EMS Control Panel



Actionpac Electro Mechanical Smoke and Fire Damper Control System.





Actionpac 60/120 fascia detail
Panel Fascia Detail
 
 

Actionair Actionpac EMS – Standard
Control and Monitoring System


Electro - Mechanical Standard (EMS)


The range of Actionpac Electro-Mechanical Standard (EMS) control panels are designed for the control and monitoring of either Mode 5 (24V) or Mode 6 (230V) PTC damper actuators in groups of 12, 24 or 36.

Damper control modes to be connected to the site wiring, which when installed by the contractors, shall provide the relevant standard functions.

Actionair offers a comprehensive after sales service to include for precommissioning checks, complete commissioning service of all our products in line with and to encompass CIBSE guidelines and planned preventive maintenance visits.

For greater number of dampers, refer to Actionair Actionpac EMB, LNS 60/120, or LNS3 Brochures.

Features

Catalogue
  • Damper control panels are standard manufacture
  • Wall mount enclosures to IP55
  • Vinyl overlay facia
  • Damper Controlled in zones and individually monitored
  • Top cable gland entry
  • Screwless cable terminators
  • Test/Normal/Override keyswitch
  • Keyswitch mains isolator
  • Lamp test
  • Hinged on right.
 


 







 


For more information including dimensional data please view the Actionpac EMS Catalogue Here

 

Specification for Actionpac EMS

The Actionair Actionpac EMS panels are of standard construction for the control and monitoring of Mode 5 or Mode 6 PTC damper actuators in groups of 12, 24 or 36 on printed circuit boards. Each group of 12 dampers are controlled and monitored via separated PCB’s, these will be numbered PCB 1 for dampers 1 to 12 and where fitted, PCB 2 for dampers 13 to 24 and PCB 3 for dampers 25 to 36.

The damper control PCB’s provide for screwless terminal blocks for all external connections to the dampers, Fire Alarms and BMS Contacts. Dampers are controlled in zones and monitored individually. Terminals provide for wiring all dampers individually. The damper status LED indication is provided by indicators PCB’s fitted in the door of the panel enclosure. Each indicator PCB provides for 12 PTC Actuators.

Damper locations can be recorded on a printed label fitted inside the enclosure door. Each Control PCB provides input terminals to accept 1 or 2 Volt free contact interfaces with the Fire Alarm System per group of 12 dampers (maximum of 6 dampers per zone). These connections should be Normally Closed (NC) going open circuit to indicate an alarm. In addition each control panel provides a single output terminal to provide a Volt free contact interface with a BMS. This is a changeover contact, which goes closed circuit to indicate either a non- normal or fault condition.


Actionpac EMS, as supplied by Actionair


 


Actionpac EMS - Standard  – Control and Monitoring System
Acrobat (PDF) Version
PDF Download Size = 950kb

     