 24.8 25.7 26.7 26.6 27.6 28.5 27.2 28.2 29.2 28.7 29.7 30.7 30.1 31.1 32.2 30.7 31.8 32.8 32.2 33.3 34.3 33.6 34.7 35.8 34.3 35.3 36.5 35.7 36.8 38.0 37.2 38.3 39.5 37.8 38.9 40.1 39.2 40.4 41.6 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 8.4 11.9 14.5 17.6 21.1 23.9 27.3 31.5 34.5 38.2 42.4 45.6 49.7 54.1 57.6 61.9 66.7 70.4 75.1 10.1 10.9 11.8 10.7 11.6 12.4 11.8 12.7 13.5 12.9 13.8 14.7 13.5 14.4 15.3 14.5 15.5 16.4 16.0 16.9 17.9 16.6 17.6 18.5 17.7 18.7 19.7 18.7 19.8 20.8 19.4 20.4 21.4 20.4 21.5 22.6 21.5 22.6 23.7 22.1 23.2 24.3 23.2 24.4 25.5 24.3 25.5 26.6 24.9 26.1 27.3 26.0 27.2 28.4 1.85kg 3.00kg 10.1 10.9 11.1 12.0 11.7 12.6 12.7 13.6 14.0 15.0 14.7 15.6 15.7 16.7 16.7 17.7 17.3 18.3 18.3 19.4 19.3 20.4 19.9 21.0 21.0 22.1 22.0 23.1 22.6 23.8 23.6 24.8 10.8 11.7 12.1 13.1 12.7 13.7 13.7 14.7 14.6 15.6 15.2 16.3 16.2 17.2 17.1 18.2 17.7 18.8 18.7 19.8 19.6 20.8 20.2 21.4 1000 21.2 22.4 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate Weights 1.2mm 316 Stainless Steel Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 3.0 3.9 4.2 4.8 5.4 5.7 6.2 7.2 7.5 8.1 8.7 9.0 9.6 150 3.4 4.4 4.6 5.3 5.9 6.2 6.8 7.8 8.1 8.7 9.4 9.7 10.3 200 3.9 4.8 5.1 5.8 6.4 6.7 7.4 8.4 8.7 9.4 250 4.3 5.3 5.6 6.3 7.0 7.3 8.0 9.0 9.3 10.0 300 4.7 5.8 6.0 6.8 7.5 7.8 8.5 9.6 9.9 350 5.1 6.2 6.5 7.3 8.0 8.3 9.1 400 5.6 6.7 7.0 7.8 8.6 8.9 9.7 450 6.0 7.1 7.4 8.3 9.1 9.4 500 6.4 7.6 7.9 8.8 9.6 9.9 550 6.8 8.1 8.3 9.3 600 7.3 8.5 8.8 9.7 650 7.7 9.0 9.3 10.2 11.2 11.5 12.5 13.9 14.1 15.1 16.1 16.4 17.4 18.4 18.7 19.7 20.7 21.0 22.0 700 8.1 9.5 9.7 10.7 11.8 12.1 13.1 14.5 14.7 15.8 16.8 17.1 18.1 19.2 19.4 20.5 21.5 21.8 22.8 750 8.5 9.9 10.2 11.2 12.3 12.6 13.6 15.1 15.3 16.4 17.5 17.8 18.8 19.9 20.2 21.2 22.3 22.6 23.7 800 9.0 10.4 10.6 11.7 12.8 13.1 14.2 15.7 15.9 17.1 18.2 18.4 19.5 20.6 20.9 22.0 23.1 23.4 24.5 3.00kg 3.50kg 850 9.4 900 9.8 950 10.2 1000 10.7 12.2 12.5 13.7 15.0 15.2 16.5 18.1 18.4 19.6 20.9 21.1 22.4 23.6 23.9 25.2 26.4 26.7 27.9 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 4.7 6.9 8.2 10.0 12.2 13.7 15.7 18.5 20.1 22,4 25.1 26.9 29.5 32.4 34.3 37.1 40.4 42.4 45.5 10.8 11.3 11.8 11.1 11.6 12.0 12.2 12.7 13.2 13.4 13.9 14.4 13.6 14.2 14.7 14.8 15.3 15.9 16.3 16.9 17.5 16.5 17.1 17.8 17.7 18.3 19.0 18.8 19.5 20.2 19.1 19.8 20.5 20.3 21.0 21.7 21.4 22.1 22.9 21.7 22.4 23.2 22.8 23.6 24.4 24.0 24.8 25.6 24.2 25.0 25.9 25.4 26.2 27.1 10.2 10.7 10.5 11.0 11.4 11.9 12.7 13.2 12.9 13.5 13.9 14.5 14.8 15.5 15.1 15.7 16.0 16.7 16.9 17.7 17.2 17.9 18.1 18.9 19.0 19.9 19.3 20.1 20.3 21.1 10.2 10.8 11.4 12.0 11.7 12.3 12.6 13.2 13.4 14.1 13.7 14.4 14.6 15.3 15.4 16.2 15.7 16.4 16.6 17.3 17.4 18.2 17.7 18.5 18.5 19.4 10.2 10.8 10.5 11.1 10.7 11.3 11.9 11.4 12.1 12.8 11.7 12.4 13.0 12.4 13.1 13.9 13.2 13.9 14.7 13.5 14.2 15.0 14.2 15.0 15.8 15.0 15.8 16.6 15.2 16.1 16.9 16.0 16.8 17.7 1.85kg 3.00kg 10.1 10.7 10.3 11.0 11.0 11.7 11.7 12.4 12.0 12.7 12.6 13.4 13.3 14.1 13.6 14.4 14.3 15.1 10.2 10.9 10.5 11.2 11.1 11.9 11.7 12.5 12.0 12.8 1000 12.6 13.4 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate www.actionair.co.uk 13 A- 60 Marine Fire Dampers Weights 2mm 316 Stainless Steel Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 4.2 5.2 5.6 6.4 7.2 7.6 8.3 9.4 9.9 150 4.8 5.8 6.3 7.1 7.8 8.3 9.1 10.2 10.6 200 5.3 6.5 6.9 7.7 8.6 9.0 9.8 250 5.9 7.1 7.5 8.4 9.3 9.7 10.5 300 6.5 7.7 8.2 9.1 350 7.1 8.4 8.8 9.7 400 7.7 9.0 9.4 10.4 450 8.3 9.6 500 8.9 10.3 550 9.5 600 10.1 650 10.7 12.2 12.6 13.7 14.9 15.3 16.4 18.0 18.4 19.5 20.7 21.1 22.3 23.4 23.9 25.0 26.2 26.6 27.8 700 11.3 12.8 13.2 14.4 15.6 16.0 17.2 18.7 19.2 20.4 21.5 22.0 23.2 24.4 24.8 26.0 27.2 27.6 28.8 750 11.9 13.4 13.9 15.1 16.3 16.7 17.9 19.5 19.9 21.2 22.4 22.8 24.0 25.3 25.7 26.9 28.1 28.6 29.8 800 12.5 14.1 14.5 15.7 17.0 17.4 18.7 20.3 20.7 22.0 23.2 23.7 24.9 26.2 26.6 27.9 29.1 29.6 30.8 3.00kg 3.50kg 850 900 950 1000 14.9 16.6 17.0 18.4 19.8 20.2 21.6 23.4 23.8 25.2 26.6 27.0 28.5 29.9 30.3 31.7 33.1 33.5 34.9 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 13.1 13.7 14.3 14.7 15.3 16.0 15.1 15.7 16.4 16.4 17.1 17.7 17.7 18.4 19.1 18.1 18.8 19.5 19.4 20.1 20.9 21.1 21.8 22.6 21.5 22.3 23.0 22.8 23.6 24.4 24.1 24.9 25.8 24.5 25.4 26.2 25.8 26.7 27.6 27.1 28.0 28.9 27.5 28.4 29.4 28.8 29.8 30.7 30.1 31.1 32.1 30.6 31.5 32.5 31.9 32.9 33.9 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 6.2 9.0 10.8 13.1 15.9 17.9 20.5 23.8 26.0 28.9 32.2 34.6 37.8 41.3 43.8 47.3 51.1 53.9 57.6 10.9 11.5 11.3 12.0 12.4 13.1 13.5 14.2 13.9 14.6 15.0 15.7 16.4 17.2 16.8 17.6 17.9 18.7 19.0 19.8 19.4 20.3 20.5 21.4 21.6 22.5 22.0 22.9 23.1 24.1 24.2 25.2 24.6 25.6 25.7 26.7 10.1 10.7 11.1 11.7 12.1 12.8 12.5 13.2 13.5 14.2 14.9 15.6 15.3 16.1 16.3 17.1 17.3 18.2 17.7 18.6 18.8 19.6 19.8 20.7 20.2 21.1 21.2 22.2 22.2 23.2 22.6 23.6 23.7 24.7 10.0 10.7 11.4 10.4 11.1 11.8 11.3 12.0 12.8 12.5 13.3 14.1 13.0 13.7 14.5 13.9 14.7 15.5 14.8 15.6 16.5 15.2 16.1 16.9 16.1 17.0 17.9 17.0 17.9 18.9 17.4 18.4 19.3 18.4 19.3 20.3 19.3 20.2 21.2 19.7 20.7 21.7 20.6 21.6 22.6 1.85kg 3.00kg 11.0 11.8 11.4 12.2 12.3 13.1 13.1 13.9 13.5 14.4 14.4 15.2 15.2 16.1 15.6 16.5 16.4 17.4 17.3 18.3 17.7 18.7 18.5 19.6 10.6 11.4 11.4 12.2 11.8 12.7 12.6 13.5 13.4 14.3 13.8 14.7 14.5 15.5 15.3 16.3 15.7 16.7 1000 16.5 17.5 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate Weights 3mm 316 Stainless Steel Casings, 150mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 5.6 6.8 7.5 8.4 9.3 150 6.4 7.7 8.3 9.3 10.3 200 7.2 8.5 9.1 250 8.0 9.4 10.0 300 8.8 350 9.6 400 10.4 450 500 550 600 650 14.5 16.1 16.7 18.1 19.4 20.0 21.4 23.1 23.7 25.0 26.4 27.0 28.3 29.7 30.3 31.7 33.0 33.6 35.0 700 15.3 17.0 17.6 18.9 20.3 20.9 22.3 24.0 24.7 26.1 27.4 28.1 29.4 30.8 31.4 32.8 34.2 34.8 36.2 750 16.1 17.8 18.4 19.8 21.2 21.9 23.3 25.0 25.7 27.1 28.5 29.1 30.5 31.9 32.6 34.0 35.4 36.0 37.4 800 16.9 18.6 19.3 20.7 22.2 22.8 24.2 26.0 26.6 28.1 29.5 30.2 31.6 33.1 33.7 35.2 36.6 37.2 38.7 3.00kg 3.50kg 850 900 950 1000 20.1 22.0 22.6 24.2 25.8 26.4 28.0 30.0 30.6 32.2 33.8 34.4 36.0 37.6 38.2 39.8 41.4 42.0 43.6 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 11.2 12.0 12.7 13.6 13.4 14.2 14.5 15.4 15.7 16.7 16.4 17.3 17.5 18.5 19.1 20.1 19.7 20.7 20.9 22.0 22.1 23.2 22.8 23.8 24.0 25.1 25.2 26.3 25.8 26.9 27.0 28.2 28.2 29.4 28.8 30.0 30.0 31.3 12.9 13.7 14.4 15.3 15.1 15.9 16.3 17.2 17.6 18.5 18.2 19.1 19.5 20.4 21.1 22.1 21.7 22.7 23.0 24.0 24.3 25.3 24.9 25.9 26.2 27.3 27.4 28.6 28.1 29.2 29.3 30.5 30.6 31.8 31.2 32.4 32.5 33.7 17.7 18.5 19.3 19.5 20.3 21.2 20.1 20.9 21.8 21.6 22.5 23.3 23.1 24.0 24.9 23.7 24.6 25.5 25.2 26.1 27.1 27.0 28.0 29.0 27.6 28.6 29.6 29.1 30.1 31.2 30.6 31.7 32.7 31.2 32.3 33.3 32.7 33.8 34.9 34.2 35.3 36.5 34.8 36.0 37.1 36.3 37.5 38.7 37.8 39.0 40.2 38.4 39.6 40.8 39.9 41.2 42.4 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 8.5 12.1 14.7 17.8 21.4 24.2 27.7 31.9 35.0 38.8 43.1 46.4 50.5 55.1 58.6 63.0 67.9 71.7 76.5 10.2 11.1 11.9 10.8 11.7 12.5 11.9 12.8 13.7 13.0 13.9 14.8 13.6 14.5 15.5 14.7 15.7 16.6 16.2 17.1 18.1 16.8 17.8 18.8 17.9 18.9 19.9 19.0 20.0 21.1 19.6 20.7 21.7 20.7 21.8 22.9 21.8 22.9 24.0 22.4 23.5 24.7 23.5 24.7 25.8 24.6 25.8 27.0 25.2 26.4 27.6 26.3 27.6 28.8 1.85kg 3.00kg 10.2 11.0 11.2 12.1 11.8 12.7 12.8 13.8 14.2 15.2 14.8 15.8 15.8 16.9 16.9 17.9 17.5 18.5 18.5 19.6 19.5 20.7 20.2 21.3 21.2 22.3 22.2 23.4 22.8 24.0 23.9 25.1 10.0 10.9 10.9 11.8 12.2 13.2 12.8 13.8 13.8 14.8 14.7 15.8 15.4 16.4 16.3 17.4 17.3 18.4 17.9 19.0 18.9 20.0 19.8 21.0 20.4 21.6 1000 21.4 22.6 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate 14 www.actionair.co.uk A- 60 Marine Fire Dampers Weights 2mm Galvanised Casings, 210mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 4.8 5.9 6.4 7.3 8.1 8.6 9.5 150 5.5 6.6 7.1 8.0 8.9 9.4 10.3 200 6.1 7.3 7.9 8.8 9.7 250 6.8 8.1 8.6 9.5 10.5 300 7.5 8.8 9.3 350 8.2 9.5 400 8.9 10.2 450 9.5 500 10.2 550 600 650 12.3 13.8 14.3 15.5 16.7 17.2 18.4 20.0 20.5 21.7 22.9 23.5 24.7 25.9 26.4 27.6 28.8 29.4 30.6 700 12.9 14.5 15.0 16.2 17.5 18.0 19.2 20.8 21.4 22.6 23.9 24.4 25.6 26.9 27.4 28.7 29.9 30.4 31.7 750 13.6 15.2 15.7 17.0 18.3 18.8 20.0 21.7 22.2 23.5 24.8 25.3 26.6 27.9 28.4 29.7 30.9 31.5 32.7 800 14.3 15.9 16.4 17.7 19.0 19.6 20.9 22.5 23.1 24.4 25.7 26.2 27.5 28.8 29.4 30.7 32.0 32.5 33.8 3.00kg 3.50kg 850 900 950 1000 17.0 18.8 19.3 20.7 22.2 22.7 24.1 25.9 26.5 27.9 29.4 29.9 31.3 32.8 33.3 34.8 36.2 36.7 38.2 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 10.9 11.6 12.3 13.1 12.9 13.6 14.0 14.7 15.1 15.9 15.7 16.4 16.8 17.6 18.3 19.1 18.8 19.7 20.0 20.8 21.1 22.0 21.6 22.5 22.8 23.7 23.9 24.9 24.4 25.4 25.6 26.6 26.7 27.8 27.3 28.3 28.4 29.5 15.0 15.7 16.3 16.6 17.3 18.1 17.1 17.9 18.6 18.5 19.2 20.0 19.8 20.6 21.4 20.3 21.1 21.9 21.7 22.5 23.3 23.4 24.2 25.1 23.9 24.7 25.6 25.3 26.1 27.0 26.6 27.5 28.4 27.1 28.0 29.0 28.5 29.4 30.4 29.8 30.8 31.8 30.3 31.3 32.3 31.7 32.7 33.7 33.0 34.1 35.1 33.6 34.6 35.7 34.9 36.0 37.1 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 6.8 9.7 11.7 14.2 17.0 19.2 21.9 25.4 27.8 30.8 34.2 36.7 40.0 43.6 46.3 49.8 53.8 56.6 60.4 10.9 11.6 11.4 12.1 12.5 13.2 13.6 14.4 14.1 14.9 15.2 16.0 16.6 17.4 17.1 18.0 18.2 19.1 19.3 20.2 19.8 20.7 20.9 21.8 22.0 22.9 22.5 23.5 23.6 24.6 24.6 25.7 25.2 26.2 26.2 27.3 10.0 10.7 10.3 11.0 11.8 11.2 12.0 12.8 11.8 12.5 13.3 12.7 13.5 14.3 14.0 14.9 15.8 14.6 15.4 16.3 15.6 16.4 17.3 16.5 17.4 18.4 17.0 18.0 18.9 18.0 19.0 19.9 19.0 20.0 21.0 19.5 20.5 21.5 20.5 21.5 22.6 21.5 22.5 23.6 22.0 23.1 24.1 23.0 24.1 25.2 1.85kg 3.00kg 10.2 11.0 11.1 11.9 12.4 13.2 12.9 13.7 13.8 14.7 14.7 15.6 15.2 16.1 16.1 17.1 17.0 18.0 17.6 18.6 18.5 19.5 19.4 20.4 19.9 21.0 20.8 21.9 10.7 11.5 11.2 12.0 12.0 12.9 12.9 13.8 13.4 14.3 14.2 15.2 15.1 16.1 15.6 16.6 16.5 17.5 17.3 18.3 17.8 18.9 1000 18.7 19.7 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate Weights 3mm Galvanised Casings, 210mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 6.5 7.9 8.7 9.8 150 7.5 8.9 9.7 10.8 200 8.4 9.9 250 9.4 10.8 300 350 400 450 500 550 600 650 16.9 18.6 19.4 20.8 22.3 23.0 24.5 26.3 27.0 28.5 30.0 30.7 32.2 33.6 34.4 35.8 37.3 38.1 39.5 700 17.8 19.6 20.4 21.8 23.3 24.1 25.5 27.4 28.2 29.6 31.1 31.9 33.4 34.9 35.6 37.1 38.6 39.4 40.9 750 18.7 20.6 21.3 22.8 24.4 25.1 26.6 28.5 29.3 30.8 32.3 33.1 34.6 36.1 36.9 38.4 39.9 40.7 42.2 800 19.7 21.5 22.3 23.8 25.4 26.2 27.7 29.6 30.4 31.9 33.5 34.2 35.8 37.4 38.1 39.7 41.2 42.0 43.5 3.00kg 3.50kg 850 900 950 1000 23.4 25.4 26.2 27.9 29.6 30.3 32.0 34.0 34.8 36.5 38.2 38.9 40.6 42.3 43.1 44.8 46.5 47.2 48.9 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 10.3 11.2 12.2 11.8 12.8 13.8 12.6 13.5 14.5 13.8 14.8 15.8 15.0 16.0 17.1 15.7 16.8 17.8 16.9 18.0 19.1 18.5 19.6 20.7 19.3 20.4 21.5 20.5 21.7 22.8 21.7 22.9 24.1 22.5 23.7 24.8 23.7 24.9 26.1 24.9 26.2 27.4 25.7 26.9 28.2 26.9 28.2 29.5 28.1 29.4 30.8 28.9 30.2 31.5 30.1 31.5 32.8 1.85kg 3.00kg 13.1 14.0 14.7 15.7 15.5 16.5 16.8 17.8 18.1 19.2 18.9 19.9 20.2 21.2 21.8 23.0 22.6 23.7 23.9 25.1 25.3 26.4 26.0 27.2 27.3 28.5 28.7 29.9 29.4 30.7 30.7 32.0 32.1 33.4 32.8 34.1 34.1 35.5 15.0 15.9 16.7 17.6 17.4 18.4 18.8 19.8 20.2 21.2 21.0 22.0 22.3 23.4 24.1 25.2 24.8 25.9 26.2 27.4 27.6 28.8 28.4 29.5 29.8 31.0 31.1 32.4 31.9 33.1 33.3 34.6 34.7 36.0 35.4 36.7 36.8 38.2 20.6 21.6 22.5 22.5 23.5 24.5 23.3 24.2 25.2 24.9 25.9 26.9 26.4 27.5 28.5 27.2 28.2 29.3 28.8 29.8 30.9 30.7 31.8 32.9 31.5 32.6 33.7 33.1 34.2 35.4 34.7 35.8 37.0 35.4 36.6 37.8 37.0 38.2 39.4 38.6 39.8 41.1 39.4 40.6 41.8 40.9 42.2 43.5 42.5 43.8 45.2 43.3 44.6 45.9 44.9 46.2 47.6 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 9.4 13.2 16.1 19.4 23.2 26.3 30.0 34.4 37.8 41.8 46.2 49.7 54.1 58.8 62.5 67.2 72.2 76.2 81.2 10.6 11.6 11.8 12.8 12.9 14.0 13.7 14.7 14.8 15.9 16.3 17.4 17.1 18.2 18.2 19.4 19.4 20.6 20.1 21.3 21.3 22.5 22.4 23.7 23.2 24.4 24.4 25.6 25.5 26.8 26.3 27.6 27.4 28.8 10.8 11.9 11.6 12.6 12.7 13.7 14.1 15.2 14.9 16.0 15.9 17.1 17.0 18.2 17.8 19.0 18.9 20.1 20.0 21.2 20.7 22.0 21.8 23.1 22.9 24.2 23.7 25.0 1000 24.7 26.1 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate www.actionair.co.uk 15 A- 60 Marine Fire Dampers Weights 2mm 316 Stainless Steel Casings, 210mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 4.8 6.0 6.5 7.4 8.2 8.7 9.6 150 5.5 6.7 7.2 8.1 9.0 9.5 10.4 200 6.2 7.4 8.0 8.9 9.8 250 6.9 8.2 8.7 9.6 10.6 300 7.6 8.9 9.4 350 8.3 9.6 400 9.0 10.4 450 9.7 500 10.4 550 600 650 12.4 14.0 14.5 15.8 17.0 17.5 18.8 20.4 20.9 22.1 23.4 23.9 25.2 26.4 26.9 28.2 29.4 30.0 31.2 700 13.1 14.7 15.2 16.5 17.8 18.3 19.6 21.2 21.8 23.1 24.3 24.9 26.2 27.4 28.0 29.2 30.5 31.1 32.3 750 13.8 15.4 16.0 17.3 18.6 19.1 20.4 22.1 22.6 24.0 25.3 25.8 27.1 28.4 29.0 30.3 31.6 32.1 33.5 800 14.5 16.2 16.7 18.0 19.4 19.9 21.3 23.0 23.5 24.9 26.2 26.7 28.1 29.5 30.0 31.3 32.7 33.2 34.6 3.00kg 3.50kg 850 900 950 1000 17.3 19.1 19.6 21.1 22.6 23.1 24.6 26.5 27.0 28.5 30.0 30.5 32.0 33.5 34.0 35.5 37.0 37.6 39.1 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 11.1 11.7 12.5 13.3 13.1 13.8 14.2 15.0 15.4 16.2 15.9 16.7 17.1 17.9 18.6 19.5 19.2 20.0 20.3 21.2 21.5 22.4 22.0 23.0 23.2 24.2 24.4 25.4 24.9 25.9 26.1 27.1 27.3 28.4 27.8 28.9 29.0 30.1 15.2 15.9 16.6 16.9 17.6 18.4 17.4 18.2 18.9 18.8 19.6 20.3 20.2 21.0 21.8 20.7 21.5 22.3 22.1 22.9 23.8 23.8 24.7 25.6 24.4 25.2 26.1 25.8 26.7 27.6 27.2 28.1 29.0 27.7 28.6 29.6 29.1 30.1 31.0 30.5 31.5 32.5 31.0 32.0 33.0 32.4 33.4 34.5 33.8 34.9 35.9 34.3 35.4 36.5 35.7 36.8 37.9 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 6.9 9.8 11.9 14.4 17.3 19.5 22.3 25.9 28.3 31.3 34.8 37.4 40.7 44.5 47.2 50.9 55.9 57.8 61.7 11.1 11.8 11.6 12.3 12.7 13.5 13.8 14.6 14.3 15.1 15.4 16.2 16.9 17.8 17.4 18.3 18.5 19.4 19.6 20.6 20.1 21.1 21.3 22.2 22.4 23.4 22.9 23.9 24.0 25.1 25.1 26.2 25.6 26.7 26.7 27.9 10.2 10.9 10.4 11.2 11.9 11.4 12.2 13.0 11.9 12.7 13.5 12.9 13.7 14.6 14.3 15.1 16.0 14.8 15.7 16.5 15.8 16.7 17.6 16.8 17.7 18.7 17.3 18.3 19.2 18.3 19.3 20.3 19.3 20.3 21.4 19.8 20.9 21.9 20.9 21.9 23.0 21.8 22.9 24.0 22.4 23.5 24.5 23.4 24.5 25.6 1.85kg 3.00kg 10.3 11.1 11.2 12.1 12.5 13.4 13.1 13.9 14.0 14.9 14.9 15.9 15.4 16.4 16.4 17.4 17.3 18.3 17.8 18.8 18.8 19.8 19.7 20.8 20.2 21.3 21.1 22.3 10.8 11.7 11.3 12.2 12.2 13.1 13.0 14.0 13.6 14.5 14.4 15.4 15.3 16.3 15.8 16.8 16.7 17.7 17.5 18.6 18.0 19.1 1000 18.9 20.0 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate Weights 3mm 316 Stainless Steel Casings, 210mm Deep Calculated Weights (kg) of A-60 Rectangular (Excluding Actuator) 100 100 150 200 250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 6.6 8.0 8.8 9.8 150 7.6 9.0 9.7 10.9 200 8.5 250 9.5 300 350 400 450 500 550 600 650 17.1 18.9 19.6 21.1 22.6 23.3 24.8 26.7 27.4 28.9 30.4 31.2 32.7 34.2 34.9 36.4 37.9 38.7 40.2 700 18.0 19.8 20.6 22.1 23.6 24.4 25.9 27.8 28.6 30.1 31.6 32.4 33.9 35.4 36.2 37.7 39.3 40.0 41.6 750 19.0 20.8 21.6 23.1 24.7 25.5 27.0 28.9 29.7 31.3 32.8 33.6 35.1 36.7 37.5 39.0 40.6 41.4 42.9 800 19.9 21.8 22.6 24.2 25.8 26.5 28.1 30.1 30.8 32.4 34.0 34.8 36.4 38.0 38.7 40.3 41.9 42.7 44.3 3.00kg 3.50kg 850 900 950 1000 23.7 25.8 26.5 28.3 30.0 30.8 32.5 34.6 35.3 37.1 38.8 39.6 41.3 43.1 43.8 45.6 47.3 48.1 49.8 Calculated Weights (kg) of A-60 Circular (Excluding Actuator) 10.4 11.4 12.3 11.9 12.9 13.9 12.7 13.7 14.7 13.9 15.0 16.0 15.2 16.2 17.3 15.9 17.0 18.1 17.2 18.3 19.3 18.8 19.9 21.0 19.5 20.7 21.8 20.8 21.9 23.1 22.0 23.2 24.4 22.8 24.0 25.2 24.0 25.3 26.5 25.2 26.5 27.8 26.0 27.3 28.6 27.3 28.6 29.9 28.5 29.8 31.2 29.3 30.6 32.0 30.5 31.9 33.3 1.85kg 3.00kg 13.3 14.2 14.9 15.9 15.7 16.7 17.0 18.0 18.3 19.4 19.1 20.2 20.4 21.5 22.1 23.3 22.9 24.0 24.3 25.4 25.6 26.8 26.4 27.6 27.7 29.0 29.1 30.3 29.8 31.1 31.2 32.5 32.5 33.9 33.3 34.6 34.6 36.0 15.2 16.1 16.9 17.9 17.7 18.6 19.1 20.1 20.5 21.5 21.2 22.3 22.6 23.7 24.4 25.5 25.2 26.3 26.6 27.8 28.0 29.2 28.8 30.0 30.2 31.4 31.6 32.9 32.4 33.7 33.8 35.1 35.2 36.6 36.0 37.3 37.4 38.8 20.9 21.8 22.8 22.8 23.8 24.8 23.6 24.6 25.5 25.2 26.2 27.2 26.8 27.9 28.9 27.6 28.6 29.7 29.2 30.3 31.4 31.2 32.3 33.5 32.0 33.1 34.2 33.6 34.8 35.9 35.2 36.4 37.6 36.0 37.2 38.4 37.6 38.9 40.1 39.3 40.5 41.8 40.0 41.3 42.6 41.7 43.0 44.3 43.3 44.6 46.0 44.1 45.4 46.7 45.7 47.1 48.4 100 Dia. 150 Dia. 200 Dia. 250 Dia. 300 Dia. 350 Dia. 400 Dia. 450 Dia. 500 Dia. 550 Dia. 600 Dia. 650 Dia. 700 Dia. 750 Dia. 800 Dia. 850 Dia. 900 Dia. 950 Dia. 1000 Dia. 9.6 13.4 16.3 19.7 23.5 26.7 30.4 35.0 38.4 42.4 47.0 50.6 55.0 59.8 63.6 68.4 73.5 77.7 82.7 10.0 11.0 10.7 11.7 11.9 12.9 13.1 14.1 13.8 14.9 15.0 16.1 16.5 17.6 17.3 18.4 18.4 19.6 19.6 20.8 20.4 21.6 21.5 22.8 22.7 24.0 23.5 24.7 24.6 26.0 25.8 27.2 26.6 27.9 27.7 29.1 10.9 12.0 11.7 12.8 12.8 13.9 14.2 15.4 15.0 16.1 16.1 17.3 17.2 18.4 18.0 19.2 19.1 20.3 20.2 21.4 20.9 22.2 22.0 23.3 23.1 24.5 23.9 25.2 1000 25.0 26.4 Compact Universal Including Adaptor Plate Including Adaptor Plate Pneumatic Including Adaptor Plate Electrical Atex Including Adaptor Plate 16 www.actionair.co.uk A- 60 Marine Fire Dampers Acoustic Data The data presented is from the Laboratory Determination of Acoustic and Aerodynamic Performance of A-60 Marine Fire Dampers. A programme of extensive tests was carried out by an independent test facility, approved under the NAMAS Scheme, in accordance with BRITISH STANDARDS Nos. 4196, 4773, 4856, 4857 and 4954. From the selection of a duct velocity within the operational parameters of the damper a resultant pressure drop from Table 1 can be determined and the sum of these two components applied to the Velocity x Pressure Drop Vs Sound Power Level Graph. (Table 2). The graph is the result of a full range of acoustic tests with the blades set in the fully open position. The Spectrum Correction Data is applied to the number obtained from the graph and a complete Sound Spectrum of Flow Generated Noise for both Outlet (in duct) and Breakout (casing radiated) is obtained. Example: Duct with a design velocity of 8 m/sec and the A-60 Marine Fire Damper RECT damper blades in the fully open position. Pressure Drop = 22 Pa (Table 1). Multiply Velocity x Pressure Drop 8 x 22 = 176. From Sound Power Graph (Table 2) plot 176 on horizontal Velocity/Pressure axis against the A-60 Marine Fire Damper RECT outlet (induct) graph to obtain 47 dBW on Vertical Sound Power Level Axis. Add or subtract corrections to the 47dBW to provide full spectrum analysis. Damper Leakage Table 3 A-60 Marine Fire Damper damper closed blade leakage. Standard (without blade seals) Optional (with blade seals) 1500 1000 500 DIFFERENTIAL PRESSURE (Pa) 100 10 1 10 50 100 200 LEAKAGE (I/s per m2) Pressure Drop Vs Velocity Table 1 100 90 80 70 60 50 40 Velocity (m/s) X Pressure Drop (Pa) Vs Sound Power Level (dBW) Table 2 90 80 CT ) 70 30 SOUND POWER LEVEL (dBW) EXAMPLE LINE 20 A-6 0R EC T 60 A- C 60 I RC OU TL E IN T( DU PRESSURE DROP (Pa) A-6 0C IRC A-6 0 C RE TO UT L ( ET IND UC T) 50 EXAMPLE LINE 10 9 8 7 6 5 4 3 2 40 EC R TB EA KO UT 30 A-6 0R 20 A-6 0C IR R CB EA KO UT 10 1 1 2 3 4 5 6 7 8 9 10 15 0 4000 5000 6000 7000 8000 9000 10000 400 500 600 700 800 900 1000 40 50 60 70 80 90 100 2000 3000 200 300 10 20 30 VELOCITY (m/s) VELOCITY X PRESSURE DROP (m/s Pa) Outlet (Induct) Spectrum Corrections Octave Band63 125 250 500 1k 2k 4k 8k A-60 RECT 5 4 5 5 3 1 -3 -5 A-60 CIRC 944 5 3 1 -3 -6 Breakout Spectrum Corrections 63 125 250 500 1k 2k 4k 8k Hz 8 11 9 6 -3 -6 -14 -17 dB 6 10 8 4 -3 -3 -11 -14 dB www.actionair.co.uk 17 A- 60 Marine Fire Dampers Visual Indication Visual indication non drive side Option to have drive blade visual indication, non drive side only. Red indicates damper closed Green indicates damper open. Damper Release and Indication Module Damper Release and Indication Module (DRIM) This is designed for control and monitoring of the electrically operated A-60 Marine Fire Dampers. It will operate from 24, 120 or 230 volt supplies, 50 or 60 Hz. Selection of the operating voltage is by use of internal links on the PCB, prior to installation and connection of actuator and supply. The DRIM may be used singly to provide local damper control, or in pairs to provide control from either side of a damper. It can also operate 2 actuators when dampers are provided in 2 multiple sections LED position and operation indication is provided. Operation is by push button to close and twist to re-open damper. Tested to BS EN 61010 -1: 2001 and is CE compliant. IP44 rated. Operating range 5 - 40 degrees C. 18 www.actionair.co.uk A- 60 Marine Fire Dampers Standard Ordering Procedure Please Specify Series A- 60 RECT(Galv) A- 60 Marine Fire Damper 430 Ferritic Stainless Steel Blades Square or Rectangular Flanges Galvanised Casing 1.2, 2 or 3mm Casing A- 60 CIRC (Galv) A- 60 Marine Fire Damper 430. Ferritic Stainless Steel Blades. Circular Flanged. Galvanised Casing. 1.2, 2 or 3mm Casing. A- 60 RECT (316) A- 60 Marine Fire Damper 316 Austenitic Stainless Steel Blades. Square or Rectangular Flanges. Stainless Steel Casing. 1.2, 2 or 3mm Casing. A- 60 CIRC (316) A- 60 Marine Fire Damper 316. Austenitic Stainless Steel Blades. Circular Flanged. Stainless Steel Casing. 1.2, 2 or 3mm Casing. Control Modes Electric Control Mode 5 24V A.C. or D.C. Electric Control Mode 6 230V A.C. 50/60Hz Electric Control Mode 120 120V A.C. 50/60Hz Pneumatic 5 - 8 Bar Air Supply Electrical Atex Universal voltage. Seals Standard (without blade seals) Optional (with blade seals) Visual Indication - Non drive side Casing Thickness 1.2, 2 or 3mm Flange Holes Drilled (Standard) Undrilled (Optional) Customer Drilling (Optional) Casing Depth 150 or 210mm (210 in 2 or 3mm only) Part Number Accessories (Electrical) Damper Release and Indication Module Push off, Twist on, for control and monitoring Damper Connection Box Galvanised Mild Steel (DCB24) 120/230 24, 120 or 230V 24 - 230V AC XNNN00588 XNNN00312 ETR Probe DNNN00359 Accessories (ATEX Electrical) Atex Ex Rated Safety Temperature Sensor (STS) MNNN00141 Manual Override Handwheel XNNN00579 EX Rated Auxiliary Switches XNNN00577 Ex Rated Terminal Box XNNN00578 Accessories (Pneumatic) Solenoid, (24, 120, or 230 volt). Switchbox (Status Beacon). PTR Example 3 / A-60 RECT (Galv) I I Quantity Series -- -- XNNN05017 / 1.2mm / 150mm I I Thickness Depth / 400 (W) x 250 (H) / M5 / Standard I I I Duct size Control Modes Seals / Customer I Flange Holes / DRIM I Accessories www.actionair.co.uk 19 A- 60 Marine Fire Dampers Ruskin Air Management Limited a BS EN ISO 9000 registered company The statements made in this brochure or by our representatives in consequence of any enquiries arising out of this document are given for information purposes only. They are not intended to have any legal effect and the company is not to be regarded as bound thereby. The company will only accept obligations which are expressly negotiated for and agreed and incorporated into a written agreement made with its customers. Due to a policy of continuous product development the specification and details contained herein are subject to alteration without prior notice. Ruskin Air Management Limited South Street, Whitstable, Kent CT5 3DU England. Tel: 01227 276100 Fax: 01227 264262 Email: sales@actionair.co.uk Website: www.actionair.co.uk");sQ1[87]=new Array("http://www.actionair.co.uk/marineapps1.htm","MARINE APPLICATIONS","","A-60 MARINE FIRE DAMPER FOR MARINE APPLICATIONS     A-60 Marine Damper Series Lloyds Register of Shipping Approval to IMO Fire Test Procedures Code, Annex 1, Part 3. The Actionair A60 range fulfils all the requirements of the Marine Equipment Directive (MED). In addition, under the Mutual Recognition Agreement (MRA) it fulfils all the requirements of the United States Coastguard (USCG). The A60 range is available in galvanised mild steel or stainless steel materials and is generally more compact and lighter than units traditionally meeting the MED that are supplied by other manufacturers. All actuators offered have been fire tested in conjunction with the dampers during certification. The units are tested and approved for class A-60 divisions (bulkheads and decks) with a minimum length as per brochure.  The “Wheelmark”, showing the MED and USCG certificate numbers Actionair uses Lloyds as a notified body for the A-60 Marine Damper product. This means that Lloyds regularly inspect our products and our manufacturing procedures to ensure that we manufacture the product in line with the tests that Actionair have undertaken. They also hold details of any assessments we may have on the product that have been agreed by them. The products have full Module B EC type examination approval, backed up by Module D Procedural Quality assurance Approval. This means that the “Wheelmark” may be applied, giving you complete peace of mind in using a fully tested, fully certificated, life safety product that meets all the requirements of the MED. Sizes 100 x 100 – 1000 x 1000 (Single section), 1580 x 750 (multiple sections) For other multiple sections, please contact the sales office  Having certification to the MED means that by law the product is universally acceptable across Europe. Further certification from other notified or legislative bodies is not necessary. The whole concept of the MED is to remove this potential barrier to trade, i.e. providing that certification has been provided by a notified body, products may be offered for sale throughout the EU. In this way, the “Wheelmark” is similar to the CE marking in other areas of product supply. If you still have problems with a client or perhaps meeting a specification, the above should be pointed out to a client or customer. If this still proves difficult, the specific Certifying Organisation or Legislative Body whose approval is required should be approached directly with the explanation that the product proposed is “Wheelmarked”. If this still does not work, then the matter should be taken further with a trading standards or local government officer. Similarly, Having USCG approval under the MRA means that the product is universally acceptable across the United States and the world for vessels needing USCG approved products to be used in their construction. Actuators 24V(ac or dc), 120V(ac), 230V(ac), pneumatic options - To prevent damage in transit, the actuators are shipped separately, but have a special interface to allow them to be fitted to the dampers very simply. Downloads A-60 Marine  - Catalogue A-60 Marine - Installation, Operation and maintenance Instructions – Electrical A-60 Marine - Installation, Operation and maintenance Instructions – Pneumatic Links Marine Equipment Directive (MARED) Lloyds USCG Germanischer Lloyds A60 Certificate  Marine Mist Eliminators A range of mist eliminators for marine applications has been developed from the NACO range of Storm Louvres. They are suitable for such applications as engine air intake louvres are up to 98% efficient. They are robustly constructed form aluminium extrusions and may be made to drain outwards or in to an integral sump for bilge collection. Downloads Marine Mist Eliminator datasheet Marine Mist Eliminator – Performance chart Our Mission Actionair, as part of Ruskin Air Management Limited, is committed to providing innovative solutions for smoke control and waterside control fan coil units through the pursuit of excellence. Home | Search | Products | Catalogues | Contact Copyright © 2006 actionair. All Rights Reserved RAM | Air Diffusion | Naco | Minimum system requirements | Lega l &nbsp;");sQ1[88]=new Array("http://www.actionair.co.uk/datasheets_o&m/O&M/A-60%20PNEUMATIC%20O%20&%20M%20June%202006.pdf","Microsoft Word - A-60 O+M elec June 2006.doc","","June 2006 A-60 Marine Fire Damper Installation, Operating & Maintenance Instructions Description The A-60 Marine Fire Damper is tested and approved for fitting to class A-60 divisions (bulkheads and decks), when suitably insulated (see page 2 for details). Tests and Approvals A60 Fire Rated. Lloyds Register of Shipping Approved. Marine Equipment Directive Compliant. USCG Approved. Germanischer Lloyds Approved. American Bureau of Shipping Approved. Corrosion Tested. Vibration Tested. The A-60 Marine Fire Damper is designed for inclusion in air conditioning and ventilation systems. YY Denotes last two digits of year the Wheelmark is affixed to damper Health and Safety All wiring should be carried out in accordance with the wiring details provided, to the IEC regulations. Larger dampers are heavy and must be handled in accordance with current regulations and good practice) Care must be taken when installing and inspecting dampers, as they are likely to close without warning due to loss of electrical power, or a temperature rise in the ductwork. This is their prime function. Do not introduce any items, fingers or limbs between the blades. General Information The A-60 Marine Fire Damper is suitable for both vertical and horizontal applications, with airflow in either direction. The dampers which are A60 fire rated to IMO fire test procedures Code, Annex 1 Pt 3, are normally open, and failsafe to the closed position. The A-60 Marine Fire Dampers are supplied with the blades in the fully interlocked closed position to avoid damage during transit and installation. It is recommended that the dampers remain closed until actual date of commissioning. All fire dampers are life safety products and should be treated with care during handling, storage and installation. A-60 Marine Fire Dampers are designed for applications in normal dry filtered air systems and should be subjected to a planned inspection programme, with cleaning and light oil lubrication in accordance with good industry practice. When exposed to fresh air intakes and/or inclement conditions this may need to be performed more regularly based on experience gained from previous inspections. Page 2 www.actionair.co.uk www.actionair.co.uk A-60 Marine Fire Damper Damper installation All installations must be carried out in accordance with the relevant Marine/Offshore Authority requirements. The damper should be installed in accordance with Insulation details (as shown) that represents a typical A60 installation. Bolt holes are provided as standard on the damper flanges (unless otherwise stated) at 150mm maximum centres. Matching hole positions are necessary on mating coaming/duct flanges. Apply approved fire resistant sealant/gasket to mating flanges and position damper. Bolt damper using M8 minimum diameter steel bolts, at a maximum of 200mm centres. Note: For vertical applications, the 50mm casing dimension (see below) should be uppermost. Insulation Details: Multiple arrangements: Optional Page 2 www.actionair.co.uk Control Modes Two sizes of Control Mode (Compact & Universal) are utilised. Correctly sized Control Modes are designed to fit only to the relevant sized damper. (See `Control Mode Standard Parameters' figure) 1. Three position (Refer to figs 1 and 2) 1.1. Remove transit plate from damper mounting plate, and discard. 1.2. Fit adaptor plate to Control Mode. 1.3. Position Control Mode onto mounting bracket. Secure with screw & washer provided. Tighten to 5Nm. It is important that the Control Mode is fitted with the product label denoting &quot;fail safe close&quot; is facing outermost; otherwise the assembly will not operate as designed 2. Single Position (Refer to fig 3) 2.1 Remove transit plate from damper mounting plate, and discard. 2.2 Position Control Mode onto mounting bracket as Fig 3. Secure with screws provided. It is important that the Control Mode is fitted with the product label facing outermost; otherwise the assembly will not operate as designed Mechanical Operation check As an interim check, the damper should be manually reset and released using the manual reset key provided, (refer to Control Mode label) to ensure that correct mechanical operation is achieved. This feature may be used for system commissioning when electrical power is unavailable. Note however, the ETR is not operable without electrical power, and the damper will not close automatically should a temperature rise or fire occur. Electrical Thermal Release (ETR) Installation 1 Select a suitable position for the ETR on the duct as follows: 1.1 Deck Installations ­ Must be anywhere below the damper. 1.2 Bulkhead installations ­ Ideally this should be anywhere in the top half of the duct. Position the self-adhesive fusible link drilling template label provided in the appropriate position on the duct. Using a 3.0mm dia bit, drill the two ETR fixing holes. Using a 10mm dia drill, drill the central hole. Remove sharp edges. Push the ETR through the duct and ensure that both screws are used to hold it securely in position. 2 3 4 5 6 If the ETR is not fitted to the ductwork, the actuator will not operate. The ETR cable must not be shortened, and care must be taken not to damage it. Either of these actions will render the actuator inoperable. This is a built in safety feature. Electrical Connection and Final Operational Test The unit must be wired as described in the Application and Wiring section, page 4. When power is available, the unit must be checked for electrical operation. Power on to motor open, power off to spring close. The unit must also be checked by pushing and holding the test switch on the ETR to confirm that the damper closes. When pressure is removed from the switch the damper will re-open. This may be done after the initial installation test, to provide periodic operation of the damper - to simulate actual fail-safe closure under fire conditions. Note: Application of supply voltage will automatically override the manual locking mechanism Electrical Thermal Release (ETR) A green `Healthy' indication lamp is built into the ETR housing to give a simple and clear visual check that The actuator is receiving power The ETR is correctly fitted The thermal fuse is intact A manual test switch allowing periodic operation of the damper for testing purposes simulates actual failsafe release under smoke/fire conditions. End switches are provided with each Mode for reset and release monitoring. Page 3 www.actionair.co.uk Mode 5 Application and wiring Control Mode 5 24V A.C. or D.C. Control Mode 6 230V A.C. 50/60Hz Control Mode 120120V A.C. 50/60Hz Power On­ Damper motors open. Power Off­Damper springs closed. ETR Operates­Damper springs closed. Release Time 20 seconds. Reset Time = less than 60 seconds. End Switches Rated at 250V 1.5 Amp (Maximum). To isolate from main power supply, the system must incorporate a device, which disconnects the phase conductors, with at least 3mm contact gap. 2 x 1 metre of halogen free, low smoke and fume electric cables are included with each Control mode. The ETR is also pre-wired with 0.5 metre halogen free low smoke and fume cable. Mode 6 & Mode120 + SUPPLY 24v A.C. OR D.C. TYPICALLY 10W (MOTORING) 2W (RESET) CONTACT MADE BETWEEN 1 & 2 WHEN DAMPER FULLY RELEASED CONTACT MADE BETWEEN 4 & 6 WHEN DAMPER FULLY RESET ELECTRICAL THERMAL RELEASE (MUST BE FITTED FOR DAMPER OPERATION) (SPRING BIASED TEST SWITCH) DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE SUPPLY 230V A.C. / 120V A.C. TYPICALLY 12W (MOTORING) 4W (RESET) CONTACT MADE BETWEEN 1 & 2 WHEN DAMPER FULLY RELEASED CONTACT MADE BETWEEN 4 & 6 WHEN DAMPER FULLY RESET ELECTRICAL THERMAL RELEASE (MUST BE FITTED FOR DAMPER OPERATION) (SPRING BIASED TEST SWITCH) Troubleshooting Fault Control Mode does not fit damper Control Mode does not fit to damper drive shaft when Control Mode is correctly positioned Possible problem Two sizes of Control mode, and three bracket variants exist. Damper shaft not in `damper closed' position Control Mode not in released position DIAGRAM SHOWS ACTUATOR IN FULLY RELEASED STATE Recommended action Check correct selection (page 3) Damper shaft has an `indication groove' which is parallel to damper blades. Damper must be in closed position before fitting Control mode. If not electrically connected, check manual reset mechanism is released. (Refer to Control Mode label). If electrically powered, with ETR fitted, press and hold test switch on ETR. Refer to Page 3. Refer to above wiring diagram Remove probe section of ETR. Check electrical continuity of ETR probe, replace if necessary. Universal: Label must be outermost. Check and correct if nece
